Hazardous material analysis using mid wave infrared hyperspectral imaging techniques

被引:7
作者
Ruxton, K. [1 ]
Robertson, G. [1 ]
Miller, B. [1 ]
Malcolm, G. P. A. [1 ]
Maker, G. T. [1 ]
机构
[1] M Squared Lasers Ltd, Glasgow G20 0SP, Lanark, Scotland
来源
CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIV | 2013年 / 8710卷
关键词
Lasers; optical parametric oscillators; stand-off detection proximal detection; IR absorption spectroscopy; hyperspectral imaging; explosives;
D O I
10.1117/12.2017865
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The detection and identification of hazardous material is required in a wide range of application environments including military and civilian. Infrared (IR) absorption spectroscopy is a technique that can be used for material identification through comparing absorption spectra with reference data from a spectral library. The absorption spectrum of a compound is the result of light at certain wavelengths being absorbed through molecular vibrations of the compound. To build on this phenomenon, hyperspectral imaging can be used to add spatial information of the absorber. In this case, the IR source output, an optical parametric oscillator (OPO) operating at 1.5 to 1.7 mu m in the short wave IR (SWIR) and 2.7 to 3.6 mu m in the mid wave IR (MWIR), is raster scanned using a galvanometric mirror pair across a scene of interest. The resulting backscattered light is de-scanned through the same mirror pair and focussed onto point detectors and images in the IR are generated. This hyperspectral imaging instrument is a prototype that is currently being developed for a wide range of applications. If an absorber is present and the OPO wavelength is tuned to an absorption feature of this absorber, this interaction will appear as a dark area in the generated image. With the broad tunability of the OPO, a detailed absorption spectrum of the target compound can be recorded and used to aid material identification. This work presents a selection of results where explosive simulants and materials were investigated and analysed using the prototype instrument.
引用
收藏
页数:8
相关论文
共 5 条
[1]  
Howle C. R., 2011, P SPIE, V8189
[2]  
Oxley J. C., U RHODE ISLAND EXPLO
[3]   CONTINUOUS-WAVE SINGLY RESONANT PUMP-ENHANCED TYPE-II LIB3O5 OPTICAL PARAMETRIC OSCILLATOR [J].
ROBERTSON, G ;
PADGETT, MJ ;
DUNN, MH .
OPTICS LETTERS, 1994, 19 (21) :1735-1737
[4]  
STOTHARD DJM, 2007, P SOC PHOTO-OPT INS, V6737, P673
[5]  
Wallace W.E., NIST Chem WebBook, P20899