Reduction in operator radiation exposure during transradial catheterization and intervention using a simple lead drape

被引:24
作者
Iqtidar, Ali F. [1 ]
Jeon, Cathy [1 ]
Rothman, Richard [1 ]
Snead, Randall [1 ]
Pyne, Christopher T. [1 ]
机构
[1] Lahey Clin Fdn, Sect Intervent Cardiol, Cardiac Catheterizat Lab, Burlington, MA USA
关键词
PERCUTANEOUS CORONARY INTERVENTION; ANGIOGRAPHY; ACCESS; ARTERY;
D O I
10.1016/j.ahj.2012.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transradial access for cardiac catheterization and intervention is a recognized method for reducing complications and improving patient comfort. However, there are concerns over possible increased operator radiation exposure. We tested the hypothesis that a simple lead drape would reduce operator exposure in transradial procedures. Methods Patients undergoing either diagnostic or interventional procedures using transradial access were assigned in an alternating manner to the use of a 0.5-mm lead apron across the patient's abdomen in addition to standard operator protection. Patients were divided into 4 groups: (left enhanced shielding vs left standard shielding; right enhanced shielding vs right standard shielding). Dosimeters were taped to the primary and secondary operators' left wrist and outside the thyroid guard. The operator exposure was measured for each site on every case in centigray. Results In standard shielded patients, there was no increase in operator exposure between the left and right approach patients at any measurement site. Measured exposure was reduced with enhanced shielding at all dosimeter sites except the secondary operator's collar (both left and right) and the primary operator's collar from the right. There was no significant difference in fluoroscopy, air kerma, or dose area product between standard and enhanced shielded patients. Conclusions The use of a lead drape reduces the rate of operator radiation exposure at multiple measurement sites. Use of the left radial approach was not associated with an increase in operator exposure compared with the right radial approach. (Am Heart J 2013;165:293-8.)
引用
收藏
页码:293 / 298
页数:6
相关论文
共 20 条
[1]   Decreasing Operators' Radiation Exposure During Coronary Procedures: The Transradial Radiation Protection Board [J].
Behan, Miles ;
Haworth, Peter ;
Colley, Paul ;
Brittain, Michael ;
Hince, Andrew ;
Clarke, Michael ;
Ghuran, Azad ;
Saha, Mrinal ;
Hildick-Smith, David .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (01) :79-84
[2]   Comparison of operator radiation exposure with optimized radiation protection devices during coronary angiograms and ad hoc percutaneous coronary interventions by radial and femoral routes [J].
Brasselet, Camille ;
Blanpain, Thierry ;
Tassan-Mangina, Sophie ;
Deschildre, Alain ;
Duval, Sebastien ;
Vitry, Fabien ;
Gaillot-Petit, Nathalie ;
Clement, Jean Paul ;
Metz, Damien .
EUROPEAN HEART JOURNAL, 2008, 29 (01) :63-70
[3]   Association of the arterial access site at angioplasty with transfusion and mortality: the MORTAL study (Mortality benefit Of Reduced Transfusion after percutaneous coronary intervention via the Arm or Leg) [J].
Chase, A. J. ;
Fretz, E. B. ;
Warburton, W. P. ;
Klinke, W. P. ;
Carere, R. G. ;
Pi, D. ;
Berry, B. ;
Hilton, J. D. .
HEART, 2008, 94 (08) :1019-1025
[4]   Effective Use of Radiation Shields to Minimize Operator Dose During Invasive Cardiology Procedures [J].
Fetterly, Kenneth A. ;
Magnuson, Dixon J. ;
Tannahill, Gordon M. ;
Hindal, Mark D. ;
Mathew, Verghese .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (10) :1133-1139
[5]   Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access [J].
Geijer, H ;
Persliden, J .
EUROPEAN RADIOLOGY, 2004, 14 (09) :1674-1680
[6]   Reduction of radiation delivered to patients undergoing invasive coronary procedures. Effect of a programme for dose reduction based on radiation-protection training [J].
Georges, Jean-Louis ;
Livarek, Bernard ;
Gibault-Genty, Geraldine ;
Aziza, Jean-Paul ;
Hautecoeur, Jean-Louis ;
Soleille, Henry ;
Messaoudi, Hela ;
Annabi, Nizar ;
Kebsi, Mohammed Al .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (12) :821-827
[7]  
Goldberg SL, 1998, CATHETER CARDIO DIAG, V44, P147, DOI 10.1002/(SICI)1097-0304(199806)44:2<147::AID-CCD5>3.3.CO
[8]  
2-1
[9]   Radial versus femoral access for coronary angiography or intervention and the impact on major bleeding and ischemic events: A systematic review and meta-analysis of randomized trials [J].
Jolly, Sanjit S. ;
Amlani, Shoaib ;
Hamon, Martial ;
Yusuf, Salim ;
Mehta, Shamir R. .
AMERICAN HEART JOURNAL, 2009, 157 (01) :132-140
[10]  
Jolly SS, 2011, AM HEART J, V161, p[254, e1]