Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study

被引:12
|
作者
Perveen, Shuhana [1 ]
Unwin, Danielle [1 ]
Shetty, Amith Loknath [1 ]
机构
[1] Westmead Hosp, Emergency Dept, Sydney, NSW 2145, Australia
关键词
D-dimer; Point of care systems; Pulmonary embolism; Bioequivalence; Length of stay; VENOUS THROMBOEMBOLISM; OUTPATIENTS; ACCURACY;
D O I
10.3343/alm.2013.33.1.34
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: D-dimer is used widely as a diagnostic aid in low- and moderate-risk patients with suspected venous thromboembolism (VTE). While our laboratory utilizes VIDAS D-dimer analyzer (bioMerieux SA, France), our emergency department (ED) recently procured a D-dimer analyzer AQT90 FLEX (Radiometer Medical ApS, Denmark) for point of care testing (FOOT) to facilitate patient management. We aimed to determine whether the time taken to receive D-dimer results using the 2 different analyzers differed significantly and to quantify the limits of agreement between the results of the 2 methods measured on the same patient. Methods: Adult patients presenting to the ED and requiring diagnostic workup for suspected VTE were included in this prospective observational study. Patients underwent simultaneous D-dimer measurements using the 2 different analyzers. Results: The paired results from 104 patients were analyzed. The median time for the D-dimer results from triage by VIDAS was 258 min (Inter-quartile range [IQR], 173-360) and by FOOT was 146 min (IQR, 55-280.5); the median time difference was 101.5 min (IQR, 82-125.5). On an average, FOOT D-dimer values were 15% lower on the same sample (limits of agreement, 34-213%). FOOT predicted 83% of VIDAS positive results (sensitivity, 83.3% [95% confidence interval (CI), 70.4-91.3%]; specificity, 100% [95% CI, 93.6-100%]). All patients with positive imaging were identified correctly by both methods. Conclusions: FOOT delivers D-dimer results in significantly shorter turnaround times than pathology services; however, poor bioequivalence between VIDAS and FOOT raises the issue of acceptability for use in the ED.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [11] USE OF THE D-DIMER FOR DETECTING PULMONARY EMBOLISM IN THE EMERGENCY DEPARTMENT
    Glober, Nancy
    Tainter, Christopher R.
    Brennan, Jesse
    Darocki, Mark
    Klingfus, Morgan
    Choi, Michelle
    Derksen, Brenna
    Rudolf, Frances
    Wardi, Gabriel
    Castillo, Edward
    Chan, Theodore
    JOURNAL OF EMERGENCY MEDICINE, 2018, 54 (05) : 585 - 592
  • [12] D-dimer testing for suspected venous thromboembolism in the emergency department. Consensus document of AcEMC, CISMEL, SIBioC, and SIMeL
    Lippi, Giuseppe
    Cervellin, Gianfranco
    Casagranda, Ivo
    Morelli, Benedetto
    Testa, Sophie
    Tripodi, Armando
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (05) : 621 - 628
  • [13] D-Dimer Tests in the Emergency Department: Current Insights
    Innocenti, Francesca
    Lazzari, Cristian
    Ricci, Francesca
    Paolucci, Elisa
    Agishev, Ilya
    Pini, Riccardo
    OPEN ACCESS EMERGENCY MEDICINE, 2021, 13 : 465 - 479
  • [14] ICSH guidance for INR and D-dimer testing using point of care testing in primary care
    Fitzmaurice, David A.
    Geersing, Geert-Jan
    Armoiry, Xavier
    Machin, Sam
    Kitchen, Steve
    Mackie, Ian
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 (03) : 276 - 281
  • [15] Prospective diagnostic accuracy assessment of the HemosIL HS D-dimer to exclude pulmonary embolism in emergency department patients
    Courtney, D. Mark
    Steinberg, Justin M.
    McCormick, Jennifer C.
    THROMBOSIS RESEARCH, 2010, 125 (01) : 79 - 83
  • [16] Update of D-dimer testing
    Rosler, Alexander Eduard
    Orth, Matthias
    LABORATORIUMSMEDIZIN-JOURNAL OF LABORATORY MEDICINE, 2012, 36 (02): : 65 - 75
  • [17] Diagnostic performance and predictive value of D-dimer testing in patients referred to the emergency department for suspected myocardial infarction
    Koch, Vitali
    Booz, Christian
    Gruenewald, Leon D.
    Albrecht, Moritz H.
    Gruber-Rouh, Tatjana
    Eichler, Katrin
    Yel, Ibrahim
    Mahmoudi, Scherwin
    Scholtz, Jan-Erik
    Martin, Simon S.
    Graf, Christiana
    Vogl, Thomas J.
    Weber, Christophe
    Hardt, Stefan E.
    Frey, Norbert
    Giannitsis, Evangelos
    CLINICAL BIOCHEMISTRY, 2022, 104 : 22 - 29
  • [18] "What is it that really counts"? Response to concerns regarding the applicability of D-dimer point-of-care devices in the emergency department
    Heerink, Jorn S.
    THROMBOSIS RESEARCH, 2024, 238 : 184 - 184
  • [19] Is D-dimer Test Cost Effective and Time Sensitive for Diagnosis of Venous Thromboembolism in Emergency Department?
    White, Lucia M.
    Sarkar, Mayukh K.
    CLINICAL LABORATORY, 2023, 69 (01) : 199 - 208
  • [20] Bedside measurement of D-dimer in the identification of bacteremia in the Emergency Department
    Quick, G
    Eisenberg, P
    JOURNAL OF EMERGENCY MEDICINE, 2000, 19 (03) : 217 - 223