共 29 条
SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
被引:26
作者:
Jung, Joon-Yong
[1
]
Jee, Won-Hee
[1
]
Park, Michael Yong
[1
]
Lee, So-Yeon
[3
]
Kim, Yang-Soo
[2
]
机构:
[1] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Radiol, Seoul 137701, South Korea
[2] Catholic Univ Korea, Coll Med, Seoul St Marys Hosp, Dept Orthopaed Surg, Seoul 137701, South Korea
[3] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Radiol, Seoul, South Korea
关键词:
Shoulder imaging;
MR arthrography;
Three-dimensional;
SPACE;
Superior labral anterior-to-posterior (SLAP) lesions;
SUPERIOR LABRUM ANTERIOR;
GLENOID LABRUM;
3.0;
T;
BICEPS TENDON;
LESIONS;
PERFORMANCE;
POSTERIOR;
KNEE;
DISSECTION;
EXPERIENCE;
D O I:
10.1007/s00330-012-2599-7
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar's test, and inter-observer agreement was calculated using Cohen's kappa. Receiver operating characteristic (ROC) curve analyses were performed. The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE (kappa = 0.76) and 3D TSE-SPACE (kappa = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions aEuro cent MR arthrography is regarded as the definitive method of shoulder imaging aEuro cent Different MR sequences are evolving for SLAP lesions aEuro cent 3D TSE-SPACE demonstrated comparable overall accuracy to 2D TSE for SLAP lesions aEuro cent But more false-negative interpretations occurred using 3D TSE-SPACE aEuro cent Further technical improvement is necessary before 3D TSE-SPACE replaces 2D TSE sequences.
引用
收藏
页码:487 / 495
页数:9
相关论文