Velocity-selective arterial spin labeling

被引:188
作者
Wong, Eric C.
Cronin, Matthew
Wu, Wen-Chau
Inglis, Ben
Frank, Lawrence R.
Liu, Thomas T.
机构
[1] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Psychiat, La Jolla, CA 92093 USA
[3] Univ Calif Berkeley, Brain Imaging Ctr, Berkeley, CA 94720 USA
关键词
cerebral blood flow; arterial spin labeling; velocity selective; transit delay; background suppression;
D O I
10.1002/mrm.20906
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In pathologies in which slow or collateral flow conditions may exist, conventional arterial spin labeling (ASL) methods that apply magnetic tags based on the location of arterial spins may not provide robust measures of cerebral blood flow (CBF), as the transit delay for the delivery of blood to target tissues may far exceed the relaxation time of the tag. Here we describe current methods for ASL with velocity-selective (VS) tags (termed VSASL) that do not require spatial selectivity and can thus provide quantitative measures of CBF under slow and collateral flow conditions. The implementation of a robust multislice VSASL technique is described in detail, and data obtained with this technique are compared with those obtained with conventional pulsed ASL (PASL). The technical considerations described here include the design of VS pulses, background suppression, anisotropy with respect to velocity-encoding directions, and CBF quantitation issues.
引用
收藏
页码:1334 / 1341
页数:8
相关论文
共 34 条
  • [1] Multisection cerebral blood flow MR imaging with continuous arterial spin labeling
    Alsop, DC
    Detre, JA
    [J]. RADIOLOGY, 1998, 208 (02) : 410 - 416
  • [2] Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    Alsop, DC
    Detre, JA
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) : 1236 - 1249
  • [3] A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    Buxton, RB
    Frank, LR
    Wong, EC
    Siewert, B
    Warach, S
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 383 - 396
  • [4] VARIABLE-RATE SELECTIVE EXCITATION
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    GLOVER, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 440 - 458
  • [5] A REDUCED POWER SELECTIVE ADIABATIC SPIN-ECHO PULSE SEQUENCE
    CONOLLY, S
    GLOVER, G
    NISHIMURA, D
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 28 - 38
  • [6] Velocity-selective RF pulses in MRI
    de Rochefort, L
    Maître, X
    Bittoun, J
    Durand, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) : 171 - 176
  • [7] TISSUE-SPECIFIC PERFUSION IMAGING USING ARTERIAL SPIN-LABELING
    DETRE, JA
    ZHANG, WG
    ROBERTS, DA
    SILVA, AC
    WILLIAMS, DS
    GRANDIS, DJ
    KORETSKY, AP
    LEIGH, JS
    [J]. NMR IN BIOMEDICINE, 1994, 7 (1-2) : 75 - 82
  • [8] Evaluation of systematic quantification errors in velocity-selective arterial spin labeling of the brain
    Duhamel, G
    de Bazelaire, U
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 145 - 153
  • [9] EPISTAR MRI: Multislice mapping of cerebral blood flow
    Edelman, RR
    Chen, G
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) : 800 - 805
  • [10] Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories
    Floyd, TF
    Ratcliffe, SJ
    Wang, JJ
    Resch, B
    Detre, JA
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) : 649 - 655