Identification of fungal clinical isolates by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry

被引:0
作者
Ferreira, Laura [1 ,2 ]
Sanchez-Juanes, Fernando [1 ]
Vega, Silvia [3 ]
Gonzalez, Magdalena [3 ]
Inmaculada Garcia, Ma [2 ,3 ]
Rodriguez, Silvia [1 ]
Manuel Gonzalez-Buitrago, Jose [1 ,2 ,4 ]
Luis Munoz-Bellido, Juan [2 ,3 ,5 ]
机构
[1] Hosp Univ Salamanca, Unidad Invest, Salamanca 37007, Spain
[2] Univ Salamanca, Grp Invest Reconocido MICRAPE, E-37008 Salamanca, Spain
[3] Hosp Univ Salamanca, Microbiol Serv, Salamanca 37007, Spain
[4] Univ Salamanca, Dept Bioquim & Biol Mol, E-37008 Salamanca, Spain
[5] Univ Salamanca, Dept Med Prevent Salud Publ & Microbiol Med, E-37008 Salamanca, Spain
关键词
Moulds; yeasts; identification; mass spectrometry; MALDI-TOF; MICROBIOLOGY LABORATORIES; ROUTINE IDENTIFICATION; BLOOD CULTURE; BACTERIA; CANDIDEMIA; YEAST;
D O I
暂无
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background. Recently, bacterial identification by MALDI-TOF MS has acquired a high relevance in terms of speed and reliability. Conventional mycological identification has some disadvantages: it is frequently slow, reliability is sometimes low, and an extensive experience is required. The risk population for fungal infections, and therefore their clinical significance has progressively increased in recent years. Methods. 153 yeast and mould clinical isolates were analyzed by MALDI-TOF MS and conventional identification. When both methods were discrepant to the genus or species level, ITS-2 sequencing was performed. Results. The correlation in yeasts identification between conventional identification methods and MALDI-TOF MS was extremely high (99.2% to the species level and 1000% to the genus level). The only discrepancy was checked by ITS-2 sequencing and confirmed the MALDI-TOF identification. The correlation in moulds identification was more heterogeneous. 68.70/0 of the isolates showed correlation at least to the genus level and 40.6% to the species level. Therefore, the correlation between conventional identification and MALDI-TOF MS in fungal identification was, In whole, 87% to the species level, and 93.5% to the genus level. Conclusions. Identification of fungi by MALDI-TOF MS is reliable and shows potential advantages over conventional identification methods.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 50 条
[41]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Antimicrobial Susceptibility Testing [J].
Idelevich, Evgeny A. ;
Becker, Karsten .
JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (12)
[42]   Pathology Consultation on Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Microbiology [J].
Wojewoda, Christina .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2013, 140 (02) :143-148
[43]   Optimization of the score cutoff value for routine identification of Staphylococcus species by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry [J].
Han, Huan Wen ;
Chang, Hsien Chang ;
Hunag, Ay Huei ;
Chang, Tsung Chain .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 83 (04) :349-354
[44]   Matrix-assisted laser desorption ionization time-of-flight mass spectrometry: usefulness for taxonomy and epidemiology [J].
Murray, P. R. .
CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (11) :1626-1630
[45]   Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry for species identification of Nonfermenting Gram-Negative Bacilli [J].
Almuzara, Marisa ;
Barberis, Claudia ;
Traglia, German ;
Famiglietti, Angela ;
Soledad Ramirez, Maria ;
Vay, Carlos .
JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 112 :24-27
[46]   Challenging the problem of clostridial identification with matrix-assisted laser desorption and ionization-time-of-flight mass spectrometry (MALDI-TOF MS) [J].
Grosse-Herrenthey, Anke ;
Maier, Thomas ;
Gessler, Frank ;
Schaumann, Reiner ;
Boehnel, Helge ;
Kostrzewa, Markus ;
Krueger, Monika .
ANAEROBE, 2008, 14 (04) :242-249
[47]   Successful Identification of Clinical Dermatophyte and Neoscytalidium Species by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Alshawa, Kinda ;
Beretti, Jean-Luc ;
Lacroix, Claire ;
Feuilhade, Martine ;
Dauphin, Brunhilde ;
Quesne, Gilles ;
Hassouni, Noura ;
Nassif, Xavier ;
Bougnoux, Marie-Elisabeth .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (07) :2277-2281
[48]   Identification of the 'Streptococcus anginosus group' by matrix-assisted laser desorption ionization - time-of-flight mass spectrometry [J].
Woods, Katherine ;
Beighton, David ;
Klein, John L. .
JOURNAL OF MEDICAL MICROBIOLOGY, 2014, 63 :1143-1147
[49]   Evaluation of matrix-assisted laser desorption/ionization time of flight mass spectrometry for the identification of ceratopogonid and culicid larvae [J].
Steinmann, I. C. ;
Pflueger, V. ;
Schaffner, F. ;
Mathis, A. ;
Kaufmann, C. .
PARASITOLOGY, 2013, 140 (03) :318-327
[50]   Identification and Subtyping of Salmonella Isolates Using Matrix-Assisted Laser Desorption-Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF) [J].
Persad, Anil K. ;
Fahmy, Hanan A. ;
Anderson, Nicholas ;
Cui, Jing ;
Topalcengiz, Zeynal ;
Jeamsripong, Saharuetai ;
Spanninger, Patrick M. ;
Buchanan, Robert L. ;
Kniel, Kalmia E. ;
Jay-Russell, Michele T. ;
Danyluk, Michelle D. ;
Rajashekara, Gireesh ;
LeJeune, Jeffrey T. .
MICROORGANISMS, 2022, 10 (04)