A STUDY FOR STARTING CHARACTERISTIC ANALYSIS METHOD OF SALIENT POLE SYNCHRONOUS MOTORS

被引:0
作者
Son, Rakwon [1 ]
Jeon, Moojong [2 ]
机构
[1] Hyundai Heavy Ind Co Ltd, Elect Elect Syst, Yongin, Gyeonggi Do, South Korea
[2] Hyundai Heavy Ind Co Ltd, Elect Elect Syst, Ulsan Si, South Korea
来源
2016 Petroleum and Chemical Industry Technical Conference (PCIC) | 2016年
关键词
Starting characteristic; Finite element method; Solid salient pole; Synchronous motor; Rotor core conductivity; Effective core length; End-leakage inductance;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Solid rotors can be adapted to synchronous motors of 5 MW and over in applications with high inertia loads. The eddy currents induced in the solid pole are used for starting of the motor and their paths are changed depending on the design of the rotor shape unlike the synchronous motors with damper windings or cages. In this paper, the starting characteristic of a 7 MW solid salient pole synchronous motor is analyzed by the combined methods for two and three-dimensional finite element models because a three-dimensional analysis to solve the problem is difficult due to the long solving time. The maximum difference between results of the combined method for two and three-dimensional finite element analysis and the factory test is less than 10%.
引用
收藏
页数:8
相关论文
共 9 条
  • [1] Alger P.L., 1951, NATURE POLYPHASE IND
  • [2] [Anonymous], 1152009 IEEE
  • [3] [Anonymous], 2013, MAXW 3D ONL HELP
  • [4] Boldea I., 2005, Synchronous Generators, DOI DOI 10.1201/9781420037258
  • [5] FRANKLIN PW, 1976, ADV THEORY DESIGN RO
  • [6] Li Y. B., 2009, IEEE T MAGNETICS, V45
  • [7] Lipo T.A., 2007, INTRO AC MACHINE DES
  • [8] Preston T. W., 1999, C PUBLICATION, V468
  • [9] Stranges N., 2008, POW EN SOC GEN M CON