Absorbed dose model to scan parameters in dental cone beam computed tomography

被引:0
作者
Jia, Shumei [1 ]
Guo, Xiaoyue [1 ]
Xing, Yuxiang [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
来源
2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2019年
关键词
CT;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cone beam computed tomography (CBCT) is widely applied in dental and maxillofacial diagnostic imaging, which raises great concerns to radiological dose caused by this device. This work measures the absorbed dose inside an uniform cylindrical phantom when it is scanned by dental CBCT at different scan parameters of mAs and kV; meanwhile, studies the relationship of absorbed dose to scan parameters. The result indicates that absorbed dose is correlated to scan parameters in an empirical model form of D = (a center dot HVL2 + b) center dot mAs with coefficient of determination above 0.99. This empirical model can be applied to other type dental CBCT devices to provide as an estimation method of radiology dose at different scan parameter settings. Moreover, absorbed dose is proportional to field of view size and inversely proportional to phantom size.
引用
收藏
页数:4
相关论文
共 50 条
[41]   Measurement of skin dose from cone-beam computed tomography imaging [J].
Akyalcin, Sercan ;
English, Jeryl D. ;
Abramovitch, Kenneth M. ;
Rong, Xiujiang J. .
HEAD & FACE MEDICINE, 2013, 9
[42]   Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography [J].
Chau, Anson C. M. ;
Fung, Karl .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04) :559-565
[43]   Optimising the parameters of cochlear implant imaging with cone-beam computed tomography [J].
Soederqvist, Samuel ;
Sivonen, Ville ;
Aarnisalo, Antti ;
Karppi, Harri ;
Sinkkonen, Saku T. ;
Koivisto, Juha .
RADIATION PROTECTION DOSIMETRY, 2023, 199 (05) :462-470
[44]   A New Method for Cone-Beam Computed Tomography Geometric Parameters Estimation [J].
Zhou, Kun ;
Huang, Yixing ;
Meng, Xiangxi ;
Li, Zhen ;
Li, Suying ;
Yang, Kun ;
Ren, Qiushi .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (04) :639-648
[45]   The impact of different dental restorations on detection of proximal caries by cone beam computed tomography [J].
Abu El-Ela, Walaa Hussein ;
Farid, Mary Medhat ;
Abou El-Fotouh, Mona .
CLINICAL ORAL INVESTIGATIONS, 2022, 26 (03) :2413-2420
[46]   Establishment of diagnostic reference levels for dental cone beam computed tomography in Tabriz, Iran [J].
Mardfar, Sina ;
Ghaziyani, Mona Fazel ;
Vahdat, Arman Saeedi ;
Khezerloo, Davood .
RADIATION PROTECTION DOSIMETRY, 2025, 201 (09) :641-647
[47]   In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography [J].
Benic, Goran I. ;
Sancho-Puchades, Manuel ;
Jung, Ronald E. ;
Deyhle, Hans ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) :378-383
[48]   Automatic Synthesis of Panoramic Radiographs from Dental Cone Beam Computed Tomography Data [J].
Luo, Ting ;
Shi, Changrong ;
Zhao, Xing ;
Zhao, Yunsong ;
Xu, Jinqiu .
PLOS ONE, 2016, 11 (06)
[49]   DOSIMETRIC EVALUATION OF DENTAL IMPLANT PLANNING EXAMINATIONS WITH CONE-BEAM COMPUTED TOMOGRAPHY [J].
Andrade, Marcos E. A. ;
Khoury, Helen J. ;
Nascimento Neto, Joao B. S. ;
Kramer, Richard .
RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) :175-180
[50]   An Overview of Cone-Beam Computed Tomography and Dental Panoramic Radiography in Dentistry in the Community [J].
MacDonald, David ;
Telyakova, Vera .
TOMOGRAPHY, 2024, 10 (08) :1222-1237