Biomechanical comparison of the primary stability of suturing Achilles tendon rupture: a cadaver study of Bunnell and Kessler techniques under cyclic loading conditions

被引:32
作者
Herbort, Mirco [1 ]
Haber, Axel [1 ]
Zantop, Thore [1 ]
Gosheger, Georg [2 ]
Rosslenbroich, Steffen [1 ]
Raschke, Michael J. [1 ]
Petersen, Wolf [1 ]
机构
[1] Univ Munster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
[2] Univ Munster, Dept Orthopaed Surg, D-48149 Munster, Germany
关键词
Achilles tendon; Suture techniques; Cyclic-loading test; Biomechanics; Tendon repair;
D O I
10.1007/s00402-008-0602-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Biomechanical studies investigating suture techniques for Achilles tendon repair used single load to failure tests in order to evaluate the maximal load capacity of the repaired construct. During early rehabilitation the repair is repetitively loaded Such as exercise or daily living activities like walking. Cyclic loading seems to duplicate the physiological loading conditions more closely than single cycle failure tests. Aim of this study was to test the most commonly used Achilles tendon repair techniques (Bunnell and Kessler repair) under cyclic loading conditions. Materials and methods Following tenotomy fresh human cadaveric tendons were sutured either with the Bunnell or Kessler technique. After repair, cyclic loading tests were performed with a uniaxial biomechanical testing machine Lloyd LR-5K Plus. Both groups were Sutured with 0.7 mm PDS. Results Except at maximum load we could not find significant differences between tendons sutured by Bunnell and Kessler techniques. During the cyclic testing there were no differences between both groups with respect to displacement. This applies also to the stiffness of the constructs, which we defined from the load to failure measurements. The failure modes in both groups differed; the tendons repaired by Kessler technique were Cut by the tendons and in the Bunnell group the suture material tore in each specimen tested. Conclusion In our study Bunnell and Kessler techniques showed similar biomechanical properties using the same C suture material. The typical failure mode of the Bunnell technique shows potential to optimise biomechanical behavior by using stronger suture material.
引用
收藏
页码:1273 / 1277
页数:5
相关论文
共 35 条
  • [1] The relative stress on the Achilles tendon during ambulation in an ankle immobiliser: implications for rehabilitation after Achilles tendon repair
    Akizuki, KH
    Gartman, EJ
    Nisonson, B
    Ben-Avi, S
    McHugh, MP
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2001, 35 (05) : 329 - 333
  • [2] Cyclic loading of Achilles tendon repairs: A comparison of polyester and polyblend suture
    Benthien, Ross A.
    Aronow, Michael S.
    Doran-Diaz, Vilmaris
    Sullivan, Raymond J.
    Naujoks, Ryan
    Adams, Douglas J.
    [J]. FOOT & ANKLE INTERNATIONAL, 2006, 27 (07) : 512 - 518
  • [3] Bergljung L, 1968, Scand J Plast Reconstr Surg Suppl, V4, P7
  • [4] Bhandari M, 2002, CLIN ORTHOP RELAT R, P190
  • [5] FACTORS AFFECTING THE STRENGTH OF FLEXOR TENDON REPAIR
    BHATIA, D
    TANNER, KE
    BONFIELD, W
    CITRON, ND
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (05) : 550 - 552
  • [6] Bradley J P, 1992, AORN J, V55, P994, DOI 10.1016/S0001-2092(07)70344-7
  • [7] PERCUTANEOUS AND OPEN SURGICAL REPAIRS OF ACHILLES-TENDON RUPTURES - A COMPARATIVE-STUDY
    BRADLEY, JP
    TIBONE, JE
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1990, 18 (02) : 188 - 195
  • [8] OPERATIVE VERSUS NONOPERATIVE TREATMENT OF ACHILLES-TENDON RUPTURE - A PROSPECTIVE RANDOMIZED STUDY AND REVIEW OF THE LITERATURE
    CETTI, R
    CHRISTENSEN, SE
    EJSTED, R
    JENSEN, NM
    JORGENSEN, U
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) : 791 - 799
  • [9] Current concepts review: Acute ruptures of the Achilles tendon
    Chiodo, CP
    Wilson, MG
    [J]. FOOT & ANKLE INTERNATIONAL, 2006, 27 (04) : 305 - 313
  • [10] CHRISTENSEN I, 1953, ACTA CHIR SCAND, V106, P50