摘要
Background Transradial access for cardiac catheterization and intervention is a recognized method for reducing complications and improving patient comfort. However, there are concerns over possible increased operator radiation exposure. We tested the hypothesis that a simple lead drape would reduce operator exposure in transradial procedures. Methods Patients undergoing either diagnostic or interventional procedures using transradial access were assigned in an alternating manner to the use of a 0.5-mm lead apron across the patient's abdomen in addition to standard operator protection. Patients were divided into 4 groups: (left enhanced shielding vs left standard shielding; right enhanced shielding vs right standard shielding). Dosimeters were taped to the primary and secondary operators' left wrist and outside the thyroid guard. The operator exposure was measured for each site on every case in centigray. Results In standard shielded patients, there was no increase in operator exposure between the left and right approach patients at any measurement site. Measured exposure was reduced with enhanced shielding at all dosimeter sites except the secondary operator's collar (both left and right) and the primary operator's collar from the right. There was no significant difference in fluoroscopy, air kerma, or dose area product between standard and enhanced shielded patients. Conclusions The use of a lead drape reduces the rate of operator radiation exposure at multiple measurement sites. Use of the left radial approach was not associated with an increase in operator exposure compared with the right radial approach. (Am Heart J 2013;165:293-8.)
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [1] Reduction in Radiation Exposure Rate During Transradial Catheterization and Intervention Using a Simple Lead Drape
    Iqtidar, Ali F.
    Snead, Randall
    Rothman, Richard
    Jeon, Cathy
    Dwyer, Kevin
    Pyne, Christopher
    CIRCULATION, 2011, 124 (21)
  • [2] Reduction in Primary Operator Radiation Dose Exposure During Coronary Angioplasty Using Radiation Absorbing Drape
    Sharma, Amit B.
    Agrawal, Richa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [3] Operator Experience and Radiation Exposure During Transradial and Transfemoral Procedures Reply
    Mercuri, Mathew
    Mehta, Shamir
    Natarajan, Madhu K.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (08) : 937 - 938
  • [4] Determinants of operator and patient radiation exposure during cardiac catheterization: Insights from the RadiCure (RADIation reduction during cardiac catheterization using real-timE monitoring) trial
    Christopoulos, Georgios
    Papayannis, Aristotelis C.
    Alomar, Mohammed
    Christakopoulos, Georgios E.
    Kotsia, Anna
    Michael, Tesfaldet T.
    Rangan, Bavana V.
    Roesle, Michele
    Shorrock, Deborah
    Makke, Lorenza
    Maragkoudakis, Spyros
    Mohammad, Atif
    Sarode, Karan
    Chambers, Charles E.
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (07) : 1046 - 1055
  • [5] Efficacy of the SEPARPROCATH® radiation drape to reduce radiation exposure during cardiac catheterization: A pilot comparative study
    Patet, Camille
    Ryckx, Nick
    Arroyo, Diego
    Cook, Stephane
    Goy, Jean-Jacques
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 94 (03) : 387 - 391
  • [6] A novel lead attenuator to reduce operator exposure to scattered radiation in transradial coronary procedures
    Osherov, Azriel B.
    Seidelin, Peter
    Wolff, Rafael
    Wright, Graham A.
    Strauss, Bradley H.
    Robert, Normand
    EUROINTERVENTION, 2013, 9 (06) : 757 - 760
  • [7] Factors affecting radiation exposure during transradial cardiac catheterisation and percutaneous coronary intervention
    Mantis, C.
    Papadakis, E.
    Anadiotis, A.
    Kafkas, N.
    Patsilinakos, S.
    CLINICAL RADIOLOGY, 2022, 77 (05) : E387 - E393
  • [8] Operators' radiation exposure reduction during cardiac catheterization using a removable shield
    Arrivi, Alessio
    Pucci, G.
    Vaudo, G.
    Bier, N.
    Bock, C.
    Casavecchia, M.
    Bazzucchi, M.
    Dominici, M.
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (04) : 379 - 384
  • [9] A preliminary study on the radiation dose reduction during catheterization procedures using simple partial patient shielding
    Serati, Alireza
    Hashemi, Ashkan
    Sharifkashani, Babak
    Nourbakhsh, Sourmah
    Hashemi, Arash
    Emami, Sepideh
    Movahed, Mohammad Reza
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2021, 22 (03) : 891 - 894
  • [10] The Impact Of Operator Experience During Institutional Adoption Of Transradial Cardiac Catheterization
    Huded, Chetan
    Youmans, Quentin
    Sweis, Ranya
    Ricciardi, Mark
    Flaherty, James
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B173 - B174