Contrast-enhanced ultrasound LI-RADS 2017: comparison with CT/MRI LI-RADS

被引:31
作者
Ding, Jianmin [1 ,2 ]
Long, Lei [2 ]
Zhang, Xiang [3 ]
Chen, Chen [3 ]
Zhou, Hongyu [2 ]
Zhou, Yan [2 ]
Wang, Yandong [2 ]
Jing, Xiang [2 ]
Ye, Zhaoxiang [1 ]
Wang, Fengmei [4 ]
机构
[1] Tianjin Med Univ Canc Inst & Hosp, Dept Radiol, Natl Clin Res Ctr Canc, Tianjin Key Lab Canc Prevent & Therapy,Tianjins C, Tianjin, Peoples R China
[2] Tianjin Third Cent Hosp, Tianjin Inst Hepatobiliary Dis, Tianjin Key Lab Artificial Cell,Publ Hlth Minist, Dept Ultrasound,Artificial Cell Engn Technol Res, Tianjin 300170, Peoples R China
[3] Tianjin Third Cent Hosp, Dept Radiol, Tianjin Inst Hepatobiliary Dis,Publ Hlth Minist, Tianjin Key Lab Artificial Cell,Artificial Cell E, Tianjin 300170, Peoples R China
[4] Tianjin Third Cent Hosp, Dept Gastroenterol & Hepatol, Tianjin Inst Hepatobiliary Dis,Publ Hlth Minist, Tianjin Key Lab Artificial Cell,Artificial Cell E, Tianjin 300170, Peoples R China
关键词
Carcinoma; Hepatocellular; Ultrasonography; Tomography; Spiral computed; Magnetic resonance imaging; Contrast agent; HEPATOCELLULAR-CARCINOMA; DATA SYSTEM; AMERICAN-COLLEGE; CEUS; DIAGNOSIS; MRI;
D O I
10.1007/s00330-020-07159-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To compare the classification based on contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) with that of contrast-enhanced CT and MRI (CECT/MRI) LI-RADS for liver nodules in patients at high risk of hepatocellular carcinoma. Methods Two hundred thirty-nine patients with 273 nodules were enrolled in this retrospective study. Each nodule was categorized according to the CEUS LI-RADS version 2017 and CECT/MRI LI-RADS version 2017. The diagnostic performance of CEUS and CECT/MRI was compared. The reference standard was histopathology diagnosis. Inter-modality agreement was assessed with Cohen's kappa. Results The inter-modality agreement for CEUS LI-RADS and CECT/MRI LI-RADS was fair with a kappa value of 0.319 (p < 0.001). The positive predictive values (PPVs) of hepatocellular carcinoma (HCC) in LR-5, LR-4, and LR-3 were 98.3%, 60.0%, and 25.0% in CEUS, and 95.9%, 65.7%, and 48.1% in CECT/MRI, respectively. The sensitivities and specificities of LR-5 for diagnosing HCC were 75.6% and 93.8% in CEUS, and 83.6% and 83.3% in CECT/MRI, respectively. The positive predictive values of non-HCC malignancy in CEUS LR-M and CECT/MRI LR-M were 33.9% and 93.3%, respectively. The sensitivity, specificity, and accuracy for diagnosing non-HCC malignancy were 90.9%, 84.5%, and 85.0% in CEUS LR-M and 63.6%, 99.6%, and 96.7% in CECT/MRI LR-M, respectively. Conclusions The inter-modality agreement of the LI-RADS category between CEUS and CECT/MRI is fair. The positive predictive values of HCCs in LR-5 of the CEUS and CECT/MRI LI-RADS are comparable. CECT/MRI LR-M has better diagnostic performance for non-HCC malignancy than CEUS LR-M.
引用
收藏
页码:847 / 854
页数:8
相关论文
共 22 条
[11]   Management implications and outcomes of LI-RADS-2,-3,-4, and -M category observations [J].
Mitchell, Donald G. ;
Bashir, Mustafa R. ;
Sirlin, Claude B. .
ABDOMINAL RADIOLOGY, 2018, 43 (01) :143-148
[12]   LI-RADS (Liver Imaging Reporting and Data System): Summary, Discussion, and Consensus of the LI-RADS Management Working Group and Future Directions [J].
Mitchell, Donald G. ;
Bruix, Jordi ;
Sherman, Morris ;
Sirlin, Claude B. .
HEPATOLOGY, 2015, 61 (03) :1056-1065
[13]   Hepatocarcinogenesis and LI-RADS [J].
