Detection limit of methods to assess fluid status changes in dialysis patients

被引:107
作者
Kraemer, M
Rode, C
Wizemann, V
机构
[1] Fresenius Biotech GmbH, D-61352 Bad Homburg, Germany
[2] Georg Haas Dialysezentrum, Giessen, Germany
关键词
hemodialysis; fluid status; dry weight; bioimpedance; vena cava; extracellular volume;
D O I
10.1038/sj.ki.5000286
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Technical systems for an accurate and practicable fluid management of dialysis patients are urgently needed, since current clinical methods are partially subjective, imprecise, and time consuming. Such new systems should not only allow the determination of the target normohydration weight, but also must be able to detect clinically relevant changes in fluid volume (similar to 1 l). This study focuses on the systematic analysis of the detection limit of several candidate methods for fluid management. In a cohort of 16 new dialysis patients, several candidate methods were applied in parallel during each treatment of the initial weight reduction phase: the measurement of vena cava diameter (VCD), vena cava collapsibility index (CI), the blood volume drop during an ultrafiltration (UF) bolus (Delta relative blood volume (RBV) -), the rebound after the UF bolus (Delta RBV+), and the extracellular fluid volume determined with whole body bioimpedance spectroscopy (BIS). A clinical reference method was used to manage the fluid status of patients. All methods showed significant correlations with predialysis weight. The detection limits W-lim of candidate methods for changes in fluid status were assessed as W-lim = 0.87 kg +/- 0.64 kg (BIS), 1.74 kg +/- 1.56 kg (VCD), 2.3 kg +/- 1.0 kg (Delta RBV-), 7.4 kg +/- 8.5 kg (CI), 40 kg7108 kg (Delta RBV+). Only BIS shows a satisfactorily low detection limit Wlim, whereas Wlim was rated as critical for the VCD and Delta RBV- methods, and as unacceptable for the CI and Delta RBV_ methods. Bioimpedance spectroscopy appears to be the most promising method for a practical fluid management system in dialysis.
引用
收藏
页码:1609 / 1620
页数:12
相关论文
共 48 条
[1]  
ACKMANN JJ, 1984, CRIT REV BIOMED ENG, V11, P281
[2]   The inferior vena cava diameter as a marker of dry weight in chronic hemodialyzed patients [J].
Ando, Y ;
Yanagiba, S ;
Asano, Y .
ARTIFICIAL ORGANS, 1995, 19 (12) :1237-1242
[3]   A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance [J].
Chamney, PW ;
Krämer, M ;
Rode, C ;
Kleinekofort, W ;
Wizemann, V .
KIDNEY INTERNATIONAL, 2002, 61 (06) :2250-2258
[4]   Fluid balance modelling in patients with kidney failure [J].
Chamney, PW ;
Johner, C ;
Aldridge, C ;
Krämer, M ;
Valasco, N ;
Tattersall, JE ;
Aukaidey, T ;
Gordon, R ;
Greenwood, RN .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1999, 23 (02) :45-52
[5]  
Charra B, 1993, ASAIO J, V39, P819, DOI 10.1097/00002480-199310000-00001
[6]   'Dry weight' in dialysis: the history of a concept [J].
Charra, B .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (07) :1882-1885
[7]  
Charra B, 1996, NEPHROL DIAL TRANSPL, V11, P16
[8]   Importance of treatment time and blood pressure control in achieving long-term survival on dialysis [J].
Charra, B ;
Calemard, E ;
Laurent, G .
AMERICAN JOURNAL OF NEPHROLOGY, 1996, 16 (01) :35-44
[9]  
CHERIEX EC, 1989, NEPHROL DIAL TRANSPL, V4, P563
[10]   Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558