Optimization of a gamma imaging probe for axillary sentinel lymph mapping

被引:6
作者
Georgiou, M. [1 ,2 ]
Loudos, G. [2 ]
Stratos, D. [2 ]
Papadimitroulas, P. [3 ]
Liakou, P. [2 ]
Georgoulias, P. [1 ]
机构
[1] Univ Thessaly, Sch Med, Dept Nucl Med, Larisa, Greece
[2] Technol Educ Inst Athens, Dept Med Instruments Technol, Athens, Greece
[3] Univ Patras, Sch Med, Dept Med Phys, Patras, Greece
来源
JOURNAL OF INSTRUMENTATION | 2012年 / 7卷
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Intraoperative probes; STAGE BREAST-CANCER; NODE LOCALIZATION; GUIDED SURGERY; BLUE-DYE; CAMERA; PERFORMANCE; BIOPSY; WOMEN; GATE; US;
D O I
10.1088/1748-0221/7/09/P09010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Sentinel lymph node (SLN) mapping is a technique for assessing whether early-stage invasive breast cancer has metastasized, thus determining prognosis and treatment options. SLN identification is achieved using the blue-dye and radioactive colloids techniques, which are sometimes combined with lymphoscintigraphy. Furthermore, intra-operative gamma acoustic probes, as well as gamma imaging probes are used during surgery. The purpose of this study is the construction of a gamma probe for sentinel lymph node imaging and its optimization in terms of sensitivity with respect to spatial resolution. The reference probe has small field of view (2.5 x 2.5 cm(2)) and is based on a position sensitive photomultiplier tube (PSPMT) coupled to a pixellated CsI(Tl) scintillator. Following experimental validation, we simulated the system using the GATE Monte Carlo toolkit (GATE v6.1) and modeled various collimator geometries, in order to evaluate their performance and propose the optimal configuration. The constraints of the proposed gamma imaging probe are i) sensitivity close to 2 cps/kBq and ii) spatial resolution equal to 6 mm at 2 cm source-to-collimator distance and similar to 10mm at 5 cm. An integrated structure that achieves those requirements is a tungsten collimator with 2 x 2 mm(2)square holes, 16 mm thickness, 0.15 mm septa, where each CsI(Tl) 2 x 2 x 5 mm(3) crystal pixel is placed inside the collimator.
引用
收藏
页数:14
相关论文
共 35 条
[1]   Intradermal blue dye to identify sentinel lymphnode in breast cancer [J].
Borgstein, PJ ;
Meijer, S ;
Pijpers, R .
LANCET, 1997, 349 (9066) :1668-1669
[2]   A method to evaluate intra-operative gamma probes for sentinel lymph node localisation [J].
Britten, AJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (02) :76-83
[3]  
Canavese G, 2000, J SURG ONCOL, V74, P61, DOI 10.1002/1096-9098(200005)74:1<61::AID-JSO14>3.0.CO
[4]  
2-9
[5]  
Collins C. D., 2008, CANC IMAG, V8, P10
[6]   INTRAOPERATIVE BETA-PROBE - A DEVICE FOR DETECTING TISSUE LABELED WITH POSITRON OR ELECTRON EMITTING ISOTOPES DURING SURGERY [J].
DAGHIGHIAN, F ;
MAZZIOTTA, JC ;
HOFFMAN, EJ ;
SHENDEROV, P ;
ESHAGHIAN, B ;
SIEGEL, S ;
PHELPS, ME .
MEDICAL PHYSICS, 1994, 21 (01) :153-157
[7]   Screening for breast cancer [J].
Elmore, JG ;
Armstrong, K ;
Lehman, CD ;
Fletcher, SW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (10) :1245-1256
[8]   A flat-panel-based mini gamma camera for lymph nodes studies [J].
Fernández, MM ;
Benlloch, JM ;
Cerdá, J ;
Escat, B ;
Giménez, EN ;
Giménez, M ;
Lerche, CW ;
Martínez, J ;
Pavón, N ;
Sánchez, F ;
Sebastià, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) :92-96
[9]  
Garibaldi F, 2010, IEEE NUCL SCI CONF R, P2442, DOI 10.1109/NSSMIC.2010.5874226
[10]   Sentinel lymph node as a new marker for therapeutic planning in breast cancer patients [J].
Gipponi, M ;
Bassetti, C ;
Canavese, G ;
Catturich, A ;
Di Somma, C ;
Vecchio, C ;
Nicolò, G ;
Schenone, F ;
Tomei, D ;
Cafiero, F .
JOURNAL OF SURGICAL ONCOLOGY, 2004, 85 (03) :102-111