Narsinh, Kazim H. ;
Cui, Jennifer ;
Papadatos, Demetri ;
Sirlin, Claude B. ;
Santillan, Cynthia S. .
ABDOMINAL RADIOLOGY, 2018, 43 (01) :158-168
[14]   American College of Radiology Contrast Enhanced Ultrasound Liver Imaging Reporting and Data System (CEUS LI-RADS) for the diagnosis of Hepatocellular Carcinoma: a pictorial essay [J].
Piscaglia, Fabio ;
Wilson, Stephanie R. ;
Lyshchik, Andrej ;
Cosgrove, David ;
Dietrich, Christoph F. ;
Jang, Hyun-Jung ;
Kim, Tae Kyoung ;
Salvatore, Veronica ;
Willmann, Juergen Karl ;
Sirlin, Claude B. ;
Kono, Yuko .
ULTRASCHALL IN DER MEDIZIN, 2017, 38 (03) :320-324
[15]   Interobserver and intermodality agreement of standardized algorithms for non-invasive diagnosis of hepatocellular carcinoma in high-risk patients: CEUS-LI-RADS versus MRI-LI-RADS [J].
Schellhaas, Barbara ;
Hammon, Matthias ;
Strobel, Deike ;
Pfeifer, Lukas ;
Kielisch, Christian ;
Goertz, Ruediger S. ;
Cavallaro, Alexander ;
Janka, Rolf ;
Neurath, Markus F. ;
Uder, Michael ;
Seuss, Hannes .
EUROPEAN RADIOLOGY, 2018, 28 (10) :4254-4264
[16]   Contrast-Enhanced Ultrasound (CEUS) for the Characterization of Focal Liver Lesions in Clinical Practice (DEGUM Multicenter Trial): CEUS vs. MRI - a Prospective Comparison in 269 Patients [J].
Seitz, K. ;
Bernatik, T. ;
Strobel, D. ;
Blank, W. ;
Friedrich-Rust, M. ;
Strunk, H. ;
Greis, C. ;
Kratzer, W. ;
Schuler, A. .
ULTRASCHALL IN DER MEDIZIN, 2010, 31 (05) :492-499
[17]   CEUS LI-RADS are effective in predicting the risk hepatocellular carcinoma of liver nodules [J].
Terzi, E. ;
De Bonis, L. ;
Leoni, S. ;
Benevento, F. ;
Granito, A. ;
Tovoli, F. ;
Pini, P. ;
Bolondi, L. ;
Piscaglia, F. .
DIGESTIVE AND LIVER DISEASE, 2017, 49 (01) :E22-E22
[18]   Contrast ultrasound LI-RADS LR-5 identifies hepatocellular carcinoma in cirrhosis in a multicenter restropective study of 1,006 nodules [J].
Terzi, Eleonora ;
Iavarone, Massimo ;
Pompili, Maurizio ;
Veronese, Letizia ;
Cabibbo, Giuseppe ;
Fraquelli, Mirella ;
Riccardi, Laura ;
De Bonis, Ludovico ;
Sangiovanni, Angelo ;
Leoni, Simona ;
Zocco, Maria Assunta ;
Rossi, Sandro ;
Alessi, Nicola ;
Wilson, Stephanie R. ;
Piscaglia, Fabio .
JOURNAL OF HEPATOLOGY, 2018, 68 (03) :485-492
[19]   Accuracy of the Liver Imaging Reporting and Data System in Computed Tomography and Magnetic Resonance Image Analysis of Hepatocellular Carcinoma or Overall Malignancy-A Systematic Review [J].
van der Pol, Christian B. ;
Lim, Christopher S. ;
Sirlin, Claude B. ;
McGrath, Trevor A. ;
Salameh, Jean-Paul ;
Bashir, Mustafa R. ;
Tang, An ;
Singal, Amit G. ;
Costa, Andreu F. ;
Fowler, Kathryn ;
McInnes, Matthew D. F. .
GASTROENTEROLOGY, 2019, 156 (04) :976-986
[20]   CEUS LI-RADS: algorithm, implementation, and key differences from CT/MRI [J].
Wilson, Stephanie R. ;
Lyshchik, Andrej ;
Piscaglia, Fabio ;
Cosgrove, David ;
Jang, Hyun-Jung ;
Sirlin, Claude ;
Dietrich, Christoph F. ;
Kim, Tae Kyoung ;
Willmann, Juergen K. ;
Kono, Yuko .
ABDOMINAL RADIOLOGY, 2018, 43 (01) :127-142