Outcome Associations of Carotid-Femoral Pulse Wave Velocity Vary With Different Measurement Methods

被引:19
作者
Girerd, Nicolas [1 ,2 ]
Legedz, Liliana [1 ]
Paget, Vinciane [1 ]
Rabilloud, Muriel [2 ,3 ]
Milon, Hugues [4 ,5 ]
Bricca, Giampiero [4 ,5 ,6 ]
Lantelme, Pierre [1 ,4 ,5 ]
机构
[1] Hosp Civils Lyon, Croix Rousse Hosp, ESH Hypertens Excellence Ctr, Dept Cardiol, Lyon, France
[2] Hosp Civils Lyon, Dept Biostat, Lyon, France
[3] CNRS, UMR5558, Lab Biometrie & Biol Evolut, Equipe Biotatist Sante, Villeurbanne, France
[4] Univ Lyon 1, EA4173, F-69622 Villeurbanne, France
[5] Hop Nord Ouest, Villefranche, France
[6] Hosp Civils Lyon, Hop Croix Rousse, Metab & Endocrine Explorat Lab, Lyon, France
关键词
blood pressure; cut-off; hypertension; pulse wave velocity; risk stratification; HYPERTENSIVE PATIENTS; AORTIC STIFFNESS; CARDIOVASCULAR MORTALITY; INDEPENDENT PREDICTOR; TASK-FORCE; PRACTICE GUIDELINES; RISK-FACTORS; DISTANCE; MANAGEMENT; DOCUMENT;
D O I
10.1038/ajh.2012.114
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND The impact of various methods of travel distance estimation on the prognostic value of pulse wave velocity (PWV) and on the adequacy of cut-offs has never been addressed within a single population of hypertensive patients. METHODS Four carotid-femoral PWVs were calculated from four different travel distances (Direct, Real, Subtracted, and Estimated) divided by the same travel time in 426 hypertensives (mean age 51.2 +/- 13.8 years, mean systolic blood pressure 155.6 +/- 21.1 mm Hg). The incidence of death from any cause and major cardiovascular events was studied. PWV predictive accuracies were determined using C-index analysis. Hazard ratios (HRs) associated with specific values of PWV were determined with Cox model analyses using cubic splines. RESULTS Mean PWV ranged from 8.3 +/- 2.3 m/s for the Subtracted one to 11.6 +/- 3.0 m/s for the Direct one (P < 0.001). When included as continuous variables in a Cox model, the four PWVs were significantly associated with outcome (all P < 0.001), and had similar C-index (0.608-0.617). In multivariable analysis, the HR calculated for a Direct PWV of 12 m/s was neutral (HR = 1.02). In contrast, the same analysis provided HR ranging from 1.79 to 2.90 with the other PWVs. CONCLUSIONS Different travel distances markedly impact PWV values and prognostic cut-offs. PWV cut-offs should consequently be ascertained jointly with the method of measurement used. There is an urgent need for standardization of PWV assessment before implementing this parameter in the routine management of hypertensives.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 26 条
[21]   Which markers of subclinical organ damage to measure in individuals with high normal blood pressure? [J].
Sehestedt, Thomas ;
Jeppesen, Jorgen ;
Hansen, Tine W. ;
Rasmussen, Susanne ;
Wachtell, Kristian ;
Ibsen, Hans ;
Torp-Pedersen, Christian ;
Olsen, Michael H. .
JOURNAL OF HYPERTENSION, 2009, 27 (06) :1165-1171
[22]   Age-Associated Elongation of the Ascending Aorta in Adults (vol 1, pg 739, 2008) [J].
Sugawara, J. ;
Hayashi, K. ;
Yokoi, T. ;
Tanaka, H. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (03) :378-378
[23]   Comparison of arterial functional evaluations as a predictor of cardiovascular events in hypertensive patients: The non-invasive atherosclerotic evaluation in hypertension (NOAH) study [J].
Terai, Minako ;
Ohishi, Mitsuru ;
Ito, Norihisa ;
Takagi, Takashi ;
Tatara, Yuji ;
Kaibe, Masaharu ;
Komai, Norio ;
Rakugi, Hiromi ;
Ogihara, Toshio .
HYPERTENSION RESEARCH, 2008, 31 (06) :1135-1145
[24]   Distance measurements for the assessment of carotid to femoral pulse wave velocity [J].
Vermeersch, Sebastian J. ;
Rietzschel, Ernst R. ;
De Buyzere, Marc L. ;
Van Bortel, Luc M. ;
Gillebert, Thierry C. ;
Verdonck, Pascal R. ;
Laurent, Stephane ;
Segers, Patrick ;
Boutouyrie, Pierre .
JOURNAL OF HYPERTENSION, 2009, 27 (12) :2377-U2
[25]   Statistics and medicine - The limitations of risk factors as prognostic tools [J].
Ware, James H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (25) :2615-2617
[26]   Noninvasive determination of carotid-femoral pulse wave velocity depends critically on assessment of travel distance: a comparison with invasive measurement [J].
Weber, Thomas ;
Ammer, Marcus ;
Rammer, Martin ;
Adji, Audrey ;
O'Rourke, Michael F. ;
Wassertheurer, Siegfried ;
Rosenkranz, Stefan ;
Eber, Bernd .
JOURNAL OF HYPERTENSION, 2009, 27 (08) :1624-1630