Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

被引:44
作者
Niesten, Joris M. [1 ]
van der Schaaf, Irene C. [1 ]
Riordan, Alan J. [1 ]
de Jong, Hugo W. A. M. [1 ]
Horsch, Alexander D. [2 ]
Eijspaart, Daniel [1 ]
Smit, Ewoud J. [1 ]
Mali, Willem P. T. M. [1 ]
Velthuis, Birgitta K. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
关键词
Cerebral perfusion; Stroke; Infarction; Computed tomography; Radiation dose; TEMPORAL RESOLUTION; ISCHEMIC-STROKE; PARAMETERS; ALGORITHMS; ACCURACY; QUALITY; VOLUME; NOISE;
D O I
10.1007/s00330-013-3042-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate whether iterative reconstruction (IR) in cerebral CT perfusion (CTP) allows for 50 % dose reduction while maintaining image quality (IQ). A total of 48 CTP examinations were reconstructed into a standard dose (150 mAs) with filtered back projection (FBP) and half-dose (75 mAs) with two strengths of IR (middle and high). Objective IQ (quantitative perfusion values, contrast-to-noise ratio (CNR), penumbra, infarct area and penumbra/infarct (P/I) index) and subjective IQ (diagnostic IQ on a four-point Likert scale and overall IQ binomial) were compared among the reconstructions. Half-dose CTP with high IR level had, compared with standard dose with FBP, similar objective (grey matter cerebral blood volume (CBV) 4.4 versus 4.3 mL/100 g, CNR 1.59 versus 1.64 and P/I index 0.74 versus 0.73, respectively) and subjective diagnostic IQ (mean Likert scale 1.42 versus 1.49, respectively). The overall IQ in half-dose with high IR level was scored lower in 26-31 %. Half-dose with FBP and with the middle IR level were inferior to standard dose with FBP. With the use of IR in CTP imaging it is possible to examine patients with a half dose without significantly altering the objective and diagnostic IQ. The standard dose with FBP is still preferable in terms of subjective overall IQ in about one quarter of patients. Key points Computed tomography perfusion (CTP) is increasingly important in ischaemia imaging. Radiation exposure of CTP is a drawback. Iterative reconstruction (IR) allows reduction of radiation dose in unenhanced head CT. CTP IR enables 50 % dose reduction without altering objective and diagnostic quality.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 50 条
[41]   Accurate tissue characterization in low-dose CT imaging with pure iterative reconstruction [J].
Murphy, Kevin P. ;
McLaughlin, Patrick D. ;
Twomey, Maria ;
Chan, Vincent E. ;
Moloney, Fiachra ;
Fung, Adrian J. ;
Chan, Faimee E. ;
Kao, Tafline ;
O'Neill, Siobhan B. ;
Watson, Benjamin ;
O'Connor, Owen J. ;
Maher, Michael M. .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (02) :190-196
[42]   Iterative reconstruction for image enhancement and dose reduction in diagnostic cone beam CT imaging [J].
Matenine, Dmitri ;
Schmittbuhl, Matthieu ;
Bedwani, Stephane ;
Despres, Philippe ;
de Guise, Jacques A. .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (05) :805-819
[43]   Can Iterative Reconstruction Improve Imaging Quality for Lower Radiation CT Perfusion? Initial Experience [J].
Lin, C. J. ;
Wu, T. H. ;
Lin, C. H. ;
Hung, S. C. ;
Chiu, C. F. ;
Liu, M. -J. ;
Teng, M. M. H. ;
Chang, F. C. ;
Guo, W. Y. ;
Chang, C. Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (08) :1516-1521
[44]   Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :655-660
[45]   Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study [J].
den Harder, Annemarie M. ;
Willemink, Martin J. ;
van Doormaal, Pieter J. ;
Wessels, Frank J. ;
Lock, M. T. W. T. ;
Schilham, Arnold M. R. ;
Budde, Ricardo P. J. ;
Leiner, Tim ;
de Jong, Pim A. .
EUROPEAN RADIOLOGY, 2018, 28 (01) :143-150
[46]   Radiation Dose Reduction Opportunities in Vascular Imaging [J].
Summerlin, David ;
Willis, Joseph ;
Boggs, Robert ;
Johnson, Loretta M. ;
Porter, Kristin K. .
TOMOGRAPHY, 2022, 8 (05) :2618-2638
[47]   Reducing CT radiation dose with iterative reconstruction algorithms: The influence of scan and reconstruction parameters on image quality and CTDIvol [J].
Klink, Thorsten ;
Obmann, Verena ;
Heverhagen, Johannes ;
Stork, Alexander ;
Adam, Gerhard ;
Begemann, Philipp .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) :1645-1654
[48]   Patient radiation dose reduction using a commercial iterative reconstruction technique package [J].
Sulieman, A. ;
Adam, H. ;
Elnour, A. ;
Tamam, N. ;
Alhaili, A. ;
Alkhorayef, M. ;
Alghamdi, S. ;
Khandaker, Mayeen Uddin ;
Bradley, D. A. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 178
[49]   Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction [J].
Fahimian, Benjamin P. ;
Zhao, Yunzhe ;
Huang, Zhifeng ;
Fung, Russell ;
Mao, Yu ;
Zhu, Chun ;
Khatonabadi, Maryam ;
DeMarco, John J. ;
Osher, Stanley J. ;
McNitt-Gray, Michael F. ;
Miao, Jianwei .
MEDICAL PHYSICS, 2013, 40 (03)
[50]   The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations [J].
Harun, H. H. ;
Karim, M. K. A. ;
Abbas, Z. ;
Sabarudin, A. ;
Muniandy, S. C. ;
Razak, H. R. A. ;
Ng, K. H. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 178