Shear bond strength of self-etching adhesive systems to Er:YAG-laser-prepared dentin

被引:26
作者
Brulat, Nathalie [2 ]
Rocca, Jean-Paul [2 ]
Leforestier, Eric [2 ]
Fiorucci, Gilbert [3 ]
Nammour, Samir [4 ]
Bertrand, Marie-France [1 ,2 ]
机构
[1] UFR Odontol, F-06537 Nice 4, France
[2] Univ Nice Sophia Antipolis, Lab Surfaces & Interfaces Odontol, Nice, France
[3] ENSMP, Ctr Mat Forming, Sophia Antipolis, France
[4] Univ Liege, Fac Med, Dept Dent Sci, Liege, Belgium
关键词
Dentin; Er:YAG laser; Self-etching adhesive systems; Shear bond strength; ER-YAG-LASER;
D O I
10.1007/s10103-007-0519-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study was conducted to compare the shear bond strengths of composite resin bonded to Er:YAG laser or bur-prepared dentin surfaces using three self-etching adhesive systems. The occlusal surfaces of 120 human third molars were ground flat to expose dentin. The dentin was prepared using either a carbide bur or an Er:YAG laser at 350 mJ/pulse and 10 Hz (fluence, 44.5 J/cm(2)). Three different self-etching adhesive systems were applied: iBond (TM), Xeno III (TM) and Clearfil SE Bond (TM). Rods of composite resin were bonded to dentin surfaces and shear bond tests were carried out. Both dentin surfaces after debonding and resin rods were observed using a scanning electron microscope. When the Xeno III (TM) was used, no difference was observed on shear bond strength values when bur and Er:YAG laser were compared. When using iBond (TM) and Clearfil SE Bond (TM), bond strength values measured on Er:YAG-laser-prepared surfaces were lower than those observed on bur-prepared surfaces. The absence of smear layer formation during the preparation of the dentin by the Er:YAG laser did not improve the adhesion values of self-etching adhesive systems.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 17 条
[1]   Scanning electron microscopic analysis of diseased and healthy dental hard tissues after Er:YAG laser irradiation:: In vitro study [J].
Armengol, V ;
Jean, A ;
Rohanizadeh, R ;
Hamel, H .
JOURNAL OF ENDODONTICS, 1999, 25 (08) :543-546
[2]  
Arrais Cesar Augusto Galvao, 2002, Pesqui Odontol Bras, V16, P115
[3]   Scanning electron microscopic evaluation of resin-dentin interface after Er:YAG laser preparation [J].
Bertrand, MF ;
Hessleyer, D ;
Muller-Bolla, M ;
Nammour, S ;
Rocca, JP .
LASERS IN SURGERY AND MEDICINE, 2004, 35 (01) :51-57
[4]   THE INFLUENCE OF AGE AND DEPTH OF DENTIN ON BONDING [J].
BURROW, MF ;
TAKAKURA, H ;
NAKAJIMA, R ;
INAI, N ;
TAGAMI, J ;
TAKATSU, T .
DENTAL MATERIALS, 1994, 10 (04) :241-246
[5]   Bonding to Er-YAG-laser-treated dentin [J].
Ceballos, L ;
Toledano, M ;
Osorio, R ;
Tay, FR ;
Marshall, GW .
JOURNAL OF DENTAL RESEARCH, 2002, 81 (02) :119-122
[6]   Morpho-structural aspects of Er:YAG-prepared class V cavities [J].
Curti, M ;
Rocca, JP ;
Bertrand, MF ;
Nammour, S .
JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2004, 22 (02) :119-123
[7]  
Dostalova Tatjana, 1996, Scanning Microscopy, V10, P285
[8]   Adhesion of Er:YAG laser-irradiated dentin and composite resins:: Application of various treatments on irradiated surface [J].
Eguro, T ;
Maeda, T ;
Otsuki, M ;
Nishimura, Y ;
Katsuumi, I ;
Tanaka, H .
LASERS IN SURGERY AND MEDICINE, 2002, 30 (04) :267-272
[9]  
Hoke J A, 1990, J Laser Appl, V2, P61, DOI 10.2351/1.4745270
[10]   Bond strength of self-etching adhesives to dental hard tissues [J].
Kaaden C. ;
Powers J.M. ;
Friedl K.H. ;
Schmalz G. .
Clinical Oral Investigations, 2002, 6 (3) :155-160