Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study

被引:12
|
作者
Perveen, Shuhana [1 ]
Unwin, Danielle [1 ]
Shetty, Amith Loknath [1 ]
机构
[1] Westmead Hosp, Emergency Dept, Sydney, NSW 2145, Australia
关键词
D-dimer; Point of care systems; Pulmonary embolism; Bioequivalence; Length of stay; VENOUS THROMBOEMBOLISM; OUTPATIENTS; ACCURACY;
D O I
10.3343/alm.2013.33.1.34
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: D-dimer is used widely as a diagnostic aid in low- and moderate-risk patients with suspected venous thromboembolism (VTE). While our laboratory utilizes VIDAS D-dimer analyzer (bioMerieux SA, France), our emergency department (ED) recently procured a D-dimer analyzer AQT90 FLEX (Radiometer Medical ApS, Denmark) for point of care testing (FOOT) to facilitate patient management. We aimed to determine whether the time taken to receive D-dimer results using the 2 different analyzers differed significantly and to quantify the limits of agreement between the results of the 2 methods measured on the same patient. Methods: Adult patients presenting to the ED and requiring diagnostic workup for suspected VTE were included in this prospective observational study. Patients underwent simultaneous D-dimer measurements using the 2 different analyzers. Results: The paired results from 104 patients were analyzed. The median time for the D-dimer results from triage by VIDAS was 258 min (Inter-quartile range [IQR], 173-360) and by FOOT was 146 min (IQR, 55-280.5); the median time difference was 101.5 min (IQR, 82-125.5). On an average, FOOT D-dimer values were 15% lower on the same sample (limits of agreement, 34-213%). FOOT predicted 83% of VIDAS positive results (sensitivity, 83.3% [95% confidence interval (CI), 70.4-91.3%]; specificity, 100% [95% CI, 93.6-100%]). All patients with positive imaging were identified correctly by both methods. Conclusions: FOOT delivers D-dimer results in significantly shorter turnaround times than pathology services; however, poor bioequivalence between VIDAS and FOOT raises the issue of acceptability for use in the ED.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [41] How to use D-dimer in acute cardiovascular care
    Giannitsis, Evangelos
    Mair, Johannes
    Christersson, Christina
    Siegbahn, Agneta
    Huber, Kurt
    Jaffe, Allan S.
    Peacock, W. Frank
    Plebani, Mario
    Thygesen, Kristian
    Moeckel, Martin
    Mueller, Christian
    Lindahl, Bertil
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2017, 6 (01) : 69 - 80
  • [42] Performance Evaluation of the Quantitative Point-of-Care LumiraDx d-Dimer Test
    Jayne E. Ellis
    Thomas W. Johnston
    David Craig
    Anita Scribner
    William Simon
    Judith Kirstein
    Cardiology and Therapy, 2021, 10 : 547 - 559
  • [43] The Role of D-dimer Testing in Patients with Suspected Venous Thromboembolism
    Prisco, Domenico
    Grifoni, Elisa
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2009, 35 (01) : 50 - 59
  • [44] Relevance of the CRP levels for D-Dimer-testing in the internal emergency department
    Verma, N.
    Ruebig, E.
    Bicsan, P.
    Pavenstaedt, H.
    Kuempers, P.
    NOTFALL & RETTUNGSMEDIZIN, 2014, 17 (05): : 420 - 426
  • [45] D-dimer testing: advantages and limitations in emergency medicine for managing acute venous thromboembolism
    Siragusa, Sergio
    INTERNAL AND EMERGENCY MEDICINE, 2006, 1 (01) : 59 - 66
  • [46] Analytical performance and user-friendliness of five novel point-of-care D-dimer assays
    Heerink, Jorn
    Gemen, Eugenie
    Oudega, Ruud
    Hopstaken, Rogier
    Geersing, Geert-Jan
    Kusters, Ron
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (05) : 433 - 440
  • [47] Combination pretest probability assessment and D-dimer did not reduce outpatient imaging for venous thromboembolism in a tertiary care hospital emergency department
    Ingber, Sarah
    Selby, Rita
    Lee, Jacques
    Geerts, William
    Brnjac, Elena
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2014, 16 (01) : 53 - 62
  • [48] D-dimer-An International Assessment of the Quality of Laboratory Testing: Implications for D-dimer Use in the Real World
    Elbaz, Carolyne
    Hollestelle, Martine J.
    Meijer, Piet
    Liederman, Zachary
    Selby, Rita
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2024,
  • [49] The diagnostic yield of D-Dimer in relation to time from symptom onset in patients evaluated for venous thromboembolism in the emergency medicine department
    Yelena Goldin
    Oren Pasvolsky
    Ori Rogowski
    Itzhak Shapira
    Arie Steinvil
    Pinchas Halpern
    Jack Serov
    Varda Deutsch
    Galit Aviram
    Shlomo Berliner
    Journal of Thrombosis and Thrombolysis, 2011, 31 : 1 - 5
  • [50] A new rapid point-of-care D-dimer enzyme-linked immunosorbent assay (Stratus CS D-dimer) for the exclusion of venous thromboembolism
    Reber, G
    Bounameaux, H
    Perrier, A
    de Moerloose, P
    BLOOD COAGULATION & FIBRINOLYSIS, 2004, 15 (05) : 435 - 438