Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

被引:39
作者
Niesten, Joris M. [1 ]
van der Schaaf, Irene C. [1 ]
Riordan, Alan J. [1 ]
de Jong, Hugo W. A. M. [1 ]
Horsch, Alexander D. [2 ]
Eijspaart, Daniel [1 ]
Smit, Ewoud J. [1 ]
Mali, Willem P. T. M. [1 ]
Velthuis, Birgitta K. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
关键词
Cerebral perfusion; Stroke; Infarction; Computed tomography; Radiation dose; TEMPORAL RESOLUTION; ISCHEMIC-STROKE; PARAMETERS; ALGORITHMS; ACCURACY; QUALITY; VOLUME; NOISE;
D O I
10.1007/s00330-013-3042-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate whether iterative reconstruction (IR) in cerebral CT perfusion (CTP) allows for 50 % dose reduction while maintaining image quality (IQ). A total of 48 CTP examinations were reconstructed into a standard dose (150 mAs) with filtered back projection (FBP) and half-dose (75 mAs) with two strengths of IR (middle and high). Objective IQ (quantitative perfusion values, contrast-to-noise ratio (CNR), penumbra, infarct area and penumbra/infarct (P/I) index) and subjective IQ (diagnostic IQ on a four-point Likert scale and overall IQ binomial) were compared among the reconstructions. Half-dose CTP with high IR level had, compared with standard dose with FBP, similar objective (grey matter cerebral blood volume (CBV) 4.4 versus 4.3 mL/100 g, CNR 1.59 versus 1.64 and P/I index 0.74 versus 0.73, respectively) and subjective diagnostic IQ (mean Likert scale 1.42 versus 1.49, respectively). The overall IQ in half-dose with high IR level was scored lower in 26-31 %. Half-dose with FBP and with the middle IR level were inferior to standard dose with FBP. With the use of IR in CTP imaging it is possible to examine patients with a half dose without significantly altering the objective and diagnostic IQ. The standard dose with FBP is still preferable in terms of subjective overall IQ in about one quarter of patients. Key points Computed tomography perfusion (CTP) is increasingly important in ischaemia imaging. Radiation exposure of CTP is a drawback. Iterative reconstruction (IR) allows reduction of radiation dose in unenhanced head CT. CTP IR enables 50 % dose reduction without altering objective and diagnostic quality.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 50 条
  • [21] Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method
    Yu, Lifeng
    Fletcher, Joel G.
    Shiung, Maria
    Thomas, Kristen B.
    Matsumoto, Jane M.
    Zingula, Shannon N.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1026 - 1037
  • [22] CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose
    Jay E. Haggerty
    Ethan A. Smith
    Shaun M. Kunisaki
    Jonathan R. Dillman
    Pediatric Radiology, 2015, 45 : 989 - 997
  • [23] Reducing Abdominal CT Radiation Dose With Adaptive Statistical Iterative Reconstruction Technique
    Prakash, Priyanka
    Kalra, Mannudeep K.
    Kambadakone, Avinash K.
    Pien, Homer
    Hsieh, Jiang
    Blake, Michael A.
    Sahani, Dushyant V.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (04) : 202 - 210
  • [24] Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction
    Eck, Brendan L.
    Fahmi, Rachid
    Fuqua, Christopher
    Vembar, Mani
    Dhanantwari, Amar
    Bezerra, Hiram G.
    Wilson, David L.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [25] Radiation dose reduction in soft tissue neck CT using adaptive statistical iterative reconstruction (ASIR)
    Vachha, Behroze
    Brodoefel, Harald
    Wilcox, Carol
    Hackney, David B.
    Moonis, Gul
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2222 - 2226
  • [26] Possibilities of dose reduction during CT imaging by application of iterative image reconstruction
    Bajzik Gabor
    Toth Anetti
    Donko Tamas
    Kovacs Peter
    Sipos David
    Pandur Attila Andras
    Moizs Mariann
    Hadjiev Janaki
    Repa Imre
    Kovacs Arpad
    ORVOSI HETILAP, 2019, 160 (35) : 1387 - 1394
  • [27] An Efficient Iterative Cerebral Perfusion CT Reconstruction via Low-Rank Tensor Decomposition With Spatial-Temporal Total Variation Regularization
    Li, Sui
    Zeng, Dong
    Peng, Jiangjun
    Bian, Zhaoying
    Zhang, Hao
    Xie, Qi
    Wang, Yongbo
    Liao, Yuting
    Zhang, Shanli
    Huang, Jing
    Meng, Deyu
    Xu, Zongben
    Ma, Jianhua
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (02) : 360 - 370
  • [28] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [29] Ultra-Low-Dose CT of the Thorax Using Iterative Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
    Kim, Yookyung
    Kim, Yoon Kyung
    Lee, Bo Eun
    Lee, Seok Jeong
    Ryu, Yon Ju
    Lee, Jin Hwa
    Chang, Jung Hyun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) : 1197 - 1202
  • [30] Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT
    Sohi Bae
    Myung-Joon Kim
    Choon-Sik Yoon
    Dong Wook Kim
    Jung Hwa Hong
    Mi-Jung Lee
    Pediatric Radiology, 2014, 44 : 1541 - 1547