Comparison by X-ray diffraction and infrared spectroscopy of two samples of α quartz with the NIST SRM 1878a α quartz

被引:10
作者
Kauffer, E [1 ]
Moulut, JC [1 ]
Masson, A [1 ]
Protois, JC [1 ]
Grzebyk, M [1 ]
机构
[1] INRS, Dept Metrol Polluants, Lab Anal Phys, F-54501 Vandoeuvre Les Nancy, France
关键词
crystallinity; infrared spectrophotometry; particle size; quartz; X-ray diffraction;
D O I
10.1093/annhyg/mef050
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The aim of this study was to compare the X-ray diffraction and infrared spectrophotometric patterns of two samples of alpha quartz (QUIN1 and QUIN2) with that of NIST SRM 1878a alpha quartz certified 100% crystalline. As it is known that the intensity diffracted and the absorbance per mass unit for a given type of alpha quartz depend on its particle size, this factor was taken into account. To do this, different types of alpha quartz were sampled on filters using a Dorr-Oliver cyclone to select particle size. Variation in the flow rate of the cyclone in the range 1.2-2.8 l/min allowed the volume median diameter of the sampled particles to be varied. For the four strongest diffraction lines it was observed that the intensity per mass unit increased with the volume median diameter of the particles. For infrared spectrophotometry for analytical band wavelengths close to 12.5 mum, it was observed that the absorbance per mass unit decreased as particle size increased. The opposite effect was noted for analytical band wavelengths >14.4 mum. Compared with SRM 1878a alpha quartz, certified 100% crystalline, the purity of QUIN1 alpha quartz was 93.1% (confidence interval 92.4-93.8%) when measured by X-ray diffraction and 91.5% (confidence interval 90.1-92.9%) when measured by infrared spectrophotometry. In the case of QUIN2 alpha quartz the purity was globally lower.
引用
收藏
页码:409 / 421
页数:13
相关论文
共 29 条
[1]  
ALTREE-WILLIAMS S, 1977, Annals of Occupational Hygiene, V20, P109, DOI 10.1093/annhyg/20.2.109
[2]   AMORPHOUS SURFACE AND QUANTITATIVE X-RAY-POWDER DIFFRACTOMETRY [J].
ALTREEWILLIAMS, S ;
BYRNES, JG ;
JORDAN, B .
ANALYST, 1981, 106 (1258) :69-75
[3]  
[Anonymous], IARC MON EV CARC RIS
[4]  
BHASKAR R, 1994, AM IND HYG ASSOC J, V55, P605, DOI 10.1080/15428119491018682
[5]  
BIGGINS PDE, 1982, BCIRA J, V30, P235
[6]  
BRINDLEY GW, 1959, J AM CERAM SOC, V42, P643
[7]  
DEWELL P, 1980, BCIRA J, V28, P411
[8]   PARTICLE-SIZE EFFECTS IN DETERMINATION OF RESPIRABLE ALPHA-QUARTZ BY X-RAY-DIFFRACTION [J].
EDMONDS, JW ;
HENSLEE, WW ;
GUERRA, RE .
ANALYTICAL CHEMISTRY, 1977, 49 (14) :2196-2203
[9]  
Eller PM, 1999, AM IND HYG ASSOC J, V60, P533, DOI 10.1202/0002-8894(1999)060<0533:PATSV>2.0.CO
[10]  
2