Spectrum correction algorithm for detectors in airborne radioactivity monitoring equipment NH-UAV based on a ratio processing method

被引:9
作者
Cao, Ye [1 ]
Tang, Xiao-Bin [1 ,2 ]
Wang, Peng [1 ]
Meng, Jia [1 ]
Huang, Xi [1 ]
Wen, Liang-Sheng [1 ]
Chen, Da [1 ,2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Engn, Nanjing 210016, Jiangsu, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Jiangsu Key Lab Nucl Energy Equipment Mat Engn, Nanjing 210016, Jiangsu, Peoples R China
关键词
Nuclear accident; Detector; Monte Carlo; Gamma-spectrum correction; NUCLEAR-POWER-PLANT; MONTE-CARLO-SIMULATION; EFFICIENCY CALCULATIONS; UNMANNED HELICOPTER; RADIATION; CALIBRATION; NAI(TL);
D O I
10.1016/j.nima.2015.07.012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The unmanned aerial vehicle (UAV) radiation monitoring method plays an important role in nuclear accidents emergency. In this research, a spectrum correction algorithm about the UAV airborne radioactivity monitoring equipment NH-UAV was studied to measure the radioactive nuclides within a small area in real time and in a fixed place. The simulation spectra of the high-purity germanium (HPGe) detector and the lanthanum bromide (LaBr3) detector in the equipment were obtained using the Monte Carlo technique. Spectrum correction coefficients were calculated after performing ratio processing techniques about the net peak areas between the double detectors on the detection spectrum of the LaBr3 detector according to the accuracy of the detection spectrum of the HPGe detector. The relationship between the spectrum correction coefficient and the size of the source term was also investigated. A good linear relation exists between the spectrum correction coefficient and the corresponding energy (R-2=0.9765). The maximum relative deviation from the real condition reduced from 1.65 to 0.035. The spectrum correction method was verified as feasible. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:290 / 296
页数:7
相关论文
共 20 条
  • [1] Reliability of two calculation codes for efficiency calibrations of HPGe detectors
    Abbas, K
    Simonelli, F
    D'Alberti, F
    Forte, M
    Stroosnijder, MF
    [J]. APPLIED RADIATION AND ISOTOPES, 2002, 56 (05) : 703 - 709
  • [2] MOBILE SURVEY OF ENVIRONMENTAL GAMMA-RADIATION AND FALLOUT LEVELS IN FINLAND AFTER THE CHERNOBYL ACCIDENT
    ARVELA, H
    MARKKANEN, M
    LEMMELA, H
    [J]. RADIATION PROTECTION DOSIMETRY, 1990, 32 (03) : 177 - 183
  • [3] A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations
    Boson, Jonas
    Agren, Goeran
    Johansson, Lennart
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 587 (2-3) : 304 - 314
  • [4] Energy and resolution calibration of NaI(Tl) and LaBr3(Ce) scintillators and validation of an EGS5 Monte Carlo user code for efficiency calculations
    Casanovas, R.
    Morant, J. J.
    Salvado, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 675 : 78 - 83
  • [5] Estimates of radioxenon released from Southern Hemisphere medical isotope production facilities using measured air concentrations and atmospheric transport modeling
    Eslinger, Paul W.
    Friese, Judah I.
    Lowrey, Justin D.
    McIntyre, Justin I.
    Miley, Harry S.
    Schrom, Brian T.
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2014, 135 : 94 - 99
  • [6] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    Gong ChunHui
    Zeng GuoQiang
    Ge LiangQuan
    Tang Xiaobin
    Tan ChengJun
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (09) : 1840 - 1845
  • [7] Korsbech U., 1993, DANMARKS TEKNISKE HO
  • [8] Efficiency calibration and simulation of a LaBr3(Ce) detector in close-geometry
    Kumar, G. Anil
    Mazumdar, I.
    Gothe, D. A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3) : 183 - 186
  • [9] Design of a radiation surveillance unit for an unmanned aerial vehicle
    Kurvinen, K
    Smolander, P
    Pöllänen, R
    Kuutkankorpi, S
    Kettunen, M
    Lyytinen, J
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2005, 81 (01) : 1 - 10
  • [10] LOSKA L, 1988, APPL RADIAT ISOTOPES, V39, P475, DOI 10.1016/0883-2889(88)90192-X