Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures

被引:21
|
作者
Oberst, Michael [1 ]
Hauschild, Oliver [2 ]
Konstantinidis, Lukas [2 ]
Suedkamp, Norbert P. [2 ]
Schmal, Hagen [2 ]
机构
[1] Ostalb Klinikum Aalen, Clin Orthopaed Trauma & Spine Surg, D-73430 Aalen, Germany
[2] Univ Hosp Freiburg, Dept Orthopaed & Traumatol, Freiburg, Germany
关键词
Acetabulum; fracture; navigation; ORIF; OPERATIVE TREATMENT; SCREW PLACEMENT; CLASSIFICATION; SURGERY; COMPLEX; POSITION;
D O I
10.1097/TA.0b013e318254308f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: This study was conducted to evaluate whether intraoperative procedure and/or early postoperative results after open reduction and internal fixation (ORIF) of displaced acetabulum fractures are influenced by the use of a three-dimensional (3D) image intensifier in combination with a navigation system. METHODS: From January 2004 until December 2008, all patients with acetabular fractures were followed prospectively. From January 2004 until October 2006, all operations were performed under fluoroscopic control using a conventional two-dimensional image intensifier. Since October 2006, we regularly operate acetabular fractures with the intraoperative use of a navigation system and a 3D image intensifier. Pre- and postoperative computed tomography scans of the affected hip were obtained in all patients as were standard anterior-posterior radiographs and ala-and obturator views. All data collection was performed according to the guidelines of the "German Pelvic fracture study group." RESULTS: In total, 68 patients with acetabular fractures were included in the study. A conventional image intensifier was used in 37 patients (group A) and a 3D image-based navigation was used in the remaining 31 patients (group B). In the navigated group, seven patients were assessed incapable of partial weight bearing. These patients underwent computer-assisted percutaneous screwing of their acetabular fracture. Using a navigation system in combination with a 3D image intensifier for ORIF of displaced acetabular fractures led to a significant increase in skin-to-skin time. Postoperative radiolographic analysis revealed an improvement in the quality of fracture reduction in the 3D navigation group. Navigation in combination with the 3D images of the ISO-C 3D limited the need for extended approaches. In addition, the complication rate in the navigated group was significantly lower. CONCLUSION: We support the use of navigation systems and a 3D image intensifier as helpful tools during ORIF of displaced acetabular fractures. (J Trauma Acute Care Surg. 2012; 73: 950-956. Copyright (C) 2012 by Lippincott Williams & Wilkins)
引用
收藏
页码:950 / 956
页数:7
相关论文
共 38 条
  • [11] Early Protected Weightbearing after Open Reduction Internal Fixation of Ankle Fractures
    Starkweather, Michael P.
    Collman, David R.
    Schuberth, John M.
    JOURNAL OF FOOT & ANKLE SURGERY, 2012, 51 (05) : 575 - 578
  • [12] The Combined Hip Procedure: Open Reduction Internal Fixation Combined With Total Hip Arthroplasty for the Management of Acetabular Fractures in the Elderly
    Herscovici, Dolfi, Jr.
    Lindvall, Eric
    Bolhofner, Brett
    Scaduto, Julia M.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (05) : 291 - 296
  • [13] Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre
    Chui, King Him
    Chau, Chi Chiu Dennis
    Ip, Ka Chun
    Lee, Kin Bong
    Li, Wilson
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (06) : 1387 - 1395
  • [14] Surgical resection of severe heterotopic ossification after open reduction and internal fixation of acetabular fractures: A case series of 18 patients
    Wu, Xin-Bao
    Yang, Ming-Hui
    Zhu, Shi-Wen
    Cao, Qi-Yong
    Wu, Hong-Hua
    Wang, Man-Yi
    Cuellar, Derly O., III
    Mauffrey, Cyril
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (10): : 1604 - 1610
  • [15] Radiological and Functional Assessment of Treatment Outcomes in Patients after Open Reduction with Internal Fixation (ORIF) of Acetabular Fractures
    Dadura, Emilia
    Truszczynska-Baszak, Aleksandra
    Szydlowski, Dariusz
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (03)
  • [16] Laxity and functional outcome after arthroscopic reduction and internal fixation of displaced tibial spine fractures in children
    Kocher, MS
    Foreman, ES
    Micheli, LJ
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (10) : 1085 - 1090
  • [17] Three-Dimensional Navigation-Assisted Open Reduction and Internal Fixation of a Subcondylar and Ramus Fracture on a Maxillary Oligodontia Patient
    Ng, Kwan-Lok B.
    Liu, Tsung-Hsien
    Lee, Su-Shin
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (02) : e114 - e116
  • [18] Postoperative chest radiograph after open reduction internal fixation of clavicle fractures: a necessary practice?
    Shubert, Daniel J.
    Shepet, Kevin H.
    Kerns, Abigail F.
    Bramer, Michelle A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (05) : E131 - E136
  • [19] The use of three-dimensional navigation and advanced intraoperative imaging in minimally invasive pelvic and acetabular fracture fixation: A systematic review
    Bosakhar, Batool
    Nairn, Leah
    Liu, Kathy
    Chapleau, Julien
    Williams, Dale
    Johal, Herman
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2024, 31 (01) : 60 - 76
  • [20] Does Total Hip Arthroplasty Reduce the Risk of Secondary Surgery Following the Treatment of Displaced Acetabular Fractures in the Elderly Compared to Open Reduction Internal Fixation? A Pilot Study
    Weaver, Michael J.
    Smith, Raymond Malcolm
    Lhowe, David W.
    Vrahas, Mark S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 : S40 - S45