Development of an Indoor Environmental Quality Assessment Tool for the Rating of Offices in Real Working Conditions

被引:13
作者
Devitofrancesco, Anna [1 ]
Belussi, Lorenzo [1 ]
Meroni, Italo [1 ]
Scamoni, Fabio [1 ]
机构
[1] Natl Res Council Italy ITC CNR, Construct Technol Inst, Via Lombardia 49, I-20098 Milan, Italy
关键词
indoor environmental quality; SB method; multi criteria analysis; monitoring and measurement; office building; real working conditions; FACADE SOUND INSULATION; SUSTAINABILITY ASSESSMENT; ENERGY-CONSUMPTION; THERMAL COMFORT; BUILDINGS; CLASSIFICATION; POSTOCCUPANCY; PERFORMANCE; FRAMEWORK; WORLDWIDE;
D O I
10.3390/su11061645
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Indoor Environmental Quality (IEQ) refers to the quality of indoor spaces in relation to the health and well-being of users. IEQ is a holistic concept considering various components of the overall indoor comfort: thermo-hygrometric, lighting, air quality and acoustics. Each component is described through specific performance indicators and benchmarks. The quality of the built environment is assessed at different stages from design to operational phase. The scientific literature reports several case studies related to the assessment of the individual components of the IEQ Tools aimed at the evaluation of the overall IEQ. The paper proposes an assessment tool based on the SB Method (Sustainable Building Method) and the Multi Criteria Analysis for the evaluation of IEQ during the operational phase of a building. Each component of IEQ is analysed through objective indicators and calculation methods. The tool provides two main outcomes: a global score expressing the overall performance of the building from the IEQ perspective; quantitative evaluations of all indoor comfort components through monitoring and measurement of the environmental variables. The above contributes to select intervention areas to optimize indoor design and to identify technologies aimed at ensuring the best IEQ levels for users at the operational stage. The system was applied to an open-plan working space of an office building. Monitoring activities and measurements are carried out to detect the indoor and outdoor variables affecting the IEQ. All aspects of IEQ were analysed and quantified so to evaluate the overall performance of the building and provide data to improve the working conditions.
引用
收藏
页数:17
相关论文
共 45 条
[41]   Integration of a do it yourself hardware in a lighting device for the management of thermal comfort and energy use [J].
Salamone, Francesco ;
Belussi, Lorenzo ;
Danza, Ludovico ;
Ghellere, Matteo ;
Meroni, Italo .
71ST CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION (ATI 2016), 2016, 101 :161-168
[42]   Effect of outdoor noise and facade sound insulation on indoor acoustic environment of Italian schools [J].
Secchi, Simone ;
Astolfi, Arianna ;
Calosso, Giulia ;
Casini, David ;
Cellai, Gianfranco ;
Scamoni, Fabio ;
Scrosati, Chiara ;
Shtrepi, Louena .
APPLIED ACOUSTICS, 2017, 126 :120-130
[43]   A comparative analysis of building environmental assessment tools and suggestions for regional adaptations [J].
Sev, Aysin .
CIVIL ENGINEERING AND ENVIRONMENTAL SYSTEMS, 2011, 28 (03) :231-245
[44]   Developing post occupancy evaluation sustainability assessment framework for retrofitting commercial office buildings: A proposal [J].
Shika, Suleiman Aliyu ;
Sapri, Maimunah ;
Jibril, Jibril Dan'azimi ;
Sipan, Ibrahim ;
Abdullah, Shahabudin .
INTERNATIONAL CONGRESS ON INTERDISCIPLINARY BUSINESS AND SOCIAL SCIENCES 2012 (ICIBSOS 2012), 2012, 65 :644-649
[45]   Indoor environmental quality of classrooms and occupants' comfort in a special education school in Slovak Republic [J].
Vilcekova, Silvia ;
Meciarova, Ludmila ;
Burdova, Eva Kridlova ;
Katunska, Jana ;
Kosicanova, Danica ;
Doroudiani, Saeed .
BUILDING AND ENVIRONMENT, 2017, 120 :29-40