Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

被引:15
|
作者
Grosser, Oliver S. [1 ]
Kupitz, Dennis [1 ]
Ruf, Juri [1 ]
Czuczwara, Damian [1 ]
Steffen, Ingo G. [1 ]
Furth, Christian [1 ]
Thormann, Markus [1 ]
Loewenthal, David [1 ]
Ricke, Jens [1 ]
Amthauer, Holger [1 ]
机构
[1] Univ Hosp Magdeburg, Dept Radiol & Nucl Med, Magdeburg, Germany
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
FILTERED BACK-PROJECTION; ATTENUATION CORRECTION; REDUCTION; QUALITY; TOMOGRAPHY; MULTISLICE; SYSTEM; PET;
D O I
10.1371/journal.pone.0138658
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R-2 >= 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I <= 60 mA (p <= 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I <= 20 mA, p <= 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Pediatric low-dose head CT: Image quality improvement using iterative model reconstruction
    Rabinowich, Aviad
    Shendler, Genady
    Ben-Sira, Liat
    Shiran, Shelly, I
    NEURORADIOLOGY JOURNAL, 2023, 36 (05): : 555 - 562
  • [22] Evaluation of a low-dose/slow-rotating SPECT-CT system
    Hamann, M.
    Aldridge, M.
    Dickson, J.
    Endozo, R.
    Lozhkin, K.
    Hutton, B. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : 2495 - 2508
  • [23] Accurate tissue characterization in low-dose CT imaging with pure iterative reconstruction
    Murphy, Kevin P.
    McLaughlin, Patrick D.
    Twomey, Maria
    Chan, Vincent E.
    Moloney, Fiachra
    Fung, Adrian J.
    Chan, Faimee E.
    Kao, Tafline
    O'Neill, Siobhan B.
    Watson, Benjamin
    O'Connor, Owen J.
    Maher, Michael M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (02) : 190 - 196
  • [24] The optimal protocols of low-dose CT with iterative reconstruction CT in PET/CT scan
    Yang, Bang-Hung
    Wu, Nien-Yun
    Chen, Guan-Ling
    Wu, Tung-Hsin
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [25] Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study
    Fiachra Moloney
    Karl James
    Maria Twomey
    David Ryan
    Tyler M. Grey
    Amber Downes
    Richard G. Kavanagh
    Niamh Moore
    Mary Jane Murphy
    Jackie Bye
    Brian W. Carey
    Sean E. McSweeney
    Conor Deasy
    Emmett Andrews
    Fergus Shanahan
    Michael M. Maher
    Owen J. O’Connor
    Emergency Radiology, 2019, 26 : 169 - 177
  • [26] Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study
    Moloney, Fiachra
    James, Karl
    Twomey, Maria
    Ryan, David
    Grey, Tyler M.
    Downes, Amber
    Kavanagh, Richard G.
    Moore, Niamh
    Murphy, Mary Jane
    Bye, Jackie
    Carey, Brian W.
    McSweeney, Sean E.
    Deasy, Conor
    Andrews, Emmett
    Shanahan, Fergus
    Maher, Michael M.
    O'Connor, Owen J.
    EMERGENCY RADIOLOGY, 2019, 26 (02) : 169 - 177
  • [27] New Accurate Low-dose and Rapid Hybrid Cardiac Spect/CT Imaging
    Herzog, Bernhard A.
    Husmann, Lars
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Burger, Irene A.
    Gaemperli, Oliver
    Valenta, Ines
    Wyss, Christophe A.
    Kaufmann, Philipp A.
    CIRCULATION, 2009, 120 (18) : S334 - S335
  • [28] Optimization of Low-Dose-CT in SPECT-CT Hybrid Imaging - The Influence of X-ray Tube Current and Hounsfield Unit Bias
    Grosser, O. S.
    Kupitz, D.
    Steffen, I. G.
    Furth, C.
    Czuczwara, D.
    Wissel, H.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S361 - S361
  • [29] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [30] Low-Dose CT in Pelvic Imaging: Comparing Dose and Image Quality in Relation to Clinical Value in a Phantom Study
    Hackenbroch, Carsten
    Feilhuber, Marius
    Halt, Daniel
    Riesner, Hans-Joachim
    Beer, Meinrad
    Wunderlich, Arthur