The Influence of Orthokeratology on Intraocular Pressure Measurements

被引:9
|
作者
Chang, Chia-Jen [1 ,3 ]
Yang, Hsi-Hsien [1 ]
Chang, Chin-An [1 ]
Wu, Richard [2 ]
Tsai, Hsien-Yang [3 ]
机构
[1] Chaoyang Univ Technol, Grad Inst Biochem Sci & Technol, Taichung 40644, Taiwan
[2] Cent Taiwan Univ Sci & Technol, Dept Optometry, Taichung, Taiwan
[3] Execut Yuan, Vet Affairs Commiss, Taichung Vet Gen Hosp, Dept Ophthalmol, Taichung, Taiwan
关键词
Central corneal thickness; intraocular pressure; myopia; orthokeratology; tonometry; DYNAMIC CONTOUR TONOMETER; CENTRAL CORNEAL THICKNESS; GOLDMANN APPLANATION; LENS WEAR; PNEUMOTONOMETRY; CURVATURE; GLAUCOMA;
D O I
10.3109/08820538.2013.768679
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Underestimation of IOP in a myopic patient may lead to misjudgment of the risk of glaucoma. This study investigated the influence of orthokeratology-induced change in CCT on IOP measured by the non-contact pneumotonometer (NCT), Goldmann applanation tonometer (GAT), and Pascal dynamic contour tonometer (PDCT). Methods: This study was conducted to examine the eyes of 34 patients who received orthokeratology for myopia. CCT and IOP were measured, and IOP was obtained with the NCT, GAT, and PDCT. The associations between changes in measured IOP and change in CCT at different orthokeratology follow-up time points were evaluated by linear regression analysis. Results: Change in IOP measured by the three tonometries correlated significantly with change in CCT after one-week application of orthokeratology. The correlation was strongest for NCT followed by GAT and PDCT. The changes in measured IOP corresponding to a 10 mm decrease in CCT were 0.7-0.9, 0.4-0.6, and 0.2-0.3 mm Hg for NCT, GAT, and PDCT, respectively. Conclusions: The IOP measured by the three methods - NCT, GAT, and PDCT - decreased as a result of the change in CCT induced by orthokeratology. The influence on NCT and GAT was greater than that on PDCT.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [1] Decrease in intraocular pressure following orthokeratology measured with a noncontact tonometer
    Ishida, Yasuhito
    Yanai, Ryoji
    Sagara, Takeshi
    Nishida, Teruo
    Toshida, Hiroshi
    Murakami, Akira
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (03) : 190 - 195
  • [2] Decrease in intraocular pressure following orthokeratology measured with a noncontact tonometer
    Yasuhito Ishida
    Ryoji Yanai
    Takeshi Sagara
    Teruo Nishida
    Hiroshi Toshida
    Akira Murakami
    Japanese Journal of Ophthalmology, 2011, 55 : 190 - 195
  • [3] Intraocular pressure measurements throughout the 24 h
    Bagga, Harmohina
    Liu, John H. K.
    Weinreb, Robert N.
    CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (02) : 79 - 83
  • [4] Underestimation of Intraocular Pressure After Orthokeratology
    Yanai, R.
    Ishida, Y.
    Sagara, T.
    Suzuki, K.
    Chikama, T. -I.
    Nishida, T.
    Toshida, H.
    Murakami, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Intraocular Pressure, Ethnicity, and Refractive Error
    Manny, Ruth E.
    Mitchell, G. Lynn
    Cotter, Susan A.
    Jones-Jordan, Lisa A.
    Kleinstein, Robert N.
    Mutti, Donald O.
    Twelker, J. Daniel
    Zadnik, Karla
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (12) : 1445 - 1453
  • [6] Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer
    Kopito, Robert
    Gaujoux, Thomas
    Montard, Romain
    Touzeau, Olivier
    Allouch, Cecile
    Borderie, Vincent
    Laroche, Laurent
    ACTA OPHTHALMOLOGICA, 2011, 89 (03) : e225 - e230
  • [7] Does patient comfort influence the choice of tonometer for the measurement of intraocular pressure?
    Ugalahi, Mary O.
    Seidu, Mukaila A.
    Olusanya, Bolutife A.
    Baiyeroju, Aderonke M.
    INTERNATIONAL OPHTHALMOLOGY, 2016, 36 (03) : 385 - 389
  • [8] Measuring intraocular pressure
    Okafor, Kingsley C.
    Brandt, James D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (02) : 103 - 109
  • [9] Intraocular pressure measurements in diabetes mellitus
    Ramm, Lisa
    Herber, Robert
    Spoerl, Eberhard
    Pillunat, Lutz E.
    Terai, Naim
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) : 1432 - 1439
  • [10] Stop "Adjusting" Intraocular Pressure Measurements
    Brandt, James D.
    JAMA OPHTHALMOLOGY, 2017, 135 (06) : 608 - 609