Comparative Assessment of Gasification Based Coal Power Plants with Various CO2 Capture Technologies Producing Electricity and Hydrogen

被引:32
作者
Mukherjee, Sanjay [1 ]
Kumar, Prashant [1 ]
Hosseini, Ali [2 ]
Yang, Aidong [3 ,4 ]
Fennell, Paul [5 ]
机构
[1] Univ Surrey, Fac Engn & Phys Sci FEPS, Dept Civil & Environm Engn, Guildford GU2 7XH, Surrey, England
[2] Sharif Univ Technol, Sharif Energy Res Inst SERI, Tehran, Iran
[3] Univ Surrey, Dept Chem & Proc Engn, FEPS, Guildford GU2 7XH, Surrey, England
[4] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[5] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn, London SW7 2AZ, England
基金
英国工程与自然科学研究理事会;
关键词
CARBON CAPTURE; CONVERSION; STORAGE; IGCC; COPRODUCTION; EMISSIONS; SYSTEMS; REACTOR; ENERGY;
D O I
10.1021/ef4024299
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Seven different types of gasification-based coal conversion processes for producing mainly electricity and in some cases hydrogen (H-2), with and without carbon dioxide (CO2) capture, were compared on a consistent basis through simulation studies. The flowsheet for each process was developed in a chemical process simulation tool "Aspen Plus". The pressure swing adsorption (PSA), physical absorption (Selexol), and chemical looping combustion (CLC) technologies were separately analyzed for processes with CO2 capture. The performances of the above three capture technologies were compared with respect to energetic and exergetic efficiencies, and the level of CO2 emission. The effect of air separation unit (ASU) and gas turbine (GT) integration on the power output of all the CO2 capture cases is assessed. Sensitivity analysis was carried out for the CLC process (electricity-only case) to examine the effect of temperature and water-cooling of the air reactor on the overall efficiency of the process. The results show that, when only electricity production in considered, the case using CLC technology has an electrical efficiency 1.3% and 2.3% higher than the PSA and Selexol based cases, respectively. The CLC based process achieves an overall CO2 capture efficiency of 99.9% in contrast to 89.9% for PSA and 93.5% for Selexol based processes. The overall efficiency of the CLC case for combined electricity and H-2 production is marginally higher (by 0.3%) than Selexol and lower (by 0.6%) than PSA cases. The integration between the ASU and GT units benefits all three technologies in terms of electrical efficiency. Furthermore, our results suggest that it is favorable to operate the air reactor of the CLC process at higher temperatures with excess air supply in order to achieve higher power efficiency.
引用
收藏
页码:1028 / 1040
页数:13
相关论文
共 43 条
[1]   Exergy analysis of chemical-looping combustion systems [J].
Anheden, M ;
Svedberg, G .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (16-18) :1967-1980
[2]  
[Anonymous], 2007, 3LSEVIER SCI
[3]  
[Anonymous], 2008, International energy outlook
[4]  
[Anonymous], 2002, ADV FOSSIL POWER SYS
[5]  
[Anonymous], 2011, IEA REP COST PERF CA
[6]  
[Anonymous], 2008, ASPEN PLUS IGCC MODE
[7]   Carbon capture and storage update [J].
Boot-Handford, M. E. ;
Abanades, J. C. ;
Anthony, E. J. ;
Blunt, M. J. ;
Brandani, S. ;
Mac Dowell, N. ;
Fernandez, J. R. ;
Ferrari, M. -C. ;
Gross, R. ;
Hallett, J. P. ;
Haszeldine, R. S. ;
Heptonstall, P. ;
Lyngfelt, A. ;
Makuch, Z. ;
Mangano, E. ;
Porter, R. T. J. ;
Pourkashanian, M. ;
Rochelle, G. T. ;
Shah, N. ;
Yao, J. G. ;
Fennell, P. S. .
ENERGY & ENVIRONMENTAL SCIENCE, 2014, 7 (01) :130-189
[8]   Water gas shift membrane reactor for CO2 control in IGCC systems: Techno-economic feasibility study [J].
Bracht, M ;
Alderliesten, PT ;
Kloster, R ;
Pruschek, R ;
Haupt, G ;
Xue, E ;
Ross, JRH ;
Koukou, MK ;
Papayannakos, N .
ENERGY CONVERSION AND MANAGEMENT, 1997, 38 :S159-S164
[9]  
Brockmeier N. F., 1999, HYDROGEN PRODUCTION
[10]   Medium/high temperature water gas shift reaction in a Pd-Ag membrane reactor: an experimental investigation [J].
Brunetti, Adele ;
Drioli, Enrico ;
Barbieri, Giuseppe .
RSC ADVANCES, 2012, 2 (01) :226-233