Absorbed dose model to scan parameters in dental cone beam computed tomography

被引:0
作者
Jia, Shumei [1 ]
Guo, Xiaoyue [1 ]
Xing, Yuxiang [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
来源
2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2019年
关键词
CT;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cone beam computed tomography (CBCT) is widely applied in dental and maxillofacial diagnostic imaging, which raises great concerns to radiological dose caused by this device. This work measures the absorbed dose inside an uniform cylindrical phantom when it is scanned by dental CBCT at different scan parameters of mAs and kV; meanwhile, studies the relationship of absorbed dose to scan parameters. The result indicates that absorbed dose is correlated to scan parameters in an empirical model form of D = (a center dot HVL2 + b) center dot mAs with coefficient of determination above 0.99. This empirical model can be applied to other type dental CBCT devices to provide as an estimation method of radiology dose at different scan parameter settings. Moreover, absorbed dose is proportional to field of view size and inversely proportional to phantom size.
引用
收藏
页数:4
相关论文
共 50 条
[31]   In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT) [J].
Fisekcioglu, Erdogan ;
Dolekoglu, Semanur ;
Ilguy, Mehmet ;
Ersan, Nilufer ;
Ilguy, Dilhan .
IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (01)
[32]   Detection of dental root fractures by using cone-beam computed tomography [J].
Wang, P. ;
Yan, X. B. ;
Lui, D. G. ;
Zhang, W. L. ;
Zhang, Y. ;
Ma, X. C. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) :290-298
[33]   Dental Cone-Beam Computed Tomography: Are the Eye Lens and Thyroid at Risk? [J].
Albahiti, Sarah K. ;
Jadu, Fatima M. ;
Badr, Fatma ;
Khalifa, Hanadi ;
Khan, Emad ;
Khafaji, Mawya .
INTERNATIONAL JOURNAL OF BIOMEDICINE, 2024, 14 (01) :77-82
[34]   Cone Beam Computed Tomography Imaging in Dental Implants: A Primer for Clinical Radiologists [J].
Bernaerts, Anja ;
Barbier, Lieven ;
Abeloos, Johan ;
De Backer, Tom ;
Bosmans, Frederik ;
Vanhoenacker, Filip M. ;
Casselman, Jan .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2020, 24 (05) :499-509
[36]   Is Cone-Beam Computed Tomography Always Necessary for Dental Implant Placement? [J].
Deeb, George ;
Antonos, Ludmils ;
Tack, Samuel ;
Carrico, Caroline ;
Laskin, Daniel ;
Deeb, Janina Golob .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (02) :285-289
[37]   INFLUENCE OF LEAD APRON SHIELDING ON ABSORBED DOSES FROM CONE-BEAM COMPUTED TOMOGRAPHY [J].
Rottke, Dennis ;
Andersson, Jonas ;
Ejima, Ken-Ichiro ;
Sawada, Kunihiko ;
Schulze, Dirk .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (01) :110-117
[38]   Panoramic cone beam computed tomography [J].
Chang, Jenghwa ;
Zhou, Lili ;
Wang, Song ;
Chao, K. S. Clifford .
MEDICAL PHYSICS, 2012, 39 (05) :2930-2946
[39]   ESTIMATION OF COMPUTED TOMOGRAPHY DOSE INDEX IN CONE BEAM COMPUTED TOMOGRAPHY: MOSFET MEASUREMENTS AND MONTE CARLO SIMULATIONS [J].
Kim, Sangroh ;
Yoshizumi, Terry ;
Toncheva, Greta ;
Yoo, Sua ;
Yin, Fang-Fang ;
Frush, Donald .
HEALTH PHYSICS, 2010, 98 (05) :683-691
[40]   Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery [J].
Husain, Adib Al-Haj ;
Mergen, Victor ;
Valdec, Silvio ;
Husain, Nadin Al-Haj ;
Stadlinger, Bernd ;
Essig, Harald ;
Frauenfelder, Thomas ;
Kessler, Peter ;
Lie, Suen An Nynke ;
Alkadhi, Hatem ;
Winklhofer, Sebastian .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)