Reusable surface plasmon resonance biosensor chip for the detection of H1N1 influenza virus

被引:67
作者
Yoo, Haneul [1 ]
Shin, Junghyun [1 ]
Sim, Jieun [3 ,4 ,5 ]
Cho, Hyunmin [3 ,5 ]
Hong, Seunghun [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Phys & Astron, Seoul 08826, South Korea
[2] Seoul Natl Univ, Inst Appl Phys, Seoul 08826, South Korea
[3] Univ Sci & Technol, KRIBB Sch Biotechnol, Dept Nanobiotechnol, Daejeon 34113, South Korea
[4] Korea Res Inst Biosci & Biotechnol KRIBB, Bionano Res Ctr, Daejeon 34141, South Korea
[5] BioNano Hlth Guard Res Ctr H GUARD, Daejeon 34141, South Korea
基金
新加坡国家研究基金会; 欧洲研究理事会;
关键词
Surface plasmon resonance; Biosensor; Reusable; Ferromagnetic pattern; Magnetic trapping-releasing; Influenza; PROTEIN-PROTEIN; SPR BIOSENSOR; REGENERATION; SIMULATION;
D O I
10.1016/j.bios.2020.112561
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We developed a reusable magnetic surface plasmon resonance (SPR) sensor chip for detecting various target molecules repeatedly in a conventional SPR system. Here, ferromagnetic patterns on a SPR sensor chip were utilized to trap a layer of magnetic particles, and they were utilized as a solid substrate for SPR sensing in a conventional SPR system. After a sensing experiment, the used magnetic particles were removed by external magnetic fields, and a new layer of magnetic particles was immobilized to the SPR sensor chip for additional sensing measurements. Since magnetic particles were trapped on the ferromagnetic patterns, we could use our reusable SPR chip for SPR sensing measurements in a traditional SPR system without any applied magnetic fields. Significantly, ferromagnetic patterns on the sensor chip surface deflected the strong external fields, so that the large aggregation of magnetic particles on the sensor surface was reduced. We demonstrated using a single reusable SPR sensor chip to measure the nucleoprotein (NP) of H1N1 influenza virus solution ranging repeatedly for more than 7 times without significant signal degradation. Also, different target molecules could be repeatedly measured in a single SPR chip. Since our reusable SPR sensor chip can be repeatedly used in a conventional SPR system without any chemical processes for refreshment, the cost for SPR sensing should be significantly reduced. In this case, our reusable SPR sensor chip can be a major breakthrough and can be used for versatile practical applications of SPR sensors.
引用
收藏
页数:7
相关论文
共 39 条
[1]   Simulation and experimental investigation of optical transparency in gold island films [J].
Axelevitch, Alexander ;
Apter, Boris ;
Golan, Gady .
OPTICS EXPRESS, 2013, 21 (04) :4126-4138
[2]   Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads [J].
Centi, Sonia ;
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1466-1473
[3]   Femtomolar Detection by Nanocoated Fiber Label-Free Biosensors [J].
Chiavaioli, Francesco ;
Zubiate, Pablo ;
Del Villar, Ignacio ;
Zamarreno, Carlos R. ;
Giannetti, Ambra ;
Tombelli, Sara ;
Trono, Cosimo ;
Arregui, Francisco J. ;
Matias, Ignacio R. ;
Baldini, Francesco .
ACS SENSORS, 2018, 3 (05) :936-943
[4]   Reusable biosensors via in situ electrochemical surface regeneration in microfluidic applications [J].
Choi, Seokheun ;
Chae, Junseok .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (02) :527-531
[5]   Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV) [J].
Chung, JW ;
Kim, SD ;
Bernhardt, R ;
Pyun, JC .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 :416-422
[6]   Influence of the metal film thickness on the sensitivity of surface plasmon resonance biosensors [J].
Ekgasit, S ;
Thammacharoen, C ;
Yu, F ;
Knoll, W .
APPLIED SPECTROSCOPY, 2005, 59 (05) :661-667
[7]  
Fischer MJE, 2010, METHODS MOL BIOL, V627, P55, DOI 10.1007/978-1-60761-670-2_3
[8]   Biosensor Regeneration: A Review of Common Techniques and Outcomes [J].
Goode, J. A. ;
Rushworth, J. V. H. ;
Millner, P. A. .
LANGMUIR, 2015, 31 (23) :6267-6276
[9]   Fiber Grating-Assisted Surface Plasmon Resonance for Biochemical and Electrochemical Sensing [J].
Guo, Tuan .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2017, 35 (16) :3323-3333
[10]   Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milk [J].
Homola, J ;
Dostálek, J ;
Chen, SF ;
Rasooly, A ;
Jiang, SY ;
Yee, SS .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2002, 75 (1-2) :61-69