Vascular Diameter Measurement in CT Angiography: Comparison of Model-Based Iterative Reconstruction and Standard Filtered Back Projection Algorithms In Vitro

被引:35
作者
Suzuki, Shigeru [1 ,2 ]
Machida, Haruhiko [2 ]
Tanaka, Isao [2 ]
Ueno, Eiko [2 ]
机构
[1] Saitama Red Cross Hosp, Dept Radiol, Chuo Ku, Saitama 3380001, Japan
[2] Tokyo Womens Med Univ Med Ctr East, Dept Radiol, Tokyo, Japan
关键词
CT angiography; diameter measurement; experimental studies; iterative reconstruction; CAROTID-ARTERY STENOSIS; DIGITAL-SUBTRACTION-ANGIOGRAPHY; SYMPTOMATIC PATIENTS; CONTRAST-MEDIUM; ENDARTERECTOMY; DISEASE; QUANTIFICATION; DIAGNOSIS; DENSITY;
D O I
10.2214/AJR.12.8689
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the performance of model-based iterative reconstruction (MBIR) in measurement of the inner diameter of models of blood vessels and compare performance between MBIR and a standard filtered back projection (FBP) algorithm. MATERIALS AND METHODS. Vascular models with wall thicknesses of 0.5, 1.0, and 1.5 mm were scanned with a 64-MDCT unit and densities of contrast material yielding 275, 396, and 542 HU. Images were reconstructed images by MBIR and FBP, and the mean diameter of each model vessel was measured by software automation. Twenty separate measurements were repeated for each vessel, and variance among the repeated measures was analyzed for determination of measurement error. For all nine model vessels, CT attenuation profiles were compared along a line passing through the luminal center on axial images reconstructed with FBP and MBIR, and the 10-90% edge rise distances at the boundary between the vascular wall and the lumen were evaluated. RESULTS. For images reconstructed with FBP, measurement errors were smallest for models with 1.5-mm wall thickness, except those filled with 275-HU contrast material, and errors grew as the density of the contrast material decreased. Measurement errors with MBIR were comparable to or less than those with FBP. In CT attenuation profiles of images reconstructed with MBIR, the 10-90% edge rise distances at the boundary between the lumen and vascular wall were relatively short for each vascular model compared with those of the profile curves of FBP images. CONCLUSION. MBIR is better than standard FBP for reducing reconstruction blur and improving the accuracy of diameter measurement at CT angiography.
引用
收藏
页码:652 / 657
页数:6
相关论文
共 21 条
  • [1] [Anonymous], 1995, JAMA-J AM MED ASSOC
  • [2] [Anonymous], N ENGL J MED
  • [3] [Anonymous], 1998, LANCET, V351, P1379
  • [4] Berg M, 2005, AM J NEURORADIOL, V26, P1022
  • [5] DIAGNOSIS OF DISEASE OF THE COMMON CAROTID-ARTERY BIFURCATION - CT ANGIOGRAPHY VS CATHETER ANGIOGRAPHY
    CASTILLO, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (02) : 395 - 398
  • [6] CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT
    Gervaise, Alban
    Osemont, Benoit
    Lecocq, Sophie
    Noel, Alain
    Micard, Emilien
    Felblinger, Jacques
    Blum, Alain
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (02) : 295 - 301
  • [7] Virtual Elastic Sphere Processing Enables Reproducible Quantification of Vessel Stenosis at CT and MR Angiography
    Gremse, Felix
    Grouls, Christoph
    Palmowski, Moritz
    Lammers, Twan
    de Vries, Anke
    Gruell, Holger
    Das, Marco
    Muehlenbruch, Georg
    Akhtar, Shamima
    Schober, Andreas
    Kiessling, Fabian
    [J]. RADIOLOGY, 2011, 260 (03) : 709 - 717
  • [8] New techniques in CT angiography
    Lell, Michael M.
    Anders, Katharina
    Uder, Michael
    Klotz, Ernst
    Ditt, Hendrik
    Vega-Higuera, Fernando
    Boskamp, Tobias
    Bautz, Werner A.
    Tomandl, Bernd F.
    [J]. RADIOGRAPHICS, 2006, 26 : S45 - U58
  • [9] DIAGNOSIS OF CAROTID-ARTERY DISEASE - PRELIMINARY EXPERIENCE WITH MAXIMUM-INTENSITY-PROJECTION SPIRAL CT ANGIOGRAPHY
    MARKS, MP
    NAPEL, S
    JORDAN, JE
    ENZMANN, DR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) : 1267 - 1271
  • [10] Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection
    Moscariello, Antonio
    Takx, Richard A. P.
    Schoepf, U. Joseph
    Renker, Matthias
    Zwerner, Peter L.
    O'Brien, Terrence X.
    Allmendinger, Thomas
    Vogt, Sebastian
    Schmidt, Bernhard
    Savino, Giancarlo
    Fink, Christian
    Bonomo, Lorenzo
    Henzler, Thomas
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (10) : 2130 - 2138