Assessment of an iterative reconstruction algorithm (SAFIRE) on image quality in pediatric cardiac CT datasets

被引:108
作者
Han, B. Kelly [1 ,2 ,3 ]
Grant, Katharine L. R. [4 ]
Garberich, Ross [1 ]
Sedlmair, Martin [4 ]
Lindberg, Jana [1 ]
Lesser, John R. [1 ]
机构
[1] Minneapolis Heart Inst & Fdn, Minneapolis, MN 55407 USA
[2] Childrens Heart Clin, Minneapolis, MN USA
[3] Childrens Hosp & Clin Minnesota, Minneapolis, MN USA
[4] Siemens Healthcare, Forchheim, Germany
关键词
Pediatric CT; Dose reduction; Iterative reconstruction; Congenital heart disease; CONGENITAL HEART-DISEASE; DUAL-SOURCE CT; COMPUTED-TOMOGRAPHY; IMPACT; MDCT;
D O I
10.1016/j.jcct.2012.04.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Pediatric cardiac patients often undergo repeat diagnostic testing, resulting in relatively high cumulative medical radiation exposure. Low-dose CT scanning techniques used to decrease radiation exposure may result in reduced image quality. OBJECTIVE: This study evaluates a prototype iterative reconstruction algorithm, sinogram-affirmed iterative reconstruction (SAFIRE), to determine the effect on qualitative and quantitative measures of image quality in pediatric cardiac CT datasets, compared with a standard weighted filtered back projection (wFBP) algorithm. METHODS: Seventy-four datasets obtained on a 128-slice dual-source CT system were evaluated for image quality using both the wFBP and the prototype iterative reconstruction algorithm. Contrast, noise, contrast-to-noise ratio, signal-to-noise ratio, and qualitative image quality were compared between groups. Data were analyzed as medians and 25th and 75th percentiles, and groups were compared with the use of the Wilcoxon singed-rank test or k sample equality of medians test. RESULTS: There was a 34% decrease in noise, a 41% increase in contrast-to-noise ratio, and a 56% increase in signal-to-noise ratio in the prototype iterative reconstruction, compared with wFBP. All differences were statistically significant (P < 0.001). Qualitative measures of image noise and noise texture were also improved in the iterative reconstruction group (P < 0.001 for both). Diagnostic confidence was similar between reconstruction techniques. Median scan dose length product was 15.5 mGy . cm. CONCLUSION: The prototype iterative reconstruction algorithm studied significantly reduces image noise and improves qualitative and quantitative measures of image quality in low-dose pediatric CT datasets, compared with standard wFBP. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 16 条
[1]  
[Anonymous], 1999, EUR GUID QUAL CRIT C
[2]   Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease [J].
Ben Saad, Moez ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Adler, Ghazal ;
Paul, Jean-Francois .
PEDIATRIC RADIOLOGY, 2009, 39 (07) :668-676
[3]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[4]   A review of patient dose and optimisation methods in adult and paediatric CT scanning [J].
Dougeni, E. ;
Faulkner, K. ;
Panayiotakis, G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) :E665-E683
[5]   Image reconstruction and image quality evaluation for a dual source CT scanner [J].
Flohr, T. G. ;
Bruder, H. ;
Stierstorfer, K. ;
Petersilka, M. ;
Schmidt, B. ;
McCollough, C. H. .
MEDICAL PHYSICS, 2008, 35 (12) :5882-5897
[6]   Accuracy and Safety of High Pitch Computed Tomography Imaging in Young Children With Complex Congenital Heart Disease [J].
Han, B. Kelly ;
Lindberg, Jana ;
Grant, Katharine ;
Schwartz, Robert S. ;
Lesser, John R. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (10) :1541-1546
[7]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[8]   Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience [J].
Lell, Michael ;
Marwan, Mohamed ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Flohr, Thomas ;
Allmendinger, Thomas ;
Kalender, Willi ;
Ertel, Dirk ;
Thierfelder, Carsten ;
Kuettner, Axel ;
Ropers, Dieter ;
Daniel, Werner G. ;
Achenbach, Stephan .
EUROPEAN RADIOLOGY, 2009, 19 (11) :2576-2583
[9]   Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality - preliminary findings [J].
Mieville, Frederic A. ;
Gudinchet, Francois ;
Rizzo, Elena ;
Ou, Phalla ;
Brunelle, Francis ;
Bochud, Francois O. ;
Verdun, Francis R. .
PEDIATRIC RADIOLOGY, 2011, 41 (09) :1154-1164
[10]   Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection [J].
Moscariello, Antonio ;
Takx, Richard A. P. ;
Schoepf, U. Joseph ;
Renker, Matthias ;
Zwerner, Peter L. ;
O'Brien, Terrence X. ;
Allmendinger, Thomas ;
Vogt, Sebastian ;
Schmidt, Bernhard ;
Savino, Giancarlo ;
Fink, Christian ;
Bonomo, Lorenzo ;
Henzler, Thomas .
EUROPEAN RADIOLOGY, 2011, 21 (10) :2130-2138