Impact of a Paper-Based Dynamic Insulin Infusion Protocol on Glycemic Variability, Time in Target, and Hypoglycemic Risk: A Stepped Wedge Trial in Medical Intensive Care Unit Patients

被引:14
作者
Clergeau, Antoine [1 ]
Parienti, Jean-Jacques [2 ]
Reznik, Yves [1 ]
Clergeau, Deborah [3 ]
Seguin, Amelie [3 ]
Valette, Xavier [3 ]
du Cheyron, Damien [3 ]
Joubert, Michael [1 ]
机构
[1] Univ Hosp Caen, Diabet Care Unit, F-14033 Caen, France
[2] Univ Hosp Caen, Biostat Unit, Caen, France
[3] Univ Hosp Caen, Intens Care Unit, Caen, France
关键词
Stress hyperglycemia; Glycemic variability; Hypoglycemia; Intensive care unit; Dynamic insulin infusion protocol; Nurse care; CRITICALLY-ILL PATIENTS; POINT-OF-CARE; BLOOD-GLUCOSE; ENDOTHELIAL FUNCTION; MULTICENTER COHORT; OXIDATIVE STRESS; HYPERGLYCEMIA; MORTALITY; MANAGEMENT; THERAPY;
D O I
10.1089/dia.2016.0314
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stress-induced hyperglycemia is a common feature of intensive care unit (ICU) patients. Besides mean blood glucose (BG) level, glucose variability and hypoglycemia have been highlighted as independent predictors of ICU and hospital mortality. Recent ICU recommendations suggest using insulin infusion protocols that can minimize glucose variability and hypoglycemic risk. Our aim was to assess the efficacy, safety, and acceptance by nurses of a paper-based simple dynamic insulin protocol compared with those by nurses of a paper-based static protocol. Methods: This is a 1 year stepped-wedge study that compared a static sliding scale protocol (SP - static protocol) with a validated dynamic paper-based intravenous insulin infusion protocol (DP - dynamic protocol) in medical ICU patients of a single university hospital. Patients with stress-induced hyperglycemia >9.9 mmol/L and >= 48 h intravenous insulin infusion were included in this trial. Results: One hundred thirty-one patients were included and received continuous intravenous insulin infusion managed with SP (n = 65) or DP (n = 66). Glucose variability was significantly higher in the SP group than in the DP group (mean average glucose excursion index: 0.90 [0.00-1.91] mmol/L vs. 0.00 [0.00-0.90] mmol/L, respectively; P = 0.001). The percentage of time spent in the target range (7.7-9.9 mmol/L) was lower in the SP group than in the DP group (42.5% [28.8%-54.2%] vs. 47.5% [36.6%-57.1%]; P = 0.037). Low BG (<4.4 mmol/L) and hypoglycemia (<3.3 mmol/L) were more frequent in the SP group than in the DP group. According to a satisfaction survey, this protocol was well accepted by nurses. Conclusions: Our simple and feasible paper-based, dynamic insulin infusion protocol reduced glycemic variability and hypoglycemic risk in a medical ICU.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 38 条
[1]   Space GlucoseControl system for blood glucose control in intensive care patients - a European multicentre observational study [J].
Blaha, Jan ;
Barteczko-Grajek, Barbara ;
Berezowicz, Pawel ;
Charvat, Jiri ;
Chvojka, Jiri ;
Grau, Teodoro ;
Holmgren, Jonathan ;
Jaschinski, Ulrich ;
Kopecky, Petr ;
Manak, Jan ;
Moehl, Mette ;
Paddle, Jonathan ;
Pasculli, Marcello ;
Petersson, Johan ;
Petros, Sirak ;
Radrizzani, Danilo ;
Singh, Vinodkumar ;
Starkopf, Joel .
BMC ANESTHESIOLOGY, 2016, 16
[2]   Comparison of Three Protocols for Tight Glycemic Control in Cardiac Surgery Patients [J].
Blaha, Jan ;
Kopecky, Petr ;
Matias, Michal ;
Hovorka, Roman ;
Kunstyr, Jan ;
Kotulak, Tomas ;
Lips, Michal ;
Rubes, David ;
Stritesky, Martin ;
Lindner, Jaroslav ;
Semrad, Michal ;
Haluzik, Martin .
DIABETES CARE, 2009, 32 (05) :757-761
[3]   A randomized controlled trial comparing a computer-assisted insulin infusion protocol with a strict and a conventional protocol for glucose control in critically ill patients [J].
Cavalcanti, Alexandre B. ;
Silva, Eliezer ;
Pereira, Adriano J. ;
Caldeira-Filo, Milton ;
Almeida, Francisca P. ;
Westphal, Glauco A. ;
Beims, Renate ;
Fernandes, Caio C. ;
Correa, Thiago D. ;
Gouvea, Marcos R. ;
Eluf-Neto, Jose .
JOURNAL OF CRITICAL CARE, 2009, 24 (03) :371-378
[4]   'Glycaemic variability': a new therapeutic challenge in diabetes and the critical care setting [J].
Ceriello, A. ;
Ihnat, M. A. .
DIABETIC MEDICINE, 2010, 27 (08) :862-867
[5]   Oscillating glucose is more deleterious to endothelial function and oxidative stress than mean glucose in normal and type 2 diabetic patients [J].
Ceriello, Antonio ;
Esposito, Katherine ;
Piconi, Ludovica ;
Ihnat, Michael A. ;
Thorpe, Jessica E. ;
Testa, Roberto ;
Boemi, Massimo ;
Giugliano, Dario .
DIABETES, 2008, 57 (05) :1349-1354
[6]   Approved IFCC recommendation on reporting results for blood glucose [J].
D'Orazio, Paul ;
Burnett, Robert W. ;
Fogh-Andersen, Niels ;
Jacobs, Ellis ;
Kuwa, Katsuhiko ;
Kuelpmann, Wolf R. ;
Larsson, Lasse ;
Lewenstam, Andrzej ;
Maas, Anton H. J. ;
Mager, Gerhard ;
Naskalski, Jerzy W. ;
Okorodudu, Anthony O. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (12) :1486-1490
[7]   Evaluation of nursing adherence to a paper-based graduated continuous intravenous regular human insulin infusion algorithm [J].
Dickerson, Roland N. ;
Johnson, Jessica L. ;
Maish, George O. ;
Minard, Gayle, III ;
Brown, Rex O. .
NUTRITION, 2012, 28 (10) :1008-1011
[8]   Glucose measurement: Confounding issues in setting targets for inpatients management [J].
Dungan, Kathleen ;
Chapman, John ;
Braithwaite, Susan S. ;
Buse, John .
DIABETES CARE, 2007, 30 (02) :403-409
[9]   Variability of blood glucose concentration and short-term mortality in ctitically ill patients [J].
Egi, Moritoki ;
Bellomo, Rinaldo ;
Stachowski, Edward ;
French, Craig J. ;
Hart, Graerne .
ANESTHESIOLOGY, 2006, 105 (02) :244-252
[10]   Is reducing variability of blood glucose the real but hidden target of intensive insulin therapy? [J].
Egi, Moritoki ;
Bellomo, Rinaldo ;
Reade, Michael C. .
CRITICAL CARE, 2009, 13 (02) :302