Magnetic Resonance Imaging Identifies Multifocal and Multicentric Disease in Breast Cancer Patients Who Are Eligible for Partial Breast Irradiation

被引:46
作者
Al-Hallaq, Hania A. [1 ]
Mell, Loren K. [1 ]
Bradley, Julie A. [1 ]
Chen, Lucy F. [1 ]
Ali, Arif N. [1 ]
Weichselbaum, Ralph R. [1 ]
Newstead, Gillian M. [2 ]
Chmura, Steven J. [1 ]
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
breast cancer; magnetic resonance imaging; radiotherapy; whole-breast irradiation; partial breast irradiation;
D O I
10.1002/cncr.23872
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BACKGROUND. In this retrospective study, the authors hypothesized that magnetic resonance imaging (MRI) would alter partial breast irradiation (PBI) eligibility by identifying cancers outside the PBI volume compared with mammography alone. METHODS. Since 2002, MRI was used nonselectively at the authors' instittition for the staging of patients with nonmetastatic breast cancer. Of 450 consecutive Patients with invasive breast cancer, 110 patients who were eligible for PBI were identified by Using criteria outlined by National Surgical Adjuvant Breast and Rowel Project B-39/Radiation Oncology Group trial 0413 based on mammography ultrasonography, and initial pathology. In that trial, patients were randomized (stage I/II invasive cancers that measured <= 3 cm and <= 3 positive lymph nodes) to receive either whole-breast radiotherapy or PBI. MRI reports were reviewed to determine whether MRI identified secondary lesions 1) within the same quadrant (multifocal), 2) in a different quadrant (multicentric), or 3) in the contralateral breast. These lesions were pathologically proven carcinoma and would have rendered the patient ineligible for PBI. RESULTS. MRI identified secondary lesions in 10%, of patients (95% confidence interval [CI], 4.4%-15.6%). Multifocal disease was identified in 3.6% (95% CI, 1.4%-9%), multicentric disease was identified in 4.5% (95% CI, 2%-10.2%), and contralateral disease was identified in 1.8% (95% CI, 0.5%-6.4%). The proportion of patients with false-positive Mill findings was 4.5% (95% CI, 2%-10.2%). The positive predictive value of MRI was 72.2% (95% CI, 46.4%-89.3%). CONCLUSIONS. MRI identified frequent secondary cancers that would not be removed routinely by surgery or targeted in the radiation field if treated with PBI. The current data suggest that MRI should be considered to assess PBI eligibility to minimize potential local failures. Cancer 2008;113:2408-14. (C) 2008 American Cancer Society.
引用
收藏
页码:2408 / 2414
页数:7
相关论文
共 21 条
  • [1] Abe O, 2005, LANCET, V365, P1687, DOI 10.1016/s0140-6736(05)66544-0
  • [2] Impact of a higher radiation dose on local control and survival in breast-conserving therapy of early breast cancer:: 10-year results of the randomized boost versus no boost EORTC 22881-10882 trial
    Bartelink, Harry
    Horiot, Jean-Claude
    Poortmans, Philip M.
    Struikmans, Henk
    Van den Bogaert, Walter
    Fourquet, Alain
    Jager, Jos J.
    Hoogenraad, Willem J.
    Oei, S. Bing
    Warlam-Rodenhuis, Carla C.
    Pierart, Marianne
    Collette, Laurence
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (22) : 3259 - 3265
  • [3] Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer
    Berg, WA
    Gutierrez, L
    NessAiver, MS
    Carter, WB
    Bhargavan, M
    Lewis, RS
    Ioffe, OB
    [J]. RADIOLOGY, 2004, 233 (03) : 830 - 849
  • [4] Utility of magnetic resonance imaging in the management of breast cancer: Evidence for improved preoperative staging
    Esserman, L
    Hylton, N
    Yassa, L
    Barclay, J
    Frankel, S
    Sickles, E
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (01) : 110 - 119
  • [5] Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer
    Fisher, B
    Anderson, S
    Bryant, J
    Margolese, RG
    Deutsch, M
    Fisher, ER
    Jeong, J
    Wolmark, N
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (16) : 1233 - 1241
  • [6] Differentiation of benign and malignant sub-1 cm breast lesions using dynamic contrast enhanced MRI
    Gibbs, P
    Liney, GP
    Lowry, M
    Kneeshaw, PJ
    Turnbull, LW
    [J]. BREAST, 2004, 13 (02) : 115 - 121
  • [7] HOLLAND R, 1985, CANCER, V56, P979, DOI 10.1002/1097-0142(19850901)56:5<979::AID-CNCR2820560502>3.0.CO
  • [8] 2-N
  • [9] Lalonde L, 2005, CAN ASSOC RADIOL J, V56, P301
  • [10] MRI evaluation of the contralateral breast in women with recently diagnosed breast cancer
    Lehman, Constance D.
    Gatsonis, Constantine
    Kuhl, Christiane K.
    Hendrick, R. Edward
    Pisano, Etta D.
    Hanna, Lucy
    Peacock, Sue
    Smazal, Stanley F.
    Maki, Daniel D.
    Julian, Thomas B.
    DePeri, Elizabeth R.
    Bluemke, David A.
    Schnall, Mitchell D.
    Julian, T.
    Poller, W.
    Schilling, K.
    Neal, C.
    Wichterman, L.
    Seifert, P.
    O'Loughlin, M.
    Bluemke, D.
    Kawamoto, S.
    DePeri, E.
    Hendrick, E.
    Wolfman, J.
    Smazal, S.
    Thickman, D.
    Korn, R.
    Maki, D.
    Whitfill, C.
    Cook, A.
    Causer, P.
    Rao, V.
    Piccoli, C.
    Ferris, E.
    Harms, S.
    Kuhl, C.
    DeBruhl, N.
    Hylton, N.
    Mahoney, M.
    Pisano, E.
    Schnall, M.
    Weinstein, S.
    Keesara, S.
    Weatherall, P.
    DeAngelis, G.
    Lehman, C.
    Li, T.
    Soulen, R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (13) : 1295 - 1303