Transmission Mode Desorption Electrospray Ionization (TM-DESI) for Simultaneous Analysis of Potential Inorganic and Organic Components of Radiological Dispersion Devices (RDDs)

被引:19
作者
Evans-Nguyen, Kenyon M. [1 ]
Quinto, Amanda [1 ]
Hargraves, Tiffanie [1 ]
Brown, Hilary [1 ]
Speer, Jennifer [1 ]
Glatter, David [1 ]
机构
[1] Univ Tampa, Dept Chem Biochem & Phys, Tampa, FL 33606 USA
关键词
RESOLUTION MASS-SPECTROMETRY; ELEMENTAL ANALYSIS; GUNSHOT RESIDUE; METAL-IONS; GAS-PHASE; CHEMISTRY; M2+;
D O I
10.1021/ac402386m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Transmission mode desorption electrospray ionization (TM-DESI) coupled to an ion trap mass spectrometer capable of source collision-induced dissociation (CID) was used to completely analyze radiological dispersion device components. Source CID significantly enhanced the signal for metal ions by reducing adducts while eliminating chemical noise from background molecules through extensive fragmentation. Source CID spectra yielded reasonably accurate isotopic ratios for the metals studied. By switching the source CID on and off between scans, all major constituents in mixtures of simulated radionuclides and explosives were simultaneously observed. These results indicate that TM-DESI/ion trap technology could be a powerful on-site tool for nuclear forensics.
引用
收藏
页码:11826 / 11834
页数:9
相关论文
共 28 条