被引:71
作者
Zhang, Fan [1 ]
Zou, Mingqiang [1 ]
Chen, Yan [1 ]
Li, Jinfeng [1 ]
Wang, Yanfei [1 ]
Qi, Xiaohua [1 ]
Xue, Qiang [1 ]
机构
[1] Chinese Acad Inspect & Quarantine, Beijing 100123, Peoples R China
关键词
Fluorescence strip; Strip reader; Rapid detection; Pantoea stewartii subsp stewartii; SILICA NANOPARTICLES; IMMUNOSORBENT-ASSAY; ERWINIA-STEWARTII; DIFFERENTIATION; IDENTIFICATION; STRAINS; SEED;
D O I
10.1016/j.bios.2013.06.065
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lateral flow immunoassay is used in commercial pregnancy detection, and is an accepted point-of-care testing technique. The most widely used format for lateral flow immunochromatographic strips uses gold nanoparticles for calorimetric detection. However, this method often suffers from poor quantitative discrimination and low analytical sensitivity. To address these limitations, lanthanide chelate-loaded silica nanoparticles have been used as fluorescent labels. The fluorescent nanoparticles can easily bind to antibodies, with dextran as a linker. The strip reader described here was based on a sandwich immunoreaction performed on a strip, using lanthanide-labeled antibodies that served as signal vehicles for the fluorescent readout. The strip reader was used as a quantitative test system. In this work, Pantoea stewartii subsp. stewartii (Pss) was used as a model analyte to demonstrate the use of the strip reader. Under optimal conditions, the detection limit was determined as 10(3) cfu/mL. The quantification limit was calculated to be 104 cfu/mL. The detection limit for Pss was 100 times lower than those displayed by colloidal gold-labeled strips or ELISAs. No cross-reactions were observed with the other nine strains, indicating the good specificity of the Pss strip. This strip showed good stability in repeated tests. The tests using the fluorescence immunochromatographic strip were easy to perform, rapid, and sensitive. Methods using fluorescence strips and a strip reader have the potential to be a powerful tool for the quantification of bacteria. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 24 条
[1]   Optimization of dye-doped silica nanoparticles prepared using a reverse microemulsion method [J].
Bagwe, RP ;
Yang, CY ;
Hilliard, LR ;
Tan, WH .
LANGMUIR, 2004, 20 (19) :8336-8342
[2]   An enzyme immunoanalytical system based on sequential cross-flow chromatography [J].
Cho, JH ;
Paek, EH ;
Cho, IH ;
Paek, SH .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4091-4097
[3]  
Claflin LE, 1999, Compendium of Corn Diseases, P3
[4]   CHARACTERISTICS OF MICROPLATE METHOD OF ENZYME-LINKED IMMUNOSORBENT ASSAY FOR DETECTION OF PLANT-VIRUSES [J].
CLARK, MF ;
ADAMS, AN .
JOURNAL OF GENERAL VIROLOGY, 1977, 34 (MAR) :475-483
[5]   Identification of Pantoea stewartii subsp stewartii by PCR and strain differentiation by PFGE [J].
Coplin, DL ;
Majerczak, DR ;
Zhang, YX ;
Kim, WS ;
Jock, S ;
Geider, K .
PLANT DISEASE, 2002, 86 (03) :304-311
[6]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[7]  
EPPO Standards PM 7/60, 2006, B OEPP EPPO B, V36, P111
[8]   Levels of Stewart's wilt resistance necessary to prevent reductions in yield of sweet corn hybrids [J].
Freeman, ND ;
Pataky, JK .
PLANT DISEASE, 2001, 85 (12) :1278-1284
[9]   Two-Dimensional Paper Network Format That Enables Simple Multistep Assays for Use in Low-Resource Settings in the Context of Malaria Antigen Detection [J].
Fu, Elain ;
Liang, Tinny ;
Spicar-Mihalic, Paolo ;
Houghtaling, Jared ;
Ramachandran, Sujatha ;
Yager, Paul .
ANALYTICAL CHEMISTRY, 2012, 84 (10) :4574-4579
[10]   PREPARATION AND CHARACTERIZATION OF AU COLLOID MONOLAYERS [J].
GRABAR, KC ;
FREEMAN, RG ;
HOMMER, MB ;
NATAN, MJ .
ANALYTICAL CHEMISTRY, 1995, 67 (04) :735-743