Femoral Vein Catheter is an Important Risk Factor for Catheter-related Thrombosis in (Near-)term Neonates

被引:24
作者
Dubbink-Verheij, Gerdina H. [1 ]
Pelsma, Iris C. M. [1 ]
van Ommen, Cornelia H. [2 ]
Smits-Wintjens, Vivianne E. H. J. [1 ]
Visser, Remco [1 ]
Steggerda, Sylke J. [1 ]
te Pas, Arjan B. [1 ]
Lopriore, Enrico [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Pediat, Div Neonatol, Leiden, Netherlands
[2] Erasmus MC Sophia Childrens Hosp, Dept Pediat Hematol, Rotterdam, Netherlands
关键词
central venous catheterization; infant; femoral venous catheter; catheter thrombosis; CENTRAL VENOUS CATHETERS; INTENSIVE-CARE-UNIT; NEWBORN-INFANTS; MANAGEMENT; THROMBOEMBOLISM; COMPLICATIONS; DIAGNOSIS;
D O I
10.1097/MPH.0000000000000978
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Central venous catheters (CVCs) in neonates are associated with an increased risk of thrombosis. Most reports focus on umbilical venous catheters (UVCs) and peripherally inserted central catheters (PICCs), whereas data available on femoral venous catheters (FVCs) are limited. We performed a retrospective cohort study in all neonates (gestational age 34wk) with CVCs. The primary outcome was the occurrence of thrombosis in CVCs. The secondary outcomes were possible risk factors for thrombosis, the thrombotic incidence in FVCs, UVCs, and PICCs, and clinical aspects of thrombosis in these groups. A total of 552 neonates received a total of 656 catheters, including 407 (62%) UVCs, 185 (28%) PICCs, and 64 (10%) FVCs. Thrombosis was detected in 14 cases, yielding an overall incidence of 2.1% or 3.6 events per 1000 catheter days. FVC was significantly associated with the occurrence of thrombosis when compared with UVC (P=0.02; odds ratio, 3.8; 95% confidence interval, 1.2-12.0) and PICC (P=0.01; odds ratio, 8.2; 95% confidence interval, 1.6-41.7). The incidence of thrombosis was higher in FVCs than in UVCs and PICCS, that is, 7.8% (5/64), 1.7% (7/407), and 1.1% (2/185), respectively (P<0.01). The number of thrombotic events per 1000 catheter days was 12.3 in FVCs, 3.2 in UVCs, and 1.5 in PICCs (P<0.05). We concluded that thrombosis occurs more frequently in FVCs than in other CVCs.
引用
收藏
页码:E64 / E68
页数:5
相关论文
共 21 条
[1]   Central venous catheter-associated complications in infants with single ventricle: Comparison of umbilical and femoral venous access routes [J].
Aiyagari, Ranjit ;
Song, Jane Y. ;
Donohue, Janet E. ;
Yu, Sunkyung ;
Gaies, Michael G. .
PEDIATRIC CRITICAL CARE MEDICINE, 2012, 13 (05) :549-553
[2]   Risk factors for hospital-sssociated venous thromboembolism in the neonatal intensive care unit [J].
Amankwah, Ernest K. ;
Atchison, ChristieM. ;
Arlikar, Shilpa ;
Ayala, Irmel ;
Barrett, Laurie ;
Branchford, Brian R. ;
Streiff, Michael ;
Takemoto, Clifford ;
Goldenberg, Neil A. .
THROMBOSIS RESEARCH, 2014, 134 (02) :305-309
[3]  
Bacciedoni V, 2016, ARCH ARGENT PEDIATR, V114, P159, DOI [10.5546/aap.2016.eng.159, 10.5546/aap.2016.159]
[4]   Comparison of catheter-related infection and tip colonization between internal jugular and subclavian central venous catheters in surgical neonates [J].
Breschan, Christian ;
Platzer, Manuela ;
Jost, Robert ;
Schaumberger, Florian ;
Stettner, Haro ;
Likar, Rudolf .
ANESTHESIOLOGY, 2007, 107 (06) :946-953
[5]   A randomized trial comparing long-term and short-term use of umbilical venous catheters in premature infants with birth weights of less than 1251 grams [J].
Butler-O'Hara, Meggan ;
Buzzard, Carol J. ;
Reubens, Linda ;
McDermott, Michael P. ;
DiGrazio, William ;
D'Angio, Carl T. .
PEDIATRICS, 2006, 118 (01) :E25-E35
[6]   A new technique for transumbilical insertion of central venous silicone catheters in newborn infants [J].
Haumont, D. ;
de Beauregard, V. Gouder ;
Van Herreweghe, I. ;
Delanghe, G. ;
Ciardelli, R. ;
Haelterman, E. .
ACTA PAEDIATRICA, 2008, 97 (07) :988-990
[7]   Intravascular catheter complications in the neonatal intensive care unit [J].
Hermansen, MC ;
Hermansen, MG .
CLINICS IN PERINATOLOGY, 2005, 32 (01) :141-+
[8]   Does umbilical vein catheterization lead to portal venous thrombosis? Prospective US evaluation in 100 neonates [J].
Kim, JH ;
Lee, YS ;
Kim, SH ;
Lee, SK ;
Lim, MK ;
Kim, HS .
RADIOLOGY, 2001, 219 (03) :645-650
[9]  
Kloosterman G J, 1969, Ned Tijdschr Verloskd Gynaecol, V69, P349
[10]   Are femoral Broviac catheters effective and safe? A prospective comparison of femoral and jugular venous broviac catheters in newborn infants [J].
Murai, DT .
CHEST, 2002, 121 (05) :1527-1530