Visual Recovery and Endothelial Cell Survival After Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty Grafts-A Cohort Study

被引:17
作者
Tarantino-Scherrer, Janine N. [1 ]
Kaufmann, Claude [1 ]
Bochmann, Frank [1 ]
Bachmann, Lucas M. [2 ]
Thiel, Michael A. [1 ]
机构
[1] Cantonal Hosp Lucerne, Dept Ophthalmol, CH-6000 Luzern 16, Switzerland
[2] Medignition Inc, Res Consultants, Zurich, Switzerland
关键词
DSAEK; failed PK; visual recovery; endothelial cell survival; OUTCOMES; EYES; RISK;
D O I
10.1097/ICO.0000000000000538
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess visual recovery and donor cell survival after Descemet stripping automated endothelial keratoplasty (DSAEK) for the repair of failed penetrating keratoplasty (PK) grafts.Methods:Best spectacle-corrected Snellen visual acuity results after DSAEK were compared with best-ever documented visual acuity (BDVA) results obtained with the previous PK graft in a prospective cohort study. Donor cell survival after DSAEK for PK repair was compared with cell survival after DSAEK for Fuchs endothelial dystrophy and pseudophakic bullous keratopathy. Differences in the logMAR best spectacle-corrected Snellen visual acuity and endothelial cell loss rates were calculated.Results:Twenty-eight eyes with DSAEK for PK repair were identified, 21 of which lacked vision-limiting comorbidities. The mean follow-up was 18.4 10.6 months. At 3 months postoperatively, 10/21 eyes (48%) regained their BDVA. By 24 months, only 14% remained with 0.2 logMAR below their BDVA. Endothelial cell counts decreased significantly faster in patients with DSAEK for failed PK (P = 0.024) or pseudophakic bullous keratopathy (P = 0.018) than in patients with DSAEK for Fuchs endothelial dystrophy.Conclusions:DSAEK for the restoration of failed PK grafts promotes rapid visual recovery within the visual limits of the previous PK graft. Increased endothelial cell loss is noted relative to other DSAEK indications, which may result in earlier endothelial graft failure in renovated PK.
引用
收藏
页码:1024 / 1029
页数:6
相关论文
共 22 条
[1]  
Albert PS, 1999, STAT MED, V18, P1707, DOI 10.1002/(SICI)1097-0258(19990715)18:13<1707::AID-SIM138>3.0.CO
[2]  
2-H
[3]   Descemet's Stripping Endothelial Keratoplasty Under Failed Penetrating Keratoplasty: Visual Rehabilitation and Graft Survival Rate [J].
Anshu, Arundhati ;
Price, Marianne O. ;
Price, Francis W., Jr. .
OPHTHALMOLOGY, 2011, 118 (11) :2155-2160
[4]   Spontaneous Corneal Clearance Despite Graft Detachment in Descemet Membrane Endothelial Keratoplasty [J].
Balachandran, Chandra ;
Ham, Lisanne ;
Verschoor, Christianne A. ;
Ong, T. San ;
Van Der Wees, Jacqueline ;
Melles, Gerrit R. J. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) :227-234
[5]   The profile of repeated corneal transplantation [J].
Bersudsky, V ;
Blum-Hareuveni, T ;
Rehany, U ;
Rumelt, S .
OPHTHALMOLOGY, 2001, 108 (03) :461-469
[6]   Severe retinopathy of prematurity in twin-twin transfusion syndrome after multiple blood transfusions [J].
Chaurasia, Sunita ;
Murthy, Somasheila ;
Ramappa, Muralidhar ;
Mohamed, Ashik ;
Garg, Prashant .
ACTA OPHTHALMOLOGICA, 2014, 92 (02) :167-170
[7]   Clinical Outcome of Repeat Penetrating Keratoplasty [J].
Claesson, Margareta ;
Armitage, W. John .
CORNEA, 2013, 32 (07) :1026-1030
[8]   Retrospective Review of Graft Dislocation Rate Associated With Descemet Stripping Automated Endothelial Keratoplasty After Primary Failed Penetrating Keratoplasty [J].
Clements, John L. ;
Bouchard, Charles S. ;
Lee, W. Barry ;
Dunn, Steven P. ;
Mannis, Mark J. ;
Reidy, James J. ;
John, Thomas ;
Hannush, Sadeer B. ;
Goins, Kenneth M. ;
Wagoner, Michael D. ;
Adi, Marwa A. ;
Rubenstein, Jonathan B. ;
Udell, Ira J. ;
Babiuch, Amy S. .
CORNEA, 2011, 30 (04) :414-418
[9]   Descemet stripping and automated endothelial keratoplasty (DSAEK) in eyes with failed penetrating keratoplasty [J].
Covert, Douglas J. ;
Koenig, Steven B. .
CORNEA, 2007, 26 (06) :692-696
[10]   Descemet Stripping Automated Endothelial Keratoplasty After Failed Penetrating Keratoplasty [J].
Jangi, Anisha A. ;
Ritterband, David C. ;
Wu, Elaine I. ;
Mehta, Veeral V. ;
Koplin, Richard S. ;
Seedor, John A. .
CORNEA, 2012, 31 (10) :1148-1153