Reduction in operator radiation exposure during transradial catheterization and intervention using a simple lead drape

被引:24
作者
Iqtidar, Ali F. [1 ]
Jeon, Cathy [1 ]
Rothman, Richard [1 ]
Snead, Randall [1 ]
Pyne, Christopher T. [1 ]
机构
[1] Lahey Clin Fdn, Sect Intervent Cardiol, Cardiac Catheterizat Lab, Burlington, MA USA
关键词
PERCUTANEOUS CORONARY INTERVENTION; ANGIOGRAPHY; ACCESS; ARTERY;
D O I
10.1016/j.ahj.2012.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transradial access for cardiac catheterization and intervention is a recognized method for reducing complications and improving patient comfort. However, there are concerns over possible increased operator radiation exposure. We tested the hypothesis that a simple lead drape would reduce operator exposure in transradial procedures. Methods Patients undergoing either diagnostic or interventional procedures using transradial access were assigned in an alternating manner to the use of a 0.5-mm lead apron across the patient's abdomen in addition to standard operator protection. Patients were divided into 4 groups: (left enhanced shielding vs left standard shielding; right enhanced shielding vs right standard shielding). Dosimeters were taped to the primary and secondary operators' left wrist and outside the thyroid guard. The operator exposure was measured for each site on every case in centigray. Results In standard shielded patients, there was no increase in operator exposure between the left and right approach patients at any measurement site. Measured exposure was reduced with enhanced shielding at all dosimeter sites except the secondary operator's collar (both left and right) and the primary operator's collar from the right. There was no significant difference in fluoroscopy, air kerma, or dose area product between standard and enhanced shielded patients. Conclusions The use of a lead drape reduces the rate of operator radiation exposure at multiple measurement sites. Use of the left radial approach was not associated with an increase in operator exposure compared with the right radial approach. (Am Heart J 2013;165:293-8.)
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [41] Rescue of Severely Twice-Kinked Catheter During Transradial Coronary Intervention Using Balloon Technique
    Rahimov, Uzeyir
    Karimli, Emin
    Musayeva, Gunel
    Salimov, Ziya
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 40 : S243 - S245
  • [42] Fluoroscopy Pulse Rate Reduction during Diagnostic and Therapeutic Imaging in the Cardiac Catheterization Laboratory: An Evaluation of Radiation Dose, Procedure Complications and Outcomes
    Hansen, James W.
    Foy, Andrew
    Schmidt, Torrey
    Ghahramani, Mehrdad
    Chambers, Charles E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (04) : 665 - 670
  • [43] Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX)
    Sciahbasi, Alessandro
    Calabro, Paolo
    Sarandrea, Alessandro
    Rigattieri, Stefano
    Tomassini, Francesco
    Sardella, Gennaro
    Zavalloni, Dennis
    Cortese, Bernardo
    Limbruno, Ugo
    Tebaldi, Matteo
    Gagnor, Andrea
    Rubartelli, Paolo
    Zingarelli, Antonio
    Valgimigli, Marco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2014, 15 (04) : 209 - 213
  • [44] Estimating radiation exposure during paediatric cardiac catheterisation: a potential for radiation reduction with air gap technique
    Chamberlain, Reid C.
    Shindhelm, Alexis C.
    Wang, Chu
    Fleming, Gregory A.
    Hill, Kevin D.
    CARDIOLOGY IN THE YOUNG, 2019, 29 (12) : 1474 - 1480
  • [45] Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention
    Jin, Zhigeng
    Yang, Shengli
    Jing, Limin
    Liu, Huiliang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06) : 1207 - 1213
  • [46] Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention
    Zhigeng Jin
    Shengli Yang
    Limin Jing
    Huiliang Liu
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1207 - 1213
  • [47] Reducing Needle-To-Balloon Time by Using a Single Guiding Catheter during Transradial Primary Coronary Intervention
    Moon, Keon-Woong
    Kim, Ji-Hoon
    Kim, Ju-Youn
    Jung, Mi-Hyang
    Kim, Gee-Hee
    Yoo, Ki-Dong
    Kim, Chul-Min
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (04) : 330 - 336
  • [48] Radiation reduction during percutaneous coronary intervention A new protocol with a low frame rate and selective fluoroscopic image storage
    Chon, Min Ku
    Chun, Kook Jin
    Lee, Dae Sung
    Lee, Soo Yong
    Hwang, Jongmin
    Lee, Sang Hyun
    Hwang, Ki Won
    Kim, Jeong Su
    Park, Young Huyn
    Kim, June Hong
    MEDICINE, 2017, 96 (30)
  • [49] Time-Course Reduction in Patient Exposure to Radiation From Coronary Interventional Procedures The Greater Paris Area Percutaneous Coronary Intervention Registry
    Georges, Jean-Louis
    Karam, Nicole
    Tafflet, Muriel
    Livarek, Bernard
    Bataille, Sophie
    Loyeau, Aurelie
    Mapouata, Mireille
    Benamer, Hakim
    Caussin, Christophe
    Garot, Philippe
    Varenne, Olivier
    Barbou, Franck
    Teiger, Emmanuel
    Funck, Francois
    Karrillon, Gaetan
    Lambert, Yves
    Spaulding, Christian
    Jouven, Xavier
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (08)
  • [50] Reduction in Radiation Dose in a Pediatric Cardiac Catheterization Lab Using the Philips AlluraClarity X-ray System
    Sullivan, Patrick M.
    Harrison, David
    Badran, Sarah
    Takao, Cheryl M.
    Ing, Frank F.
    PEDIATRIC CARDIOLOGY, 2017, 38 (08) : 1583 - 1591