Compounding for a forward-viewing ring-annular ultrasound array system

被引:4
|
作者
Wang, Y [1 ]
O'Donnell, M [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
3-D imaging; compounding; forward-viewing; IVUS;
D O I
10.1177/016173460102300302
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The 3-D data set from a forward-viewing ring-annular array opens up opportunities for compounding in both axial and lateral directions. To explore this potential, we performed a simulation study analyzing 3-D ultrasound data from various phantoms. For a vessel phantom, our results indicate compounding could boost contrast to noise ratio (CNR) (up to a factor of 4 in our results) without significant compromise in in-plane image resolution. For an isotropic cyst phantom, axial and lateral compounding performs similarly. Such improvement should be helpful for device guidance with IVUS (Intravascular Ultrasound) in interventional procedures.
引用
收藏
页码:147 / 160
页数:14
相关论文
共 50 条
  • [1] A forward-viewing ring-annular array for Intravascular Ultrasound imaging
    Wang, Y
    Stephens, DN
    O'Donnell, M
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1573 - 1576
  • [2] Initial results from a forward-viewing ring-annular ultrasound array for intravascular imaging
    Wang, Y
    Stephens, DN
    O'Donnell, M
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 212 - 215
  • [3] Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging
    Wang, Y
    Stephens, DN
    O'Donnell, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (12) : 1652 - 1664
  • [4] Fabrication of a conformal, ring-annular ultrasound array
    Dann, Aaron E.
    Bennett, David B.
    Singh, Rahul S.
    Lemaire, Jean-Jacques
    Grundfest, Warren S.
    Culjat, Martin O.
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [5] Ring-arrayed Forward-viewing Ultrasound Imaging System: A Feasibility Study
    Tsumura, Ryosuke
    Vang, Doua P.
    Hata, Nobuhiko
    Zhang, Haichong K.
    MEDICAL IMAGING 2020: ULTRASONIC IMAGING AND TOMOGRAPHY, 2020, 11319
  • [6] Concentric-ring arrays for forward-viewing ultrasound imaging
    Tsumura, Ryosuke
    Gao, Shang
    Tang, Yichuan
    Zhang, Haichong K.
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (06)
  • [7] 2D array imaging system for mechanically-steered, forward-viewing ultrasound guidewire
    Olomodosi, Adeoye
    Rojas, Stephan Strassle
    Vu, Phuong
    Lindsey, Brooks D.
    ULTRASONICS, 2024, 142
  • [8] Evaluation of the Feasibility and Efficacy of Forward-Viewing Endoscopic Ultrasound
    Lee, Seohyun
    Seo, Dong Wan
    Choi, Jun-Ho
    Park, Do Hyun
    Lee, Sang Soo
    Lee, Sung Koo
    Kim, Myung-Hwan
    GUT AND LIVER, 2015, 9 (05) : 679 - 684
  • [9] Modified weighting method for forward-looking ring-annular arrays
    Crowe, JR
    Hamilton, JD
    Stephens, DN
    Wang, Y
    O'Donnell, M
    ULTRASONIC IMAGING, 2001, 23 (01) : 19 - 38
  • [10] A forward-viewing intravascular ultrasound catheter suitable for intracoronary use
    Division of Cardiovascular Medicine, Stanford University Hospital, Stanford, CA, United States
    不详
    不详
    Biomedical Instrumentation and Technology, 1997, 31 (01): : 45 - 53