Reliability of the motor evoked potentials elicited through magnetic stimulation at three sites

被引:13
作者
Lefebvre, R
Pépin, A
Louis, PF
Boucher, JP
机构
[1] Univ Quebec, Dept Kinanthropol, Montreal, PQ H3C 3P8, Canada
[2] Univ Quebec Trois Rivieres, Dept Chiroprat, Trois Rivieres, PQ GA9 5H7, Canada
关键词
motor evoked potential; electromyography; muscles; transcranial magnetic stimulation;
D O I
10.1016/j.jmpt.2003.12.004
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Motor evoked potentials (MEPs) obtained from magnetic stimulation allow the measurement of the excitability of motor nerve cells. Although this technique is becoming widely used, its reliability has yet to be established. Objective: To determine the reliability of MEPs and evaluate their stability. Design: Subjects received magnetic stimulation at 3 different sites: cranial, cervical, and peripheral. Three stimulations were given at each site. Stimulations were given under 4 conditions: eyes open or closed and with or without controlled mental activity. Setting: The study was performed in a research laboratory setting. Participants: Nine healthy subjects (mean age = 21 years +/- 0.9), asymptomatic of any neural or musculoskeletal dysfunctions. Main Outcome Measures: Normalized peak-to-peak amplitude of MEPs at the opponens pollicis muscle. Results: Intraclass correlations were high for all conditions (R > 0.90). The amplitude of the MEPs elicited from the transcranial site during the controlled mental activity condition was increased by 26.6% (P = .017). No other significant differences (P > .05) were obtained among the other conditions. Conclusion: Intraclass correlation results reveal that MEP measurements are highly reliable in a controlled environment. The increase of MEPs during the controlled mental activity condition could be attributed to an elevation of neural activity of different nonmotor areas of the brain increasing corticospinal excitability.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 23 条
  • [1] Andersen B, 1999, MUSCLE NERVE, V22, P857, DOI 10.1002/(SICI)1097-4598(199907)22:7<857::AID-MUS7>3.0.CO
  • [2] 2-B
  • [3] BARKER AT, 1985, LANCET, V1, P1106
  • [4] BARKER AT, 1986, LANCET, V1, P1325
  • [5] BICKFORD RG, 1965, P 6 INT C MED EL BIO
  • [6] USE OF ANALYSIS OF VARIANCE IN ESTIMATING RELIABILITY OF ISOMETRIC ELBOW FLEXION STRENGTH
    CARLSON, BR
    KROLL, W
    [J]. RESEARCH QUARTERLY, 1970, 41 (02): : 129 - 134
  • [7] Cohen J, 1988, STAT POWER ANAL BEHA, P567
  • [8] dArsonval J-A., 1896, CR HEBD ACAD SCI, V2, P450
  • [9] De Luca C, 1985, MUSCLES ALIVE THEIR, P19
  • [10] Desmedt JE, 1973, NEW DEVELOPMENTS ELE, P277