Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery

被引:35
|
作者
Yeo, Tun Kuan [1 ]
Heng, Wee Jin [1 ]
Pek, Don [1 ]
Wong, John [1 ]
Fam, Han Bor [1 ]
机构
[1] Tan Tock Seng Hosp, Natl Healthcare Grp, Eye Inst, Singapore, Singapore
关键词
POSTERIOR CORNEAL ASTIGMATISM; REQUIRING CATARACT-SURGERY; IN-SITU KERATOMILEUSIS; POWER CALCULATION; PREDICTION; ALGORITHM; ERROR;
D O I
10.1038/s41433-020-01159-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives This comparative study aimed to determine if total keratometry (TK) from IOLMaster 700 could be applied to conventional formulas to perform IOL power calculation in eyes with previous myopic laser refractive surgery, and to evaluate their accuracy with known post-laser refractive surgery formulas. Methods Sixty-four eyes of 49 patients with previous myopic laser refractive surgery were evaluated 1 month after cataract surgery. A comparison of the prediction error was made between no clinical history post-laser refractive surgery formulas (Barrett True-K, Haigis-L, Shammas-PL) and conventional formulas (EVO, Haigis, Hoffer Q, Holladay I, and SRK/T) using TK values obtained with the optical biometer IOLMaster 700 (Carl Zeiss Meditec), as well as Barrett True-K with TK. Results The mean prediction error was statistically different from zero for Barrett True-K, Barrett True-K with TK, Haigis-L, Shammas-PL, and Holladay I with TK. The mean absolute error (MAE) was 0.424, 0.671, 0.638, 0.439, 0.408, 0.424, 0.479, 0.647, and 0.524, and median absolute error (MedAE) was 0.388, 0.586, 0.605, 0.298, 0.294, 0.324, 0.333, 0.438, and 0.377 for Barrett True-K, Haigis-L, Shammas-PL, Barrett True-K TK, EVO with TK, Haigis with TK, Hoffer Q with TK, Holladay I with TK, and SRK/T with TK, respectively. EVO TK followed by Barrett True-K TK and Haigis TK achieved the highest percentages of patients with absolute prediction error within 0.50 and 1.00 D (68.75%, 92.19%, and 64.06%, 92.19%, respectively) Conclusions Formulas combined with TK achieve similar or better results compared to existing no-history post-myopic laser refractive surgery formulas.
引用
收藏
页码:1705 / 1711
页数:7
相关论文
共 50 条
  • [1] Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery
    Tun Kuan Yeo
    Wee Jin Heng
    Don Pek
    John Wong
    Han Bor Fam
    Eye, 2021, 35 : 1705 - 1711
  • [2] Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery
    Lawless, Michael
    Jiang, James Y.
    Hodge, Chris
    Sutton, Gerard
    Roberts, Timothy, V
    Barrett, Graham
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (06): : 749 - 756
  • [3] Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery: Response
    Lawless, Michael
    Hodge, Chris
    Sutton, Gerard
    Barrett, Graham
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (01): : 88 - 89
  • [4] Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery: Comment
    Cione, Ferdinando
    De Bernardo, Maddalena
    Capasso, Luigi
    Rosa, Nicola
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 49 (01): : 87 - 88
  • [5] Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery
    Zhao, He
    Chen, Xu
    Liu, Bo
    Liu, Xi
    Liu, Yong
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [6] Accuracy of refractive outcomes using standard or total keratometry for intraocular lens power formulas in conventional cataract surgery
    He Zhao
    Xu Chen
    Bo Liu
    Xi Liu
    Yong Liu
    BMC Ophthalmology, 23 (1)
  • [7] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Ling Wei
    Kaiwen Cheng
    Wenwen He
    Xiangjia Zhu
    Yi Lu
    Eye and Vision, 9
  • [8] Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes
    Wei, Ling
    Cheng, Kaiwen
    He, Wenwen
    Zhu, Xiangjia
    Lu, Yi
    EYE AND VISION, 2022, 9 (01)
  • [9] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [10] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1416 - 1421