Effect of peripheral perfusion on accuracy of pulse oximetry in children

被引:25
作者
Villanueva, R [1 ]
Bell, C [1 ]
Kain, ZN [1 ]
Colingo, KA [1 ]
机构
[1] Yale Univ, Sch Med, Dept Anesthesiol, New Haven, CT 06520 USA
关键词
equipment; oximeter; monitoring; pulse oximetry; pediatric; perfusion;
D O I
10.1016/S0952-8180(99)00054-9
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To examine the effect of perfusion on accuracy of two pulse oximeters in children and to determine thresholds of perfusion below which these pulse oximeters become inaccurate or cease to function. Design: Prospective, observational clinical study. Setting: Operating room of a large university hospital. Patients: 19 children 10 years of age or less, why were scheduled for general anesthesia with placement of an intraarterial catheter. Interventions: A radial artery catheter, laser Doppler probe, shin temperature sensor and band probes of two oximeters, Ohmeda 3700 (Boulder, CO) and Nellcor N200 (Hayward, CA), were attached to the same hand. Baseline pulse oximeter and Doppler readings were obtained with simultaneous hemoximetry (AVL Model 912 CO-Oxylite, Roswell, GA), skin and esophageal temperatures, total hemoglobin, and transduced arterial pressure. Readings of all parameters (n = 94) were obtained during periods of low perfusion or by occluding the upper arm to 70% to 100% of systolic pressure. Measurements and Main Results: Bias (SpO(2) - SaO(2)) of each oximeter is compared to each perfusion variable (age, weight, core and skin temperature, hemoglobin concentration, pulse pressure, and percent flow by laser Doppler) to determine effect On accuracy. Data were analyzed using backward multivariate linear regression, Pearson correlation coefficients, and independent paired t-test. p < 0.05 was considered significant. Less than 2% bias is seen with either oximeter (Nellcor 1.55 +/- 2.33, Ohmeda 0.78 +/- 2.25). Independent predictors of bias for each machine include weight (r = - 0.376; p < 0.001) and pulse pressure (r = 0.250; p = 0.021) for the Nellcor, and weight (r = - 0.390; p < 0.001), percent flow by Doppler (r = 0.220;p = 0.035), and core temperature (r = 0.307; p = 0.003)for the Ohmeda. However, using-predetermined thresholds for each variable, only skin temperature below 30 degrees C is identified as a significant predictor of oximeter inaccuracy. Conclusions: At the parameters explored in this study, the selected seven perfusion variables (age, weight, core and shin temperature, hemoglobin concentration, pulse pressure, and percent flow by laser Doppler) have little effect on accuracy of pulse oximetry in children. (C) 1999 by Elsevier Science Inc.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [21] THE ACCURACY OF PULSE OXIMETRY AT 2 HEMATOCRIT LEVELS
    VEGFORS, M
    LINDBERG, LG
    OBERG, PA
    LENNMARKEN, C
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (05) : 454 - 459
  • [22] Pulse oximetry and perfusion index measurement to assess uterine perfusion and viability
    Moxey, Paul
    Sieunarine, Krishen
    Cox, Joanne
    Lawson, Andrew D.
    Ungar, Laszlo
    Smith, J. Richard
    INTERNATIONAL SURGERY, 2006, 91 (04) : 223 - 227
  • [23] Accuracy of fetal pulse oximetry and pitfalls in measurements
    Nijland, R
    Jongsma, HW
    Nijhuis, JG
    Oeseburg, B
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S21 - S27
  • [24] Feasibility and accuracy of nasal alar pulse oximetry
    Morey, T. E.
    Rice, M. J.
    Vasilopoulos, T.
    Dennis, D. M.
    Melker, R. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (06) : 1109 - 1114
  • [25] Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery
    Iyer, P
    McDougall, P
    Loughnan, P
    Mee, RBB
    AlTawil, K
    Carlin, J
    CRITICAL CARE MEDICINE, 1996, 24 (03) : 507 - 511
  • [26] Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit
    Seguin, P
    Le Rouzo, A
    Tanguy, M
    Guillou, YM
    Feuillu, A
    Mallédant, Y
    CRITICAL CARE MEDICINE, 2000, 28 (03) : 703 - 706
  • [27] ORAL PULSE OXIMETRY IN SMALL CHILDREN
    LEMA, GE
    ANESTHESIA AND ANALGESIA, 1991, 72 (03) : 414 - 414
  • [28] The effect of patient ethnicity on the accuracy of peripheral pulse oximetry in patients with COVID-19 pneumonitis: a single-centre, retrospective analysis
    Wiles, M. D.
    El-Nayal, A.
    Elton, G.
    Malaj, M.
    Winterbottom, J.
    Gillies, C.
    Moppett, I. K.
    Bauchmuller, K.
    ANAESTHESIA, 2022, 77 (02) : 143 - 152
  • [29] Accuracy analysis of pulse oximetry based on dynamic spectroscopy
    Li Gang
    Li Shang-ying
    Lin Ling
    Wang Yan
    Li Xiao-xia
    Lu Zhi-yang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26 (10) : 1821 - 1824
  • [30] Pulse oximetry: Accuracy of methods of interpreting graphic summaries
    Lafontaine, VM
    Ducharme, FM
    Brouillette, RT
    PEDIATRIC PULMONOLOGY, 1996, 21 (02) : 121 - 131