Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures

被引:21
|
作者
Oberst, Michael [1 ]
Hauschild, Oliver [2 ]
Konstantinidis, Lukas [2 ]
Suedkamp, Norbert P. [2 ]
Schmal, Hagen [2 ]
机构
[1] Ostalb Klinikum Aalen, Clin Orthopaed Trauma & Spine Surg, D-73430 Aalen, Germany
[2] Univ Hosp Freiburg, Dept Orthopaed & Traumatol, Freiburg, Germany
关键词
Acetabulum; fracture; navigation; ORIF; OPERATIVE TREATMENT; SCREW PLACEMENT; CLASSIFICATION; SURGERY; COMPLEX; POSITION;
D O I
10.1097/TA.0b013e318254308f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: This study was conducted to evaluate whether intraoperative procedure and/or early postoperative results after open reduction and internal fixation (ORIF) of displaced acetabulum fractures are influenced by the use of a three-dimensional (3D) image intensifier in combination with a navigation system. METHODS: From January 2004 until December 2008, all patients with acetabular fractures were followed prospectively. From January 2004 until October 2006, all operations were performed under fluoroscopic control using a conventional two-dimensional image intensifier. Since October 2006, we regularly operate acetabular fractures with the intraoperative use of a navigation system and a 3D image intensifier. Pre- and postoperative computed tomography scans of the affected hip were obtained in all patients as were standard anterior-posterior radiographs and ala-and obturator views. All data collection was performed according to the guidelines of the "German Pelvic fracture study group." RESULTS: In total, 68 patients with acetabular fractures were included in the study. A conventional image intensifier was used in 37 patients (group A) and a 3D image-based navigation was used in the remaining 31 patients (group B). In the navigated group, seven patients were assessed incapable of partial weight bearing. These patients underwent computer-assisted percutaneous screwing of their acetabular fracture. Using a navigation system in combination with a 3D image intensifier for ORIF of displaced acetabular fractures led to a significant increase in skin-to-skin time. Postoperative radiolographic analysis revealed an improvement in the quality of fracture reduction in the 3D navigation group. Navigation in combination with the 3D images of the ISO-C 3D limited the need for extended approaches. In addition, the complication rate in the navigated group was significantly lower. CONCLUSION: We support the use of navigation systems and a 3D image intensifier as helpful tools during ORIF of displaced acetabular fractures. (J Trauma Acute Care Surg. 2012; 73: 950-956. Copyright (C) 2012 by Lippincott Williams & Wilkins)
引用
收藏
页码:950 / 956
页数:7
相关论文
共 38 条
  • [31] Open reduction and internal fixation of modified Mason type III/IV radial head fractures with more than three fragments: an analysis of the clinical outcome and reoperation rate
    Helmstetter, Timothee
    Maniglio, Mauro
    Fornaciari, Paolo
    Tannast, Moritz
    Vial, Philippe
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (02) : 1121 - 1130
  • [32] Functional outcome of displaced intra-articular calcaneal fractures: A comparison between open reduction/internal fixation and a minimally invasive approach featured an anatomical plate and compression bolts
    Wu, Zhanpo
    Su, Yanling
    Chen, Wei
    Zhang, Qi
    Liu, Yueju
    Li, Ming
    Wang, Haili
    Zhang, Yingze
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (03) : 743 - 751
  • [33] Part 2: outcome of acetabular fractures and associated prognostic factors—a ten-year retrospective study of one hundred and fifty six operated cases with open reduction and internal fixation
    Mehdi Boudissa
    Sébastien Ruatti
    Gael Kerschbaumer
    Michel Milaire
    Philippe Merloz
    Jérôme Tonetti
    International Orthopaedics, 2016, 40 : 2151 - 2156
  • [34] Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty
    Laurer, Helmut L.
    Wutzler, Sebastian
    Possner, Susann
    Geiger, Emanuel V.
    El Saman, Andre
    Marzi, Ingo
    Frank, Johannes
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (07) : 983 - 989
  • [35] Part 2: outcome of acetabular fractures and associated prognostic factors-a ten-year retrospective study of one hundred and fifty six operated cases with open reduction and internal fixation
    Boudissa, Mehdi
    Ruatti, Sebastien
    Kerschbaumer, Gael
    Milaire, Michel
    Merloz, Philippe
    Tonetti, Jerome
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (10) : 2151 - 2156
  • [36] Proximal humerus fractures (PHFs): comparison of functional outcome 1 year after minimally invasive plate osteosynthesis (MIPO) versus open reduction internal fixation (ORIF)
    Buchmann, Laura
    van Lieshout, Esther M. M.
    Zeelenberg, Miliaan
    den Hartog, Dennis
    Pfeifer, Roman
    Allemann, Florin
    Pape, Hans-Christoph
    Halvachizadeh, Sascha
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (06) : 4553 - 4558
  • [37] Proximal humerus fractures (PHFs): comparison of functional outcome 1 year after minimally invasive plate osteosynthesis (MIPO) versus open reduction internal fixation (ORIF)
    Laura Buchmann
    Esther M. M. van Lieshout
    Miliaan Zeelenberg
    Dennis den Hartog
    Roman Pfeifer
    Florin Allemann
    Hans-Christoph Pape
    Sascha Halvachizadeh
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 4553 - 4558
  • [38] Proximal Humerus Fractures in the Elderly US Population: A Cross-Sectional Study of Treatment Trends and Comparison of Complication Rates after Joint Replacement, Open Reduction and Internal Fixation, and Non-Surgical Management
    Walter, Nike
    Szymski, Dominik
    Riedl, Moritz
    Kurtz, Steven M.
    Alt, Volker
    Lowenberg, David W.
    Lau, Edmund C.
    Rupp, Markus
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (10)