Are Locking Screws Advantageous with Plate Fixation of Humeral Shaft Fractures? A Biomechanical Analysis of Synthetic and Cadaveric Bone

被引:62
作者
O'Toole, Robert V. [1 ]
Andersen, Romney C. [1 ,2 ]
Vesnovsky, Oleg [3 ]
Alexander, Melvin [4 ]
Topoleski, L. D. Timmie [3 ]
Nascone, Jason W. [1 ]
Sciadini, Marcus F. [1 ]
Turen, Clifford [1 ]
Eglseder, W. Andrew, Jr. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Orthopaed, R Adams Cowley Shock Trauma Ctr, Baltimore, MD 21201 USA
[2] Walter Reed Natl Mil Med Ctr, Washington, DC USA
[3] Univ Maryland Baltimore Cty, Dept Engn Mech, Baltimore, MD 21201 USA
[4] Univ Maryland, Med Ctr, Natl Study Ctr Trauma & Emergency Med Syst, Baltimore, MD 21201 USA
关键词
humeral shaft fractures; locking screws; plate fixation; axial loading; biomechanics;
D O I
10.1097/BOT.0b013e31818df8cb
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To investigate whether locking screws offer any advantage over nonlocking screws for plate fixation of humeral shaft fractures for weight-bearing applications. Design: Mechanical evaluation of stiffness in torsion, bending, and axial loading and failure in axial loading in synthetic and cadaveric bone. Setting: Biomechanical laboratory in an academic medical center. Methods: We modeled a comminuted midshaft humeral fracture in both synthetic and cadaveric bone. Humeri were plated posteriorly. Two study groups each used identical 10-hole, 3.5-mm locking compression plates that can accept either locking or nonlocking screws. The first group used only nonlocking screws and the second only locking screws. Stiffness testing and failure testing were performed for both the synthetic bones (n = 6) and the cadaveric matched pairs (n = 12). Fatigue testing was set at 90,000 cycles of 440 N of axial loading. Main Outcome Measures: Torsion, bending, and axial stiffness and axial failure force after cyclic loading. Results: With synthetic bones, no significant difference was observed in any of the 4 tested stiffness modes between the plates with locking screws and those with nonlocking screws (anteroposterior, P = 0.51; mediolateral, P = 0.50; axial, P = 0.15; torsional, P = 0.08). With initial failure testing of the constructs in axial loading, both plates failed above anticipated physiologic loads of 440 N (mean failure load for both constructs >4200 N), but no advantage to locking screws was shown. The cadaveric portion of the study also showed no biomechanical advantage of locking screws over nonlocking screws for stiffness of the construct in the 4 tested modes (P > 0.40). Fatigue and failure testing showed that both constructs were able to withstand strenuous fatigue and to fail above anticipated loads (mean failure >3400 N). No difference in failure force was shown between the 2 groups (P = 0.67). Conclusions: Synthetic and cadaveric bone testing showed that locking screws offer no obvious biomechanical benefit in this application.
引用
收藏
页码:709 / 715
页数:7
相关论文
共 58 条
  • [21] Gardner Michael J, 2005, J Orthop Trauma, V19, P597, DOI 10.1097/01.bot.0000174033.30054.5f
  • [22] Hybrid locked plating of osteoporotic fractures of the humerus
    Gardner, Michael J.
    Griffith, Matthew H.
    Demetrakopoulos, Demetris
    Brophy, Robert H.
    Grose, Andrew
    Helfet, David L.
    Lorich, Dean G.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (09) : 1962 - 1967
  • [23] Gardner Michael J, 2004, Am J Orthop (Belle Mead NJ), V33, P439
  • [24] Innovations in locking plate technology
    Haidukewych, GJ
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2004, 12 (04) : 205 - 212
  • [25] Henley M B, 1991, J Orthop Trauma, V5, P14, DOI 10.1097/00005131-199103000-00003
  • [26] Use of a locking reconstruction bone plate/screw system for mandibular surgery
    Herford, AS
    Ellis, E
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (11) : 1261 - 1265
  • [27] Distal femoral fixation: A biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate
    Koval, KJ
    Hoehl, JJ
    Kummer, FJ
    Simon, JA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (07) : 521 - 524
  • [28] Treatment of distal femur fractures using the Less Invasive Stabilization System - Surgical experience and early clinical results in 103 fractures
    Kregor, PJ
    Stannard, JA
    Zlowodzki, M
    Cole, PA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 509 - 520
  • [29] The evolution of locked plates
    Kubiak, Erik N.
    Fulkerson, Eric
    Strauss, Eric
    Egol, Kfdineth A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 189 - 200
  • [30] A prospective, randomized trial comparing the limited contact dynamic compression plate with the Point Contact Fixator for forearm fractures
    Leung, F
    Chow, SP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) : 2343 - 2348