OPTICAL COHERENCE TOMOGRAPHIC IMAGING OF HUMAN TISSUE AT 1.55 μM AND 1.81 μM USING ER- AND TM-DOPED FIBER SOURCES

被引:93
作者
Bouma, Brett E.
Nelson, Lynn E.
Tearney, Guillermo J.
Jones, David J.
Brezinski, Mark E.
Fujimoto, James G. [1 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
interferometry in biomedicine; imaging; optical coherence tomography; fiber optics;
D O I
10.1117/1.429898
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We demonstrate two short-coherence-length, rare-earth-doped fiber optical sources for performing optical coherence tomography (OCT) in human tissue. The first source is a stretched-pulse, mode-locked Er-doped fiber laser with a center wavelength of 1.55 mu m, a power of 100 mW, and a bandwidth of 80 nm. The second is a Tm-doped silica fiber fluorescent source emitting up to 7 mW of power at 1.81 mu m with a bandwidth of 80 nm. The OCT imaging depth of penetration in in vitro human aorta is compared using these sources and conventional 1.3-mu m sources. (C) 1998 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:76 / 79
页数:4
相关论文
共 15 条
[1]  
BOULNOIS J-L, 1986, Lasers in Medical Science, V1, P47, DOI 10.1007/BF02030737
[2]   HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE [J].
BOUMA, B ;
TEARNEY, GJ ;
BOPPART, SA ;
HEE, MR ;
BREZINSKI, ME ;
FUJIMOTO, JG .
OPTICS LETTERS, 1995, 20 (13) :1486-1488
[3]   Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Bilinsky, IP ;
Golubovic, B ;
Fujimoto, JG .
OPTICS LETTERS, 1996, 21 (22) :1839-1841
[4]  
Chernikov S. V., 1997, OSA TECHNICAL DIGEST, VXI
[5]   HIGH-RESOLUTION REFLECTOMETRY IN BIOLOGICAL TISSUES [J].
CLIVAZ, X ;
MARQUISWEIBLE, F ;
SALATHE, RP ;
NOVAK, RP ;
GILGEN, HH .
OPTICS LETTERS, 1992, 17 (01) :4-6
[6]   STRETCHED-PULSE ADDITIVE-PULSE MODE-LOCKING IN FIBER RING LASERS - THEORY AND EXPERIMENT [J].
HAUS, HA ;
TAMURA, K ;
NELSON, LE ;
IPPEN, EP .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1995, 31 (03) :591-598
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   SPATIALLY COHERENT WHITE-LIGHT INTERFEROMETER BASED ON A POINT FLUORESCENT SOURCE [J].
LIU, HH ;
CHENG, PH ;
WANG, JP .
OPTICS LETTERS, 1993, 18 (09) :678-680
[9]   BROADLY TUNABLE SUB-500 FS PULSES FROM AN ADDITIVE-PULSE MODE-LOCKED THULIUM-DOPED FIBER RING LASER [J].
NELSON, LE ;
IPPEN, EP ;
HAUS, HA .
APPLIED PHYSICS LETTERS, 1995, 67 (01) :19-21
[10]   OPTICAL-PROPERTIES OF RAT-LIVER BETWEEN 350 AND 2200 NM [J].
PARSA, P ;
JACQUES, SL ;
NISHIOKA, NS .
APPLIED OPTICS, 1989, 28 (12) :2325-2330