摘要
We describe the application of temperature-controlled ionic liquid based microextraction (TC-IL-ME) of lead(II) ion. The method does not require the use of an organic solvent or a ligand. Rather, the IL is directly added to the aqueous sample containing Pb(II) in a centrifuge tube, and the mixture is heated to 80 A degrees C for 4 min. After cooling at 0 A degrees C, the solution turns cludy due to the formation of fine droplets of the IL containing Pb(II). The IL is separated by centrifugation, acidified, and directly submitted to FAAS by microinjection. The effects of pH value, volume of IL, extraction time, temperature, sample volume and matrix were optimized to result in a preconcentration factor of 30, a detection limit of 5.8 mu g L-1, and a limit of quantification of 19.3 mu g L-1. The method was validated by analyzing a certified reference material (NCSZC81002B; hair). A recovery test performed with spiked samples gave values between 102 % and 105 %. The method was also used to determine Pb(II) in hair samples.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 51 条
[1]   Hollow fiber based-liquid phase microextraction using ionic liquid solvent for preconcentration of lead and nickel from environmental and biological samples prior to determination by electrothermal atomic absorption spectrometry [J].
Abulhassani, Jafar ;
Manzoori, Jamshid L. ;
Amjadi, Mohammad .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 176 (1-3) :481-486
[2]   The removal of cadmium and lead from aqueous solution by ion exchange with Na-Y zeolite [J].
Ahmed, S ;
Chughtai, S ;
Keane, MA .
SEPARATION AND PURIFICATION TECHNOLOGY, 1998, 13 (01) :57-64
[3]   Solid phase extraction of Cd(II), Pb(II), Zn(II) and Ni(II) from food samples using multiwalled carbon nanotubes impregnated with 4-(2-thiazolylazo)resorcinol [J].
ALOthman, Zeid A. ;
Habila, Mohamed ;
Yilmaz, Erkan ;
Soylak, Mustafa .
MICROCHIMICA ACTA, 2012, 177 (3-4) :397-403
[4]  
Amjadi M, 2010, J AOAC INT, V93, P985
[5]   Recent developments in homogeneous and dispersive liquid-liquid extraction for inorganic elements determination. A review [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 80 (02) :413-421
[6]   A novel multi-element coprecipitation technique for separation and enrichment of metal ions in environmental samples [J].
Aydin, Funda Armagan ;
Soylak, Mustafa .
TALANTA, 2007, 73 (01) :134-141
[7]   In situ solvent formation microextraction based on ionic liquids: A novel sample preparation technique for determination of inorganic species in saline solutions [J].
Baghdadi, Majid ;
Shemirani, Farzaneh .
ANALYTICA CHIMICA ACTA, 2009, 634 (02) :186-191
[8]   Temperature-controlled ionic liquid-liquid-phase microextraction for the pre-concentration of lead from environmental samples prior to flame atomic absorption spectrometry [J].
Bai, Huahua ;
Zhou, Qingxiang ;
Xie, Guohong ;
Xiao, Junping .
TALANTA, 2010, 80 (05) :1638-1642
[9]   Monitoring of selenium. in water samples using dispersive liquid-liquid microextraction followed by iridium-modified tube graphite furnace atomic absorption spectrometry [J].
Bidari, Araz ;
Jahromi, Elham Zeini ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani .
MICROCHEMICAL JOURNAL, 2007, 87 (01) :6-12
[10]   Separation and preconcentration by cloud point extraction procedures for determination of ions: recent trends and applications [J].
Bosch Ojeda, Catalina ;
Sanchez Rojas, Fuensanta .
MICROCHIMICA ACTA, 2012, 177 (1-2) :1-21