Local characteristic of horizontal air-water two-phase flow by wire-mesh sensor

被引:4
作者
Liu, Weiling [1 ]
Tan, Chao [1 ]
Dong, Feng [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Tianjin Key Lab Proc Measurement & Control, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
3D transient flow fluctuation energy evolution; characteristic scale distribution; gas-liquid two-phase flow; local spectrum energy analysis; local void fraction distribution; wire-mesh sensor; ELECTRICAL CAPACITANCE TOMOGRAPHY; GAS-LIQUID FLOWS; PHASE DISTRIBUTION; VERTICAL PIPE; VOID FRACTION; BUBBLY FLOWS; SLUG FLOW; VISUALIZATION; DISTRIBUTIONS; PROBE;
D O I
10.1177/0142331216665689
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Two-phase flow widely exists in many industries. Understanding local characteristics of two-phase flow under different flow conditions in piping systems is important to design and optimize the industrial process for higher productivity and lower cost. Air-water two-phase flow experiments were conducted with a 16x16 conductivity wire-mesh sensor (WMS) in a horizontal pipe of a multiphase flow facility. The cross-sectional void fraction time series was analysed by the probability density function (PDF), which described the void fraction fluctuation at different flow conditions. The changes and causes of PDFs during a flow regime transition were analysed. The local structure and flow behaviour were characterized by the local flow spectrum energy analysis and the local void fraction distribution (horizontal, vertical and radial direction) analysis. Finally, three-dimensional transient flow fluctuation energy evolution and characteristic scale distribution based on wavelet analysis of air-water two-phase flow were presented, which revealed the structural features of each phase in two-phase flow.
引用
收藏
页码:746 / 761
页数:16
相关论文
共 46 条
  • [1] Two-Phase Upward Flow in a Slightly Deviated Pipe
    Abdulahi, Abolore
    Azzopardi, Barry J.
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (05):
  • [2] Detailed analysis of phase distributions in a vertical riser using wire mesh sensor (WMS)
    Abdulkadir, M.
    Hernandez-Perez, V.
    Lowndes, I. S.
    Azzopardi, B. J.
    Brantson, E. T.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 59 : 32 - 42
  • [3] [Anonymous], 1992, CBMS-NSF Reg. Conf. Ser. in Appl. Math
  • [4] [Anonymous], 2000, SUBSURF SENS TECH AP, DOI DOI 10.1023/A:1010118609079
  • [5] Capacitance wire mesh imaging of bubbly flows for offshore treatment applications
    Assima, Gnouyaro P.
    Larachi, Faical
    Schleicher, Eckhard
    Schubert, Markus
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 45 : 298 - 307
  • [6] Spatial distribution of void fraction in the liquid slug in the whole range of pipe inclinations
    Barnea, Dvora
    Roitberg, Elena
    Shemer, Lev
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2013, 52 : 92 - 101
  • [7] LOCAL PHASE DETECTION PROBES IN FLUID FLUID 2-PHASE FLOWS
    CARTELLIER, A
    ACHARD, JL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (02) : 279 - 303
  • [8] Application of the ultrasonic technique and high-speed filming for the study of the structure of air-water bubbly flows
    Carvalho, R. D. M.
    Venturini, O. J.
    Tanahashi, E. I.
    Neves, F., Jr.
    Franca, F. A.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (07) : 1065 - 1086
  • [9] Capacitance wire-mesh sensor for fast measurement of phase fraction distributions
    Da Silva, M. J.
    Schleicher, E.
    Hampel, U.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (07) : 2245 - 2251
  • [10] Phase fraction distribution measurement of oil-water flow using a capacitance wire-mesh sensor
    Da Silva, M. J.
    dos Santos, E. N.
    Hampel, U.
    Rodriguez, I. H.
    Rodriguez, O. M. H.