In vitro evaluation of TiO2 nanotubes as cefuroxime carriers on orthopaedic implants for the prevention of periprosthetic joint infections

被引:42
作者
Chennell, P. [1 ,2 ]
Feschet-Chassot, E. [1 ]
Devers, T. [3 ]
Awitor, K. O. [1 ]
Descamps, S. [1 ,4 ]
Sautou, V. [1 ,2 ]
机构
[1] Univ Auvergne, Univ Clermont Ferrand 2, C BIOSENSS, EA 4676, F-63000 Clermont Ferrand, France
[2] CHU Clermont Ferrand, Serv Pharm, F-63003 Clermont Ferrand, France
[3] Univ Orleans, CNRS, FRE 3520, F-45071 Orleans 02, France
[4] CHU Clermont Ferand, Serv Chirurg Orthoped, F-63003 Clermont Ferrand, France
关键词
Periprosthetic joint infections; Drug delivery systems; Titanium dioxide; Nanotubes; Cefuroxime; ANTIBIOTIC-PROPHYLAXIS; ANODIC ALUMINUM; UNITED-STATES; TOTAL HIP; KNEE; ARTHROPLASTY; DEVICES;
D O I
10.1016/j.ijpharm.2013.07.014
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Context: The prevention of periprosthetic joint infections requires an antibiotic prophylactic therapy, which could be delivered locally using titanium dioxide nanotubes as novel reservoirs created directly on the orthopaedic implant titanium surface. Objective: In this study, the influence of several parameters that could impact the use of titanium dioxide nanotubes as cefuroxime carriers was investigated. Method: Cefuroxime loading and release was studied for 90 min with three nano-topography conditions (nano-smooth, nano-rugged and nano-tubular), two cefuroxime loading solution concentrations (150 mg/mL and 25 mg/mL) and two nano-tubular crystalline structures. Results: In all tested conditions, maximum amount of cefuroxime was obtained within 2 min. For both cefuroxime loading solution concentrations, nano-smooth samples released the least cefuroxime, and the nano-tubular samples released the most, and a six-fold increase in the concentration of the cefuroxime loading increased the amount of cefuroxime quantified by more than seven times, for all tested nano-topographies. However, the nano-tubes' crystalline structure did not have any influence on the amount of cefuroxime quantified. Conclusion: The results demonstrated that the surface nano-topography and loading solution concentration influence the efficiency of titanium dioxide nanotubes as cefuroxime carriers and need to be optimized for use as novel reservoirs for local delivery of cefuroxime to prevent periprosthetic infections. Copyright (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:298 / 305
页数:8
相关论文
共 35 条
[1]   Antibiotic prophylaxis for wound infections in total joint arthroplasty - A systematic review [J].
AlBuhairan, B. ;
Hind, D. ;
Hutchinson, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (07) :915-919
[2]  
Aninwene GE, 2008, INT J NANOMED, V3, P257
[3]   Drug loading of nanoporous TiO2 films [J].
Ayon, Arturo A. ;
Cantu, Michael ;
Chava, Kalpana ;
Agrawal, C. Mauli ;
Feldman, Marc D. ;
Johnson, Dave ;
Patel, Devang ;
Marton, Denes ;
Shi, Emily .
BIOMEDICAL MATERIALS, 2006, 1 (04) :L11-L15
[4]   The significance of infection related to orthopedic devices and issues of antibiotic resistance [J].
Campoccia, D ;
Montanaro, L ;
Arciola, CR .
BIOMATERIALS, 2006, 27 (11) :2331-2339
[5]   The infected total knee - Management options [J].
Cuckler, JM .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :33-36
[6]   Infection after primary hip arthroplasty A comparison of 3 Norwegian health registers [J].
Dale, Havard ;
Skramm, Inge ;
Lower, Hege L. ;
Eriksen, Hanne M. ;
Espehaug, Birgitte ;
Furnes, Ove ;
Skjeldestad, Finn Egil ;
Havelin, Leif I. ;
Engesaeter, Lars B. .
ACTA ORTHOPAEDICA, 2011, 82 (06) :646-654
[7]   Self-ordering electrochemistry: a review on growth and functionality of TiO2 nanotubes and other self-aligned MOx structures [J].
Ghicov, Andrei ;
Schmuki, Patrik .
CHEMICAL COMMUNICATIONS, 2009, (20) :2791-2808
[8]   Antibiotic prophylaxis for surgery for proximal femoral and other closed long bone fractures [J].
Gillespie, William J. ;
Walenkamp, Geert H. I. M. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (03)
[9]   Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection [J].
Gulati, Karan ;
Aw, Moom Sinn ;
Losic, Dusan .
NANOSCALE RESEARCH LETTERS, 2011, 6 :1-6
[10]   Orthopaedic surgeon workforce and volume assessment for total hip and knee replacement in the united states: Preparing for an epidemic [J].
Iorio, Richard ;
Robb, William J. ;
Healy, William L. ;
Berry, Daniel J. ;
Hozack, William J. ;
Kyle, Richard F. ;
Lewallen, David G. ;
Trousdale, Robert T. ;
Jiranek, William A. ;
Stamos, Van P. ;
Parsley, Brian S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07) :1598-1605