Highly Sensitive Glucose Biosensor Based on One-Pot Biochemical Preoxidation and Electropolymerization of 2,5-Dimercapto-1,3,4-thiadiazole in Glucose Oxidase-Containing Aqueous Suspension

被引:25
作者
Fu, Yingchun [1 ]
Zou, Can [1 ]
Xie, Qingji [1 ]
Xu, Xiahong [2 ]
Chen, Chao [1 ]
Deng, Wenfang [1 ]
Yao, Shouzhuo [1 ,2 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ China, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Hunan, Peoples R China
[2] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
美国国家科学基金会;
关键词
O-AMINOPHENOL FILM; ONE-STEP; ELECTROCHEMICAL POLYMERIZATION; BIOCATALYTIC GENERATION; COMPOSITE BIOSENSOR; ELECTRODE SURFACES; AU-NANOPARTICLES; REDOX ENZYMES; IMMOBILIZATION; POLYPYRROLE;
D O I
10.1021/jp807337f
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel and high-performance biosensing platform was prepared on the basis of one-pot biochemical preoxidation and electropolymerization of monomer (BPEM) for high-load and high-activity immobilization of enzymes. As representative materials here, 2,5-dimercapto-1,3,4-thiadiazole (DMcT) was used as the monomer, glucose oxidase (GOx) was used as the model enzyme, and enzymatically generated H2O2 (EG-H2O2) in the presence of glucose was used as the preoxidant. In the BPEM protocol, glucose was added to a pH 7.0 phosphate buffer suspension containing ultrasonically dispersed DMcT and GOx, in order to enzymatically generate H2O2, which preoxidized DMcT to DMcT oligomers/polymer (DMcTO) and thus led to the formation of DMcTO-GOx composites with a great deal of GOx entrapped; the composites were then co-electrodeposited with poly(DMcT) on a Au electrode. For comparison, the enzyme immobilization was also conducted by a preoxidation-free conventional electropolymerization protocol (CEP), as well as a chemical preoxidation and electropolymerization of monomer (CPEM) protocol with externally added H2O2 (EA-H2O2) as the preoxidant. The glucose biosensors constructed by the BPEM and CPEM protocols exhibited detection sensitivities enhanced by 119 and 88 times, respectively, compared to that constructed by the CEP protocol, as well as limits of detection lowered by ca. 2 orders of magnitude. The higher sensitivity of the enzyme electrode prepared by the BPEM protocol compared to that prepared by the CPEM protocol is probably due to the improved proximity of biochemical preoxidation around the enzyme molecules and thus a larger enzyme load. The electrochemical quartz crystal microbalance technique was used to investigate various electrode modification processes, which also revealed that poly(DMcT) could be cathodically detached from the electrode surface, favorably enabling the electrochemical regeneration of the electrode substrate. The proposed BPEM strategy is recommended for wide biosensing and biocatalysis applications based on many other polymers/enzymes.
引用
收藏
页码:1332 / 1340
页数:9
相关论文
共 53 条
[21]   Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode [J].
Li, Jing ;
Lin, Xiangqin .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :2898-2905
[22]   Electrochemical quartz crystal impedance study on immobilization of glucose oxidase in a polymer grown from dopamine oxidation at an Au electrode for glucose sensing [J].
Li, Mingrui ;
Deng, Chunyan ;
Xie, Qingji ;
Yang, Yang ;
Yao, Shouzhuo .
ELECTROCHIMICA ACTA, 2006, 51 (25) :5478-5486
[23]   Self-assembled monolayers of thiolates on metals as a form of nanotechnology [J].
Love, JC ;
Estroff, LA ;
Kriebel, JK ;
Nuzzo, RG ;
Whitesides, GM .
CHEMICAL REVIEWS, 2005, 105 (04) :1103-1169
[24]   Electrochemically deposited nanocomposite of chitosan and carbon nanotubes for biosensor application [J].
Luo, XL ;
Xu, JJ ;
Wang, JL ;
Chen, HY .
CHEMICAL COMMUNICATIONS, 2005, (16) :2169-2171
[25]   A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition [J].
Luo, XL ;
Xu, JJ ;
Du, Y ;
Chen, HY .
ANALYTICAL BIOCHEMISTRY, 2004, 334 (02) :284-289
[26]   Glucose oxidase electrodes based on microstructured polypyrrole films [J].
Ma, MM ;
Qu, LT ;
Shi, GQ .
JOURNAL OF APPLIED POLYMER SCIENCE, 2005, 98 (06) :2550-2554
[27]   An electron-conducting cross-linked polyaniline-based redox hydrogel, formed in one step at pH 7.2, wires glucose oxidase [J].
Mano, Nicolas ;
Yoo, Joung Eun ;
Tarver, Jacob ;
Loo, Yueh-Lin ;
Heller, Adam .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (22) :7006-+
[28]   Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate [J].
McMahon, CP ;
Rocchitta, G ;
Serra, PA ;
Kirwan, SM ;
Lowry, JP ;
O'Neill, RD .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2352-2359
[29]   Polymer-enzyme composite biosensor with high glutamate sensitivity and low oxygen dependence [J].
McMahon, CP ;
O'Neill, RD .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :1196-1199
[30]   ELECTROCHEMISTRY OF DISULFIDE COMPOUNDS .1. ELECTROCHEMICAL POLYMERIZATION-DEPOLYMERIZATION PROCESS OF 2,5-DIMERCAPT-1,3,4-THIADIAZOLE [J].
NAOI, K ;
OURA, Y ;
IWAMIZU, Y ;
OYAMA, N .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (02) :354-360