Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

被引:39
|
作者
Niesten, Joris M. [1 ]
van der Schaaf, Irene C. [1 ]
Riordan, Alan J. [1 ]
de Jong, Hugo W. A. M. [1 ]
Horsch, Alexander D. [2 ]
Eijspaart, Daniel [1 ]
Smit, Ewoud J. [1 ]
Mali, Willem P. T. M. [1 ]
Velthuis, Birgitta K. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
关键词
Cerebral perfusion; Stroke; Infarction; Computed tomography; Radiation dose; TEMPORAL RESOLUTION; ISCHEMIC-STROKE; PARAMETERS; ALGORITHMS; ACCURACY; QUALITY; VOLUME; NOISE;
D O I
10.1007/s00330-013-3042-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate whether iterative reconstruction (IR) in cerebral CT perfusion (CTP) allows for 50 % dose reduction while maintaining image quality (IQ). A total of 48 CTP examinations were reconstructed into a standard dose (150 mAs) with filtered back projection (FBP) and half-dose (75 mAs) with two strengths of IR (middle and high). Objective IQ (quantitative perfusion values, contrast-to-noise ratio (CNR), penumbra, infarct area and penumbra/infarct (P/I) index) and subjective IQ (diagnostic IQ on a four-point Likert scale and overall IQ binomial) were compared among the reconstructions. Half-dose CTP with high IR level had, compared with standard dose with FBP, similar objective (grey matter cerebral blood volume (CBV) 4.4 versus 4.3 mL/100 g, CNR 1.59 versus 1.64 and P/I index 0.74 versus 0.73, respectively) and subjective diagnostic IQ (mean Likert scale 1.42 versus 1.49, respectively). The overall IQ in half-dose with high IR level was scored lower in 26-31 %. Half-dose with FBP and with the middle IR level were inferior to standard dose with FBP. With the use of IR in CTP imaging it is possible to examine patients with a half dose without significantly altering the objective and diagnostic IQ. The standard dose with FBP is still preferable in terms of subjective overall IQ in about one quarter of patients. Key points Computed tomography perfusion (CTP) is increasingly important in ischaemia imaging. Radiation exposure of CTP is a drawback. Iterative reconstruction (IR) allows reduction of radiation dose in unenhanced head CT. CTP IR enables 50 % dose reduction without altering objective and diagnostic quality.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 50 条
  • [1] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [2] Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature
    Othman, Ahmed E.
    Afat, Saif
    Brockmann, Marc A.
    Nikoubashman, Omid
    Brockmann, Carolin
    Nikolaou, Konstantin
    Wiesmann, Martin
    JOURNAL OF NEURORADIOLOGY, 2016, 43 (01) : 1 - 5
  • [3] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Othman, Ahmed E.
    Brockmann, Carolin
    Yang, Zepa
    Kim, Changwon
    Afat, Saif
    Pjontek, Rastislav
    Nikobashman, Omid
    Brockmann, Marc A.
    Kim, Jong Hyo
    Wiesmann, Martin
    EUROPEAN RADIOLOGY, 2015, 25 (12) : 3415 - 3422
  • [4] Reduction in radiation dose with reconstruction technique in the brain perfusion CT
    Kim, H. J.
    Lee, H. K.
    Song, H.
    Ju, M. S.
    Dong, K. R.
    Chung, W. K.
    Cho, M. S.
    Cho, J. H.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (12): : 918 - 926
  • [5] Radiation dose reduction in perfusion CT imaging of the brain using a 256-slice CT: 80 mAs versus 160 mAs
    Riederer, Isabelle
    Zimmer, Claus
    Pfeiffer, Daniela
    Wunderlich, Silke
    Poppert, Holger
    Rummeny, Ernst J.
    Huber, Armin
    CLINICAL IMAGING, 2018, 50 : 188 - 193
  • [6] Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network
    Moghari, Mahdieh Dashtbani
    Sanaat, Amirhossein
    Young, Noel
    Moore, Krystal
    Zaidi, Habib
    Evans, Andrew
    Fulton, Roger R.
    Kyme, Andre Z.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (16)
  • [7] Radiation Dose Reduction in CT Myocardial Perfusion Imaging Using SMART-RECON
    Li, Yinsheng
    Speidel, Michael A.
    Francois, Christopher J.
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (12) : 2557 - 2568
  • [8] Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms
    Othman, A. E.
    Afat, S.
    Brockmann, C.
    Nikoubashman, O.
    Bier, G.
    Brockmann, M. A.
    Nikolaou, K.
    Tai, J. H.
    Yang, Z. P.
    Kim, J. H.
    Wiesmann, M.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 311 - 318
  • [9] Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom study
    Dodge, Cristina T.
    Tamm, Eric P.
    Cody, Dianna D.
    Liu, Xinming
    Jensen, Corey T.
    Wei, Wei
    Kundra, Vikas
    Rong, X. John
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 511 - 531
  • [10] Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique
    Bang, Minseo
    Choi, Seong Hoon
    Park, Jongha
    Kang, Byeong Seong
    Kwon, Woon Jung
    Lee, Tae Hoon
    Nam, Jung Gwon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 982 - 987