Nonenzymatic determination of glucose at near neutral pH values based on the use of nafion and platinum black coated microneedle electrode array

被引:86
作者
Chinnadayyala, Somasekhar R. [1 ]
Park, Ilhwan [2 ]
Cho, Sungbo [2 ,3 ]
机构
[1] Gachon Univ, Dept Biomed Engn, 191 Hambakmoe Ro, Incheon 21936, South Korea
[2] Gachon Univ, Gachon Adv Inst Hlth Sci & Technol, Incheon 21999, South Korea
[3] Gachon Univ, Dept Elect Engn, 1342 Seongnamdaero, Seongnam Si 13120, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Chloroplatinic acid hexahydrate; Lead acetate; Parylene; Polydimethylsiloxane; Electrochemical sensor; Scanning electron microscope; Chronoamperometry; Cyclic voltammetry; Electrodeposition; DRUG-DELIVERY; BIOSENSOR; ENZYME; NANOPARTICLES; FABRICATION; SENSOR;
D O I
10.1007/s00604-018-2770-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors report on a microneedle-based amperometric nonenzymatic glucose sensor for painless and continuous monitoring of glucose. It consists of 3 x 5 sharp stainless steel microneedles micromachined from a stainless steel substrate. The microneedles are 600 and 100 mu m in height and width, respectively. Nafion and platinum black were sequentially coated onto the tip of gold-coated microneedles and used for nonenzymatic (direct) sensing of glucose. Attractive features of the modified microneedle electrode include (a) a low working potential (+0.12 V vs. Ag/AgCl), (b) a linear response in the physiologically relevant range (1-40 mM), (c) a sensitivity as high as 175 mu A mM(-1) cm(-2), (d) a 23 mu M detection limit, and (e) a response time of 2 s. The sensor also exhibits good reproducibility and stability. The sensor is selective for glucose even in the presence of 10-fold higher concentrations of ascorbic acid, lactic acid, dopamine, uric acid, and acetaminophen.
引用
收藏
页数:8
相关论文
共 38 条
[31]   A dually functional 4-aminophenylboronic acid dimer for voltammetric detection of hypochlorite, glucose and fructose [J].
Thiruppathi, Murugan ;
Thiyagarajan, Natarajan ;
Gopinathan, Manavalan ;
Chang, Jen-Lin ;
Zen, Jyh-Myng .
MICROCHIMICA ACTA, 2017, 184 (10) :4073-4080
[32]  
Toghill KE, 2010, INT J ELECTROCHEM SC, V5, P1246
[33]   Non-enzymatic electrochemical sensing of glucose [J].
Wang, Guangfeng ;
He, Xiuping ;
Wang, Lingling ;
Gu, Aixia ;
Huang, Yan ;
Fang, Bin ;
Geng, Baoyou ;
Zhang, Xiaojun .
MICROCHIMICA ACTA, 2013, 180 (3-4) :161-186
[34]   Microneedle array-based carbon paste amperometric sensors and biosensors [J].
Windmiller, Joshua Ray ;
Zhou, Nandi ;
Chuang, Min-Chieh ;
Valdes-Ramirez, Gabriela ;
Santhosh, Padmanabhan ;
Miller, Philip R. ;
Narayan, Roger ;
Wang, Joseph .
ANALYST, 2011, 136 (09) :1846-1851
[35]   Sensing glucose based on its affinity for concanavalin A on a glassy carbon electrode modified with a C60 fullerene nanocomposite [J].
Ye, Cui ;
Zhong, Xia ;
Chai, Yaqin ;
Yuan, Ruo .
MICROCHIMICA ACTA, 2015, 182 (13-14) :2215-2221
[36]   Fabrication of a Microneedle/CNT Hierarchical Micro/Nano Surface Electrochemical Sensor and Its In-Vitro Glucose Sensing Characterization [J].
Yoon, Youngsam ;
Lee, Gil S. ;
Yoo, Koangki ;
Lee, Jeong-Bong .
SENSORS, 2013, 13 (12) :16672-16681
[37]   Ultrasensitive non-enzymatic glucose sensing at near-neutral pH values via anodic stripping voltammetry using a glassy carbon electrode modified with Pt3Pd nanoparticles and reduced graphene oxide [J].
Zhao, Li ;
Wu, Genghuang ;
Cai, Zhixiong ;
Zhao, Tingting ;
Yao, Qiuhong ;
Chen, Xi .
MICROCHIMICA ACTA, 2015, 182 (11-12) :2055-2060
[38]  
Zimmermann S, 2003, SOL STAT SENS ACT MI, P99, DOI [10.1109/SENSOR.2003.1215262, DOI 10.1109/SENS0R.2003.1215262]