Hand-held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review

被引:556
作者
Stark, Timothy [1 ]
Walker, Bruce [1 ]
Phillips, Jacqueline K. [2 ]
Fejer, Rene [3 ]
Beck, Randy [1 ]
机构
[1] Murdoch Univ, Sch Chiropract & Sports Sci, Fac Hlth Sci, Perth, WA 6150, Australia
[2] Macquarie Univ, Australian Sch Adv Med, Sydney, NSW 2109, Australia
[3] Univ So Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
关键词
QUADRICEPS MUSCLE PERFORMANCE; STRENGTH MEASUREMENT; RELIABILITY; VALIDITY; INDIVIDUALS; ADULTS; SCALE;
D O I
10.1016/j.pmrj.2010.10.025
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To examine the current evidence regarding the reliability and validity of hand-held dynamometry for assessment of muscle strength in the clinical setting. Data Sources: A search was conducted of the following databases: Cochrane, MEDLINE, PubMed, PEDro, OTseeker, Index to Chiropractic Literature (ICL), and MANTIS, from inception until January 29, 2010. Study Selection: The MeSH subject heading "muscle strength dynamometer" was searched, in isolation and in combination with the text word phrases "hand-held dynamometer" and "isokinetic." Four hundred fifty-four different studies met this search and were reviewed for possible inclusion. Data Extraction: Two independent reviewers assessed the quality of the included manuscripts. The PEDro data collection system was used in conjunction with the Cochrane Diagnostic Test Accuracy Description. A third reviewer was used when there was disagreement between the primary reviewers. Data Synthesis: Seventeen manuscripts met the inclusion criteria for this review, with a total of 19 studies (2 of the manuscripts involved 2 separate studies) that compared hand-held dynamometry with an identified reference standard (isokinetic muscle strength testing). The results demonstrated minimal differences between hand-held dynamometry and isokinetic testing. Conclusions: Considering hand-held dynamometry's ease of use, portability, cost, and compact size, compared with isokinetic devices this instrument can be regarded as a reliable and valid instrument for muscle strength assessment in a clinical setting. PM R 2011;3:472-479
引用
收藏
页码:472 / 479
页数:8
相关论文
共 47 条
[1]   STRENGTH AND POWER ASSESSMENT - ISSUES, CONTROVERSIES AND CHALLENGES [J].
ABERNETHY, P ;
WILSON, G ;
LOGAN, P .
SPORTS MEDICINE, 1995, 19 (06) :401-417
[2]  
AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
[3]  
[Anonymous], 2008, COCHRANE DATABASE SY
[4]  
[Anonymous], 2005, MUSCLE SENSORY TESTI
[5]   Factors associated with findings of published trials of drug-drug comparisons: Why some statins appear more efficacious than others [J].
Bero, Lisa ;
Oostvogel, Fieke ;
Bacchetti, Peter ;
Lee, Kirby .
PLOS MEDICINE, 2007, 4 (06) :1001-1010
[6]   Hand-held dynamometry: Adoption 1900-2005 [J].
Bohannon, Richard W. .
PERCEPTUAL AND MOTOR SKILLS, 2006, 103 (01) :3-4
[7]   HAND-HELD COMPARED WITH ISOKINETIC DYNAMOMETRY FOR MEASUREMENT OF STATIC KNEE EXTENSION TORQUE (PARALLEL RELIABILITY OF DYNAMOMETERS) [J].
BOHANNON, RW .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03) :217-222
[8]   USE OF A HAND-HELD DYNAMOMETER AND A KIN-COM(R) DYNAMOMETER FOR EVALUATING SPASTIC HYPERTONIA IN CHILDREN - A RELIABILITY STUDY [J].
BOITEAU, M ;
MALOUIN, F ;
RICHARDS, CL .
PHYSICAL THERAPY, 1995, 75 (09) :796-802
[9]  
Brandsma J W, 1995, J Hand Ther, V8, P185
[10]   SHOULDER ABDUCTION STRENGTH MEASUREMENT IN FOOTBALL PLAYERS - RELIABILITY AND VALIDITY OF 2 FIELD-TESTS [J].
BURNHAM, RS ;
BELL, G ;
OLENIK, L ;
REID, DC .
CLINICAL JOURNAL OF SPORT MEDICINE, 1995, 5 (02) :90-